Can a furnace gas valve be replaced?
replacing a furnace gas valve doesn't have to cost an arm and a leg in expensive repair bills. Repair a furnace gas valve with help from a plumbing, heating and cooling specialist in this free video clip. Bio: Tom Hutchinson currently serves as the President of Hutchinson Cape Atlantic, formerly known as Barth Plumbing.
How to fix a gas furnace that won't turn off?
Use a wire brush to clean and see if that solves it. Then place the burner correctly into the channel. The other safety trip that can cause the system to cut the gas off to the valve is the high limit switch. If the furnace runs for a few minutes, then shuts off, something could be causing the inside of the furnace to get too hot.
What should the gas valve be set at on a furnace?
The gas valve is adjustable. And usually, the installer of the equipment will dial in the outlet pressures on start-up. Because the gas valve manufacturer – Emerson, White-Rodgers, Honeywell, and other valves makers will usually have it pre-set to that 3.5″ wc, some installers forget to do this.
What should I look for when buying a new furnace?
Furnaces differ, so please check your furnace installation and service guide for your system’s specifics. This is something you don’t want to get wrong. The gas valve is adjustable. And usually, the installer of the equipment will dial in the outlet pressures on start-up.

How much does it cost to replace a gas valve on a furnace?
A furnace gas valve replacement costs $200 to $800 on average. Furnace gas valve prices are $75 to $300 for the part alone or up to $600 for original manufacturer parts (OEM). Gas valve replacement labor costs $125 to $500.
What causes a furnace gas valve to fail?
The valve itself may have simply worn out or may be damaged due to basement seepage or submersion. Alternately, one of the electronic gas ignition components or a glitch in the safety circuit may be to blame. If your furnace has a standing pilot light, the thermocouple could be worn out.
How do I know if my furnace gas valve is bad?
Here are some signs that indicate your furnace has a bad gas valve.A Gas Leak. This is a major indicator that something could be wrong with the gas valve in your furnace. ... A Total Shutdown of the Furnace. ... A Flooded Furnace. ... Get Expert Services.
How long do furnace gas valves last?
Gas Valves are routinely checked for 100,000 cycles and are used in equipment that have approximately 15 years life expectancy.
How do you fix a furnace gas valve that is stuck?
7:4711:33Fixing Stuck Gas Valve - Works Every Time | Installing propane FurnaceYouTubeStart of suggested clipEnd of suggested clipThis one isn't popping up it's supposed to push it up and it's not popping it up. So what i've doneMoreThis one isn't popping up it's supposed to push it up and it's not popping it up. So what i've done is just taken both of those plungers. Out of the gas valve assembly.
How do you reset the gas valve on a furnace?
Locate the reset button on the furnace and press it to reset the furnace. It is usually located inside the blower compartment on the side of the blower motor. Be cautious as the housing may be hot. If the button is popped up, press it down.
Can you test a gas valve?
1:125:43How to test a Gas Valve - YouTubeYouTubeStart of suggested clipEnd of suggested clipYou can set this here. And you want you should have 24 volts. Within 3 seconds 3 to 5 seconds of theMoreYou can set this here. And you want you should have 24 volts. Within 3 seconds 3 to 5 seconds of the hot surface igniter beginning to glow. If the hot surface igniter never begins to glow.
What opens gas valve on furnace?
The thermocouple (or thermopile) generates the power holds the safety valve open. Additionally, the thermocouple remains immersed in the pilot light flame. Without adequate heating of the thermocouple or thermopile, the furnace gas valve closes. As a result, this cuts off the supply of gas to the pilot light.
Are furnace gas valves universal?
Brand or Universal: The gas valve on most furnaces can be replaced with a less-expensive part from Honeywell, White Rodgers or other universal part. A few furnaces require brand parts. Lennox is one brand with higher-than-average replacement parts costs for this reason.
How much does it cost to fix a gas valve?
Gas Valve or Smart Valve If your gas valve needs to have a liquid propane valve added during installation, the price will also be higher by about $50. Universal gas valves are cheaper than brand name valves. With all this in mind, the price for a replacement job on a gas valve ranges from $195 to $870.
What does a gas valve do on a furnace?
The gas valve on your furnace is one of the most important parts. It is ultimately responsible for delivering an adjusting the flow of gas pressure to your furnace to keep it lit when running. A gas valve replacement is a common furnace repair in older furnaces or when a gas leak is present.
What happens if furnace gas pressure is too high?
High gas pressure can be just as bad for your furnace. That's because it greatly increases the risk of furnace overheating. When this happens, all manner of internal components may become damaged by the excessive heat.
How does a furnace gas valve work?
The furnace gas valve works according to the thermopile. This is the reason how the temperature remains consistent throughout the room and the home.
How long can a furnace last?
A house with a furnace is very comfortable in the winter season. But the furnace needs to be taken care of to avoid the immature wearing out of its parts. A typical furnace can be used for up to 20 years. However, after a certain point, some issues cannot be neglected. It not only affects the working of the furnace but also the power consumption at your place.
What is a thermopile in a furnace?
The thermopile is the power generator that opens the primary valve. It is the section of the valve that is submersed in the flame in the pilot light. The thermopile is supposed to be heated right to let the gas valve to stay open. If the furnace valve closes, the pilot light stops receiving gas. This is also a safety design to avoid an accumulation of gas in homes.
What is a gas chain valve?
The gas chain valve consists of the solenoid valve, the manual valve, and pilot safety. This type of valve will let you close and open the gas valve manually.
How to check a new valve?
Check the new valve by turning the gas back on. The pressure must be adequate. If not, you can rest it to get it to work.
How many units of valves make up a gas valve?
So when there is a unit that works with a gas valve, you will be able to find two units of valves that together make up the gas valve.
What is the main priority of HVAC contractors?
The main priority of our HVAC contractors is providing our customers with comfort, efficiency, and excellent service.
Who replaces gas valves in furnace?
If your furnace gas valve needs to be replaced, I recommend hiring an HVAC contractor to do it for you.
What is the purpose of the gas valve manifold in a furnace?
The gas valve manifold inside the furnace opens and closes to allow your furnace to burn gas to create heat.
How many volts should a furnace ignitor be?
Observe your furnace. After the ignitor turns on, then you should read around 24 or 120 volts on your multimeter (it could be 24 or 120 volts, depending on your furnace)
What happens if gas valve opens up?
If your gas valve opens up after hitting it, then you’ll get heating for a while.
What is a gas shut off dial?
Most gas valves in furnaces have a manual shutoff dial or switch. This shutoff allows you to disable the gas valve inside the furnace.
Home Repair
Recall the original problem where some modules in the house were not properly...
Home Repair
Since it is too hot to play outside I was stripping some wire in recycle box. It...
Home Repair
Do you have a diagram to reattach a chain on Tecumseh snowblower? I need a...
Appliances
Assembling the bits for my wildlife pond project, I have bought a load of slate...
Can you modify gas?
With gas you don't want to take chances "modifying" anything.
Can you replace a valve that has been damaged?
damage to the valve, you'd be much safer replacing the valve.
Can you open a valve manually?
open the valve manually in the event of a power failure. You could
Can Trane parts interchange?
Trane parts don't interchange with other brands , so that may be a concern.
Can you degauss a valve upside down?
do fine. Just remembe to degauss the coil if you install the valve upside
Does Trane make gas valves?
But Trane doesn't make the gas valve anyway. And it's not proprietary
Why does my furnace cut off gas?
The other safety trip that can cause the system to cut the gas off to the valve is the high limit switch. If the furnace runs for a few minutes, then shuts off, something could be causing the inside of the furnace to get too hot. The first thing I would check is to see is if the evaporator coil is dirty. I have a great video that shows what a dirty evaporator coil looks like and what it takes to clean it.
Why does my gas valve drop out after burning?
Another reason the flame could drop out after only a few seconds of burning is the flame sensor. If the sensor doesn’t detect the flame, the control board will signal the gas valve to shut down.
How much natural gas can pass through a furnace manifold?
Only a certain amount of gas can be allowed to pass through the manifold and on to the burners. The manufacturer of the furnace determines what that will be. It is pretty standard, though—about 3.5″ water columns (wc). The natural gas pressure coming from the street is somewhere around 7″-10″ wc, but the gas valve itself specifically allows that 3.5″ wc onto the burners.
How many volts does a furnace inducer motor use?
When a furnace begins a new cycle, the inducer motor is the first thing you should see kick on. One hundred twenty volts are applied through the wires coming from the control board. This starts the inducer motor for up to 60 seconds before anything else even happens.
Why does my furnace have condensation?
If the gas pressure is too low, your furnace’s efficiency will go down. More condensation than usual will build up because the air in the air-fuel mixture will be too high. The condensation can cause corrosion, possibly creating the need for a heat exchanger replacement in the future.
What is a flame sensor?
The flame sensor senses whether the flame is correctly burning. At the opposite end of the burner assembly, the flame sensor also stands in the way of the flame. The rod, which should be cleaned annually, by the way, will heat up and send a millivolt signal down to its ceramic base and on to the control board.
What is the first thing you should see when a furnace starts a new cycle?
When a furnace begins a new cycle, the inducer motor is the first thing you should see kick on. A safety device called a pressure switch activates when the diaphragm inside it recognizes the suction or purging action of the inducer motor. Next, the three parts of the ignition sequence begin.
What happens if you crack a gas valve?
Once you crack open a gas valve, it is deemed kapoot. No rebuilding and no re-gasketing, simply scrap. Loses the UL listing, too.
Does a heating system have a useful life expectancy?
The only thing he should have noted was The heating system has passed its useful life expectancy. Strongly advice a Licensed and insured Heating contractor do a through inspection!
Can you get an OEM valve for a 3 wire pilot?
I would call in a Pro, we carried the universal valves to replace most of those intermittent spark systems. If you have the 3-wire pilot assembly then your technician should be able to get an OEM valve from Carrier, they are still available.
Is HVAC talk a DIY site?
Welcome to HVAC-Talk. com, a non-DIY site and the ultimate Source for HVAC Information & Knowledge Sharing for the industry professional! Here you can join over 150,000 HVAC Professionals & enthusiasts from around the world discussing all things related to HVAC/R. You are currently viewing as a NON-REGISTERED guest which gives you limited access to view discussions
Can you call in a pro to get a new gas valve installed?
Only advise we can give you is call in a PRO and get a NEW gas valve installed, and while the tech is there have him/her remove that flexible gas pipe and hard pipe it out of the furnace, then re-connect the flex pipe. This has DIY written all over it so high probability this thread will be closed by the moderators. GOOD LUCK

Working of The Valve
- You should know that there are only specific types of boilers and furnaces that work with the gas valves. So when there is a unit that works with a gas valve, you will be able to find two units of valves that together make up the gas valve. The pilot light uses the primary light for gas supply and the burner trays receive gas from the secondary valve which is also called the main valve. T…
Know Your Gas Valve Type
- The two types of gas valves that you can find in the different units of furnaces are gas chain valves and combination valves. 1. The gas chain valve consists of the solenoid valve, the manual valve, and pilot safety. This type of valve will let you close and open the gas valve manually. 2. The combination gas valve though does not require all the different valves in the gas chain valve an…
Troubleshooting Tips For Gas Valves
- The pilot light should always be on. If it is not, you will need to light it up. For this, you can follow the manual that might have been provided to you. Or you can always call us to know more.
- You will have to wait for a little while for the second valve to open as it needs adequate power from the pilot light.
- The pilot light should always be on. If it is not, you will need to light it up. For this, you can follow the manual that might have been provided to you. Or you can always call us to know more.
- You will have to wait for a little while for the second valve to open as it needs adequate power from the pilot light.
- The thermopile should be producing an adequate voltage for the primary valve to stay open. There is a definite need for a replacement if the voltage is not enough.
- In case you would like to know an estimate of the cost of replacement, let us know. We will be happy to help you.
Maintenance
- A house with a furnace is very comfortable in the winter season. But the furnace needs to be taken care of to avoid the immature wearing out of its parts. A typical furnace can be used for up to 20 years. However, after a certain point, some issues cannot be neglected. It not only affects the working of the furnace but also the power consumption at your place. While the furnace mig…
The Necessary Types of Equipment Required
- If you need to figure out if the gas valve requires replacement then you can contact us for more information. If you have figured out that your valve requires replacement then you can proceed further. You can always contact us for any assistance needed anywhere in the process. Here are the things that you will be needing for the replacement: 1. A basic toolkit 2. The accurate valve t…