- Move toggle switch located on the bottom of actuator to the OFF (center) position. ...
- Unscrew (counterclockwise) the locking knob above the handle four (4) full turns.
- Push down on the locking knob (not the handle). ...
How do you mount a JVA on a Jandy valve?
JVA’s mount directly on all full-size JandyPro Series Valves (8 screws on lid). Zodiac recommends motorizing Jandy Pro Series Never Lube®Valves only. JVA’s may be mounted onto valves in any of the four (4) positions in Figure 3.
Do I need to adjust the actuator cams on a Jandy valve?
NOTEIf the valve(s) are plumbed with port B as the common port (Standard Plumbing) and the main body of the actuator(s) are mounted over port B (Standard Mounting), there is no need to adjust the actuator cams. Jandy®Pro Series Valve Actuator | Installation and Operation ManualENGLISHPage 5 3.2 Actuator Mounting
How do I attach the actuator to the valve?
Place the actuator onto the valve. 5. Rotate the actuator while keeping the two shafts engaged until the screw holes on the actuator legs align with the empty screw holes (from step 2) in the valve (see Figure 6). 6. Use the four (4) large 2" Phillips head screws (included with the JVA) to secure the JVA to the valve.
How to fix a pool/spa actuator motor that won't turn?
Lubricate valve. Remove actuator and valve lid and inspect. Actuator motor works but the valve diverter does not turn. NOTEOn a pool/spa combination, the problem would be spa draining or overflowing. A). Actuator shaft broken. B). Valve diverter broken. C). Actuator in manual position. D). Gear train damaged. A). Replace actuator shaft.

How do I adjust my pool actuator valve?
4:569:27How to Adjust Jandy Automatic Actuator Valve Cam's - YouTubeYouTubeStart of suggested clipEnd of suggested clipThe back the back processor. Then you flip it around the back switch is located right underneathMoreThe back the back processor. Then you flip it around the back switch is located right underneath here they asked three positions.
How do I adjust my pool valve actuator manually?
0:062:53Pool Valve Actuator Manual Mode & Manual Override part 1 of 2YouTubeStart of suggested clipEnd of suggested clipThe valves. And there's a switch on back on one which is usually the program office in the middleMoreThe valves. And there's a switch on back on one which is usually the program office in the middle and this is where you want to switch. When you do the manual mode with the knob.
How do I set my Jandy actuator?
0:2711:49How to set/orient valve actuators for pool mode and spa mode - YouTubeYouTubeStart of suggested clipEnd of suggested clipSo you open it up. And you'll see the cord wrapped around the top. This is the jandy actuator rightMoreSo you open it up. And you'll see the cord wrapped around the top. This is the jandy actuator right here. And what you're gonna find is that um there is a little switch on the bottom of this actuator.
How do you manually turn a Jandy valve actuator on?
Move the toggle switch to either ON 1 or ON 2. Allow the actuator shaft to move until it stops. Check valve diverter position*, if the position is correct flip the toggle switch in the opposite direction and allow the shaft to stop again.
What position should my pool valves be set?
0:532:40How to: Pool Valves - YouTubeYouTubeStart of suggested clipEnd of suggested clipAlso if your pool has a spa bat valve should generally be set at a 45 degree angle to give justMoreAlso if your pool has a spa bat valve should generally be set at a 45 degree angle to give just enough flow to the spa for circulation.
Can you manually turn Jandy valve?
There are two (2) methods of manually rotating the JVA; one with power on (system operational) and one with power off (no power to the control system). 1. Move the toggle switch located on the bottom of the actuator to the opposite position (ON 1 switch to ON 2 or vice versa).
How does a pool valve actuator work?
What is a Pool Valve Actuator? Pool valve actuators provide an automated command by push-button that goes to one of the diverter valves or more in the pool's water flow system. You will find it on your pool's diverter valve and it will be wired in the pool's control box.
How does a valve actuator work?
Torque is the rotational force an actuator generates to close a rotational valve. Electric actuators can generate this force by transmitting it to the output shaft and then the valve stem. When pressure is applied to the valve stem, the valve's orifice opens or closes.
How do I program my Jandy Aqualink RS?
Basic Programming: To set a particular piece of equipment to turn on and off at a predetermined time, press the MENU button, press the forward arrow button to scroll to the PROGRAM menu, press ENTER, and then press the button for the equipment that you want to program.
How does a two way Jandy valve work?
Jandy 2-Way Valves On a two port Jandy valve, the valve has two closed positions and one open position. On the left, the valve is closed because the diverter is blocking the flow of water through the port. In the center, the diverter is blocking nothing, so the valve is open and water can flow through it.
Why is my actuator not working?
Some common valve issues that can cause actuator problems: A worn out valve stem. Seized up packing. An obstruction.
How does a 3 way pool valve work?
1:093:05Understanding the three-way valve - YouTubeYouTubeStart of suggested clipEnd of suggested clipIt's literally a gate that closes that part of the valve. And the other to stay open therefore. OnlyMoreIt's literally a gate that closes that part of the valve. And the other to stay open therefore. Only water being pulled from the drain going towards the pump. And if you turn it the other way.
How often should I lubricate a pool valve diverter?
Since the actuator rotates the valve diverter which redirects the flow of water, it is imperative that the seals and the O-rings within the valve body be lubricated often (at least every three (3) months). Use the following procedure to lubricate the valve diverter seals: 1. Turn off all pool/spa equipment. 2.
How many seals does a JVA actuator have?
6.1 Actuator. The JVA has three (3) seals which should be lubricated once a year. One o-ring is located on the bottom of the actuator where the plastic shaft exits the housing and two (2) O-rings located in the top cover near where the shaft exits the top of the housing.