Measure the length of the duct--in inches--and multiply that measurement by the length of the perimeter of the duct. This will tell you how many square inches are in the duct area. Divide this result by 144, the number of square inches in a square foot. This will tell you how many square feet are in the duct area.
- Round: Area = Pi * (D / 12) * L.
- Rectangular: Area = (W * 2 + H * 2) / 12 * L.
- Flat Oval: Area = (Pi * H + 2 * W) / 12 * L.
How do you calculate duct size?
- Square footage of your home
- Square footage of each room in your home
- Cubic feet per minute (CFM)
- Friction loss rate of ductwork
How do you calculate square footage of metal roofing?
How Do You Figure Square Footage Of A Metal Roof? Multiply the roof’s length by the width to figure out how much room the roof has available between the treads.The surface area if the length is 21 feet and the width is 10 feet is 210 square feet — 210 times 10 equals 21.
How to calculate the square feet of odd shapes?
How to Calculate the Square Feet of Odd Shapes
- Measure all the dimensions or sides of the area.
- Draw the area on graph paper using the measurements you obtained. Make sure your drawing is to scale.
- Divide the drawing into shapes. ...
- Figure the area of each shape. ...
- Add the areas of all the individual shapes to find the total square footage.
How to calculate square feet using one easy formula?
- Divide the space into smaller sections.
- Measure each section separately and calculate the square footage of each.
- Use a calculator to add the numbers together to get the total square footage.

How do you calculate ductwork?
To calculate the required equipment size, divide the HVAC load for the entire building by 12,000. One ton equals 12,000 BTUs, so if a house or office needs 24,000 BTUs, it will take a 2-ton HVAC unit. If you get an uneven number, such as 2.33 for a 28,000 BTU load capacity, round up to a 2.5-ton unit.
How many CFM is a 20x20 duct?
2,000 CFMCFM Sizing Chart For Metal Round Ducts (50-2,000 CFM)Duct Size (Inches)Metal Duct Airflow (CFM)14 inches750 CFM16 inches1,200 CFM18 inches1,500 CFM20 inches2,000 CFM7 more rows
How do you calculate the area of AC ducts?
Measure the distance across the duct, in inches, then multiply by 3.14159 if the duct is circular to find its circumference, in inches. Then, measure the length of the duct--in inches--and multiply by the circumference. This is the number of square inches in the duct area.
What is the good rule of thumb in sizing ductwork?
In the simplest of terms, the rule of thumb states – for every 500 square feet of air-conditioned floor area install an AC of one-tonne capacity. Why Does Duct Size Matter? One thing pretty clear is that you need to have appropriately sized ducts for the HVAC to work effectively.
What size duct do I need for 2000 CFM?
2000 cfm (0.94 m3/s) of air flows through a 10 x 12 inches rectangular duct.
How many square inches are in a 6 inch round duct?
Calculating Venting Area For instance, 6-inch round duct has a venting area of roughly 28 square inches.
How is rectangular duct measured?
If you have round ducts, you simply measure the diameter (D) of the duct (the cross-section). This will tell you what size duct to purchase to replace it. If you have rectangular or square ducts, measure the width (W) and height (H) of the duct and use these figures when buying new parts.
Is standard for ducting measurement?
For Semi-rigid Ventilation hccting The steel wire used in the spiral for 900, 760 and 600 mm diameter ducting shall have a minimum diameter of 5.38 mm and in all other sizes, a minimum- diameter of 3.25 mm.
What size duct is needed for 1200 CFM?
10” diameterThe higher the cubic feet per minute, the larger the duct you'll need. At 600 CFM, the minimum duct size is 6”. At 900 CFM, the minimum duct size is 8”. Finally, at 1200 CFM and above, consider a 10” diameter duct or larger.
Does duct length affect CFM?
Excessive Length Longer ducts can increase the size of the air handler needed to supply the same cubic feet per minute (cfm), or the HVAC system may not be able to supply the designed cfm to all locations.
How many CFM is a 3-ton AC?
1200 CFMA 3-ton heat pump has approximately 1200 CFM of air flow.
How many CFM do I need for a 12x12 room?
One cfm per square foot of floor area is the average air quantity required for a room or entire building.
How does the size of ductwork affect the comfort of a home?
The size of your ductwork can massively alter the comfort of your home —and the amount you spend every month to keep your house heated or cooled. HVAC units represent the largest portion of your home’s energy use, so getting those numbers right is imperative in order to save the most money on utility bills.
What happens if you install a duct size too small?
Install duct sizes that are too small, and your system will have to work harder to keep your home heated and cooled. If your duct sizing is too big, the velocity will be compromised, meaning you may not be able to feel it through the air vents.
What is the CFM of a room?
Next, we need to talk about the cubic feet per minute, or CFM. This measurement indicates the air velocity or flow needed to accurately heat or cool a room. Since the size of your ductwork can increase or lower this measurement, you’ll have to find the necessary CFM for each room before you can get the right duct size for each space.
How to calculate CFM?
To calculate CFM, you need to know the size of your heating or cooling unit in tons. Multiply this number by 400, which is the average output of an HVAC unit. Then divide by the total square footage of your home. This will give you the multiplier for all your rooms’ CFM.
Why is HVAC more accurate than handyman?
Because an HVAC professional has access to more sophisticated tools, it’s a safe bet that their calculations will be a little bit more precise than a home handyman’s .
How to calculate duct area in square feet?
Duct areas in square feet can be calculated by using geometry rules for round areas. The area will cover a two-dimensional slice of the duct. To then convert that to volume, you multiply the resulting area by the length.
How to measure duct length?
Measure the length of the duct in feet (if you want to translate the two-dimensional area to the three-dimensional volume), then multiply the area by the length. Continuing this example, for a 10 foot duct the area is 23.9 feet.
How to find radius of duct?
Divide the diameter by 2 to get the radius of the duct.
How to find the square of a radius?
Multiply the radius by itself to get the square of the radius. For instance, if the radius is 10 inches, the square of the radius is 100.
How to find the size of a duct?
With a ductulator, all you have to do is mark the friction loss at 0.1 in.wg per 100 ft (0.816 Pa per meter) and then rotate your airflow until it aligns with the marked friction loss (blue color section). Then, you see the bottom part of the ductulator to find the rectangular duct size (green color section).
How are HVAC ducts sized?
HVAC ducts are sized based on the required airflow. Ducts have different forms and shapes with different dimensions. So, how do you size a duct? And, how do you know which duct size is the best one?
How to Find the Best Duct Size?
Whether you are using a physical ductulator or software, you’ll need to manually calculate and compare the duct area of the sizes you’ve selected to find the most cost-optimized sizes.
How thick is fiberglass insulation?
Most air conditioning ducts use fiberglass insulations while some of them use polyethylene (PE) insulations. For fiberglass insulated ducts, you need to add either 1″ (25mm) or 2″ (50mm) depending on the project specification. Usually, AHUs have 50mm thick insulation while FCUs have 25mm thick insulation.
How thick is a duct insulation?
These internal duct insulations are usually 50mm thick.
How wide should a duct be?
Generally, you want to keep the duct ratio not more than 1 to 4. Duct ratio is the ratio between the width and the height of the duct. If the height of a duct is 12″ (300mm) then its width should not exceed 48″ (1200mm).
Why is a duct ratio of 1:4 not efficient?
Ducts with a duct ratio of more than 1:4 are not efficient due to high friction loss. However, you may use a greater duct ratio as long as your fan has sufficient static head.
How to find the area of a duct?from hunker.com
Multiply the square of the radius by 3.14 to get the area of the duct in square inches. In this example, the area is 314 square inches.
How is duct size determined?from hunker.com
Duct size is determined by the velocity of airflow needed to supply the part of the building the duct is servicing. Airflow is measured in cubic feet per minute (CFM), but duct dimensions are typically measured in inches, which calls for a conversion factor to convert a cross-sectional area from square inches to square feet. Even though most pros and homeowners routinely refer to charts rather than doing the calculations themselves, it's good to know this conversion factor and how to use it.
What is duct CFM chart?from servicetitan.com
Refer to the duct CFM chart in the HVAC manufacturer’s specs to determine the external static pressure of the blower for that specific HVAC model. It’s typically displayed as a CFM chart for HVAC that breaks down different blower settings and total CFMs required for the house or building.
How to determine friction rate?from servicetitan.com
It’s calculated by using the available static pressure (ASP) divided by total effective length (TEL) and multiplied by 100 to show how much pressure drop the system can accommodate per 100 feet of effective length. You want a higher friction rate, because it means you can use smaller, more restrictive ductwork than on an HVAC project designed with a lower friction rate, which requires larger ducts. With a low friction rate, one faulty component can severely hamper air flow because there’s less room for error.
Why are HVAC ducts sized?from hunker.com
HVAC ducts must be sized accurately to deliver the airflow needed for effective heating and cooling. Ducts with a cross-sectional area that is too small won't provide enough air, while those with an area that is too large will cause your HVAC equipment to overwork and wear out more quickly.
What happens if you use the wrong size duct?from servicetitan.com
Using the wrong size duct for the space can prematurely wear out HVAC components and will likely increase customers’ energy expenses. Incorrect duct size can also cause inadequate airflow to certain areas and produce unwelcome noise. None of those scenarios result in happy customers after they’ve paid big bucks for a new, more efficient HVAC system or upgraded ductwork.
How much air is needed to heat a room?from servicetitan.com
TIP: Approximately 1 CFM of air is required to heat or cool 1 to 1.25 square feet of floor area. It takes closer to 2 CFMs to cool rooms with a lot of windows or direct sunlight.
What is duct size calculator?
A duct size calculator, commonly known as a ductulator, depends on factors like the size of the space you’re heating or cooling, air flow velocity, friction loss, and available static pressure of the HVAC system. Save time on the job and do less manual math by using our free, online ServiceTitan Ductulator to easily calculate the right size duct for your projects.
How to calculate the area of a square room?
To calculate the area of a rectangular or square room, simply multiply the length and width of the room. You can also refer to a building’s blueprint, zoning drawings on file with the local planning office, or a recent real estate listing for the space, if available.
What is duct CFM chart?
Refer to the duct CFM chart in the HVAC manufacturer’s specs to determine the external static pressure of the blower for that specific HVAC model. It’s typically displayed as a CFM chart for HVAC that breaks down different blower settings and total CFMs required for the house or building.
How to determine friction rate?
It’s calculated by using the available static pressure (ASP) divided by total effective length (TEL) and multiplied by 100 to show how much pressure drop the system can accommodate per 100 feet of effective length. You want a higher friction rate, because it means you can use smaller, more restrictive ductwork than on an HVAC project designed with a lower friction rate, which requires larger ducts. With a low friction rate, one faulty component can severely hamper air flow because there’s less room for error.
What is the average airflow output in cooling mode?
NOTE: The average airflow output in cooling mode is between 350 and 400 CFM. Heating season airflow requires approximately 65 percent of the airflow needed for cooling. Therefore, to ensure there’s adequate airflow for both cooling and heating, use the high-end threshold of 400 CFM when referencing a duct sizing chart CFM resource.
What happens if you use the wrong size duct?
Using the wrong size duct for the space can prematurely wear out HVAC components and will likely increase customers’ energy expenses. Incorrect duct size can also cause inadequate airflow to certain areas and produce unwelcome noise. None of those scenarios result in happy customers after they’ve paid big bucks for a new, more efficient HVAC system or upgraded ductwork.
How many BTUs does a 2 ton furnace need?
As an example, say Room A needs 2,000 BTUs of heat gain based on HVAC room-by-room load calculations, and the home overall needs 24,000 BTUs, which requires a 2-ton furnace with a velocity of 800 CFM.
How to measure area of a rectangle?
If you are measuring a square or rectangle area, multiply length times width; Length x Width = Area.
What is square meters?
Square meters is also a common measure of area. Assume you have a rectangular area such as a room and, for example, you want to calculate the square footage area for flooring or carpet.
How to convert inches to feet?
If you measured in another unit of measure, do the following to convert to feet. - inches: divide by 12 and that is your measurement in feet. - yards: multiply by 3 and that is your measurement in feet. - centimeters: multiply by 0.03281 to convert to feet. - meters: multiply by 3.281 to convert to feet.
How is duct size determined?from hunker.com
Duct size is determined by the velocity of airflow needed to supply the part of the building the duct is servicing. Airflow is measured in cubic feet per minute (CFM), but duct dimensions are typically measured in inches, which calls for a conversion factor to convert a cross-sectional area from square inches to square feet. Even though most pros and homeowners routinely refer to charts rather than doing the calculations themselves, it's good to know this conversion factor and how to use it.
How to Find the Best Duct Size?from aircondlounge.com
Whether you are using a physical ductulator or software, you’ll need to manually calculate and compare the duct area of the sizes you’ve selected to find the most cost-optimized sizes.
What is the outer shell of a straight duct?from spotusa.com
The outer metal shell of straight duct may be spiral flat oval lock-seam duct or longitudinal-seam welded duct. We make 516 spiral flat oval duct sizes that can be used for double-wall construction, excluding only the 3” and 4” minor axis duct sizes. We make double-wall flat oval duct with outer shell dimensions ranging from 13 x 5 to 124 x 36. Standard construction and gauges are in accordance with SMACNA standards for +10” WG. Fittings can be made with either fully-welded construction or “tack-welded-and-sealed” construction.
Why is a rectangular duct not recommended?from spotusa.com
That’s because rectangular ducts are not recommended to be used over 2000 FPM velocity. Those square corners in rectangular duct cause far more turbulence than the rounded profiles of round and flat oval duct, and turbulence increases dynamic pressure losses and noise.
How does ASP affect HVAC?from servicetitan.com
ASP impacts HVAC ductwork sizing. The less static pressure available, the larger the ductwork required. If projected velocity seems too high for the system, select the next-largest duct size.
How much does a Class A duct leak?from spotusa.com
Let’s not forget the cost of the duct leakage. A rectangular duct system sealed to Class A standards is expected to leak 6 CFM/100 ft.2 of duct surface at 1” WG. A flat oval duct system sealed to Class A is expected to leak 2 CFM/100 ft.2 of duct surface area. For a 2.0” WG system, that is 9.4 CFM/100 ft.2 and 3.1 CFM/100 ft.2 respectively. At a system leakage cost estimate of $1.75/CFM/year ‡ the payback versus lined rectangular duct is less than seven years ‡‡. It’s immediate when compared to double-wall rectangular.
What is inner metal duct?from spotusa.com
The inner metal shell may be spiral flat oval lock-seam duct or longitudinal-seam welded duct. They are available as solid metal, perforated metal (23% open area), and perforated metal with Mylar erosion barrier. Inner metal shells are available in the same materials as the outer shells. The function of the inner shell is to contain the insulation liner material and maintain the cross-sectional profile of the airstream. It is not the “pressure shell”. Unless specifically ordered, standard construction is to tack-weld all seams except the spiral lock-seams, and omit sealing. Spiral flat oval lock-seam duct is provided corrugated to increase rigidity.