Centrifuge the tube for 10 minutes at 3400 rpm. Remove the tube carefully without disturbing the contents. Do you have to spin lavender tubes? EDTA
Ethylenediaminetetraacetic acid
Ethylenediaminetetraacetic acid, also known by several other names, is a chemical used for both industrial and medical purposes. It was synthesized for the first time in 1935 by Ferdinand Münz.
What is in a lavender top tube?
Lavender-top tube: Contains K 2 EDTA. Use: EDTA whole blood or plasma. Send plasma in a plastic transport tube labeled “Plasma, EDTA.” Send whole blood in a lavender-top tube. Gray-top tube: Contains sodium fluoride (a preservative) and potassium oxalate (an anticoagulant).
How long should I spin my tubes in the centrifuge?
Centrifuge for the preprogrammed time or 10 minutes for red or gold top tubes, 10 minutes for green, and 15 minutes for BD Blue top tubes. If minimum g-force (1300g) cannot be achieved, spin for 20 minutes. Do not use a manual brake on the centrifuge.
How to use a centrifuge for the collection of blood?
Place the collection tube in the upright position in the rack, and allow the blood to clot at room temperature for 30 to 60 minutes. If clotting fails to occur within 60 minutes, notify the physician. Do not remove the tube stopper. 3. After allowing clot to form, insert the tube in the centrifuge, stopper end up. (See Figure 8.)
How do you use a balance tube in a centrifuge?
When using a bench-top centrifuge, employ a balance tube of the same type containing an equivalent volume of water. Do not exceed 10 minutes of spin time unless otherwise specified. Turn the centrifuge off, if not an automatic turn off, and allow it to come to a complete stop.

Which color tubes do you centrifuge?
Red Top Tubes Centrifuging the specimen yields serum. NOTE: All drug levels must be drawn in red top tubes only.
Do you centrifuge all tubes?
All specimens collected in tubes with gel barriers should be properly centrifuged prior to transport. When gel tubes are stored after centrifugation, the serum/plasma is separated from the cells by the gel barrier.
Which blood tubes do you spin?
Spin 10-15 min The ORANGE, LT GREEN and PEARL tubes can be centrifuged immediately. Remember to invert the LT GREEN & PEARL tubes 8-10 times after collecting to make sure the anticoagulant prevents the blood from clotting.
What is the lavender top used for in phlebotomy?
Lavender Top Tube: This tube is used to for Hematology (CBC, e.g.) and certain Chemistry and Blood Bank testing. The tube contains EDTA as an anticoagulant. Samples collected in lavender tubes may not be used for coagulation tests. Light Blue Top Tube: This tube is used for coagulation testing.
How many times do you invert a lavender top tube?
Lavender LAV - 4 ml. K2EDTA Routine hematology procedures Immediately after collection, invert the tube 8-10 times to mix anticoagulant.
Do you spin blue top tubes?
Centrifuge for the preprogrammed time or 10 minutes for red or gold top tubes, 10 minutes for green, and 15 minutes for BD Blue top tubes. If minimum g-force (1300g) cannot be achieved, spin for 20 minutes. Do not use a manual brake on the centrifuge.
Do lavender blood tubes get spun?
It is recommended that these tubes are centrifuged after the clot forms and the serum transferred to a separate container. This new container should be labeled with owner name, animal ID, and as serum.
Are pink and lavender tubes the same?
What are the differences between the lavender stopper and the pink stopper BD Vacutainer K2EDTA Tubes? A. The differences are the types of closures and the labelling. The lavender stopper can either be rubber or a Hemogard™ closure on a plastic tube.
Do you spin a tiger top tube?
A serum separator tube (SST, tiger top tube). Let the blood sit for 30 minutes to one hour at room temperature to clot before spinning and separating. A delay in centrifugation may have a detrimental effect on the sample quality and may result inaccurate results. Avoid hemolysis.
What is the lavender top tube used for?
Lavender-top tube (EDTA) This tube contains EDTA as an anticoagulant - used for most hematological procedures. These tubes are preferred for molecular tests.
What is in a lavender top tube?
Lavender top tubes. Contain anticoagulant Ethylendiaminetetraactic acid (EDTA) to prevent clotting. Are used mostly for hematology studies. Must be completely filled to assure a correct anticoagulant to blood ratio. Must be inverted after filling to assure proper mixture of anticoagulant with blood.
How long is blood in a lavender tube good for?
Tubes of blood are to be kept closed at all times. 2. Whole blood samples should not remain at room temperature longer than 8 hours. If assays are not completed within 8 hours, samples should be stored at +2°C to +8°C no longer than 7 days.
What tubes are used in a centrifuge?
Centrifuge tubes are available in an array of materials such as polypropylene (PP), polyallomer (PA), polycarbonate (PC), and polyethylene terephthalate (PET). PP is a popular type of tube due to its ability to be used for high speed applications, is autoclavable, and is resistance to most organic solvents.
Do you centrifuge light blue tube?
Immediately after drawing, gently invert the tube 4 times to activate the anticoagulant and prevent clotting. Do not centrifuge.
Why do they spin test tubes?
Blood-spinning is a medical procedure used to shorten the healing time of an injury. Small samples of the patient's blood are taken and spun in a centrifuge, allowing platelets and blood plasma to be isolated from other blood components.
Why are centrifuge tubes used?
Centrifuge tubes are used to contain liquids during centrifugation, which separates the sample into its components by rapidly rotating it around a fixed axis. Most centrifuge tubes have conical bottoms, which help collect any solid or heavier parts of the sample being centrifuged.