Knowledge Builders

how do you clean a catalyst dx

by Abdul Beer Published 2 years ago Updated 1 year ago
image

To Clean the Internal Components 1. On the Catalyst Dx* touch screen, tap Toolsand then tap Clean Analyzer.

To Clean the Internal Components
On the Catalyst Dx* touch screen, tap Tools and then tap Clean Analyzer.

Full Answer

How do I clean the catalyst DX analyzer?

It is recommended that you wear clean powder-free latex or nitrile gloves when cleaning the internal components of the analyzer. Wearing clean latex gloves helps to avoid smudges on the components and ensures an effective cleaning. IMPORTANT: • Never use canned air in or around the Catalyst Dx analyzer.

How do you clean a catalytic converter?

To clean a catalytic converter, start by choosing a commercial cleaner made specifically for your car's engine type. Then, pour the cleaner into the gas tank and drive your car to run the cleaner through the catalytic converter.

Can you run untreated whole blood on catalyst DX analyzer?

You can run untreated whole blood, lithium heparinized whole blood, plasma, serum, and urine samples on the Catalyst Dx analyzer. IMPORTANT:Do not use EDTA or sodium heparin for chemistry analysis. To Prepare an Untreated Whole Blood Sample (Using a Lithium Heparin Whole Blood Separator)

How do I run quality control (QC) on catalyst DX?

Tap the quality control lot number you are using and tap Run QC. 6. Tap the QC information in the Pending list on the Catalyst Dx Home screen and then tap Load. 7. If you are running VetTrol Control, follow the on-screen instructions for loading the quality control materials and then tap Run.

image

How do you clean one catalyst?

1. Tap the Catalyst One icon on the IDEXX VetLab Station Home screen. 2. Tap Maintenance, tap Clean, and follow these on-screen instructions.

How do I run a QC on a catalyst DX?

0:362:09How to Run Quality Control (QC) on the IDEXX Catalyst Dx® Chemistry ...YouTubeStart of suggested clipEnd of suggested clipThe quality control lot number you are using and tap run QC tap the QC information in the pendingMoreThe quality control lot number you are using and tap run QC tap the QC information in the pending list on the catalyst TX analyzer home screen and then tap load.

What is Catalyst Dx?

This catalyst analyzer is used to test serum chemistry, electrolytes, SDMA, urine, phenobarbital and fructosamine levels; as well as many other hemaology tests you may find necessary for patients. It saves time with it's automated pipetting and blood separation.

How do you calibrate a catalyst one?

0:571:55How to Run Quality Control (QC) on the IDEXX Catalyst One ... - YouTubeYouTubeStart of suggested clipEnd of suggested clipFill the pipette tip section of the drawer load a sample cup containing three hundred microliters ofMoreFill the pipette tip section of the drawer load a sample cup containing three hundred microliters of properly prepared control fluid in the sample cup holder load.

How do you clean SediVue DX?

On the SediVue Dx Settings screen, tap Clean and then tap Turn Off SediVue. 4. Using a new rinsed alcohol prep pad, clean the left side of the pusher arm 5 times (ensuring the right edge of the track is cleaned thoroughly), and then dry it with a new dry optical tissue.

How do you dilute SediVue urine?

Mix the sample and run the undiluted, neat sample on the SediVue Dx analyzer. Dilute 1 part urine with 4 parts 0.9% normal saline (1:5).

Is a chem 7 the same as a basic metabolic panel?

CHEM-7 is a group of blood tests that provides information about your body's metabolism. The test is commonly called a basic metabolic panel.

What does a Chem 10 include?

The chem-10 consisted of blood urea nitrogen, creatinine, sodium, potassium, chloride, carbon dioxide (sometimes called bicarbonate), glucose, calcium, magnesium, and … ta-dah! phosphate!

How do you dilute idexx catalysts?

Accurately measure the desired amount of sample to be diluted and gently transfer it to a sample cup. Then, accurately measure an equal amount of diluent (0.9% saline) and transfer it to the sample. 2. Thoroughly mix the sample and diluent, ensuring there are no bubbles in the mixed sample.

How do you use phenobarbital on a Catalyst?

0:371:24How to Run a Phenobarbital (PHBR) Test on the IDEXX Chemistry One ...YouTubeStart of suggested clipEnd of suggested clipIt's time to load the materials. Into the catalyst one analyzer first ensure the pipette tip area ofMoreIt's time to load the materials. Into the catalyst one analyzer first ensure the pipette tip area of the drawer is full next load the sample. Then load the phenobarbital.

What is a catalyst Chem 10 clip?

Chem 10 CLIP A focused chemistry foundation; combine with a CBC, electrolytes, and other tests. Use albumin level to guide safe administration of anesthesia. Order now. ALB. ALB/GLOB.

How do you change a ProCyte stain pack?

To change the stain pack: 1. Either tap Change Stain in the alert message or tap the ProCyte Dx icon on the Home screen and then tap Change Stain. 2. Scan bar code #2 on the new stain pack box and tap Continue.

Where are the status messages on a Catalyst DX?

Status messages are displayed in two different locations on the analzyer. Some are reported in the center display area on the Catalyst Dx Home screen. Others appear in the status bar at the top of the screen. These messages provide information on the current state of the analyzer.

How many microliters of serum is needed for a catalyst?

When using a Catalyst Sample Cup, 300 microliters of serum or plasma will allow you to run most test combinations. The following table provides general guidance for tests that do not include a reagent consumable. Refer to applicable quick reference guides for test-specific sample type and volume requirements.

What is the DX analyzer?

The Catalyst Dx analyzer uses dry-slide technology—the most accurate technology available for in-house testing . Dry-slide technology uses layers to minimize impurities for the most accurate results from even compromised samples.

How long should you wait to run a QC clamp?

It is recommended that you wait at least 30 minutes after running any slides before running the QC CLIP.

Can you print Catalyst DX results?

The Catalyst Dx analyzer is connected to the IDEXX VetLab Station. Therefore, you print your Catalyst Dx test results using the print settings on the IDEXX VetLab Station (compati ble printer required). For more information on printing from the IDEXX VetLab Station, see the IDEXX VetLab Station Operator’s Guide.

Is the Catalyst DX analyzer redesigned?

Note: Some of the components on the Catalyst Dx analyzer have been redesigned since the analyzer was originally launched. The images in this section show the new hardware designs (for example, a single tip/diluent drawer).

What to do if check engine light returns?

If the light returns, take your car to a licensed mechanic immediately to diagnose any underlying problems or replace a failed converter. The mechanic can recommend replacing ...

How much does a car scanner cost?

Some scanners are made to work only with specific makes! Scanners have become very inexpensive in the last few years. It costs around $20-$30 for the most basic scanner that only produces a trouble code.

image

1.Videos of How Do You Clean a Catalyst Dx

Url:/videos/search?q=how+do+you+clean+a+catalyst+dx&qpvt=how+do+you+clean+a+catalyst+dx&FORM=VDRE

16 hours ago  · Do you need more assistance? Visit https://www.idexx.co.uk/en-gb/veterinary/support/documents-resources/catalyst-dx-resources/

2.How to perform cleaning maintenance on Catalyst Dx

Url:https://www.youtube.com/watch?v=tgr4qv8qQOM

16 hours ago How do I clean my idexx catalyst one? Cleaning the Internal Components (Monthly) 1. Tap the Catalyst One icon on the IDEXX VetLab Station Home screen. 2. Tap Maintenance, tap Clean, and follow these on-screen instructions.

3.Catalyst DX Operators Guide - Home - IDEXX US

Url:https://www.idexx.com/files/catalyst-dx-operators-guide-en.pdf

2 hours ago Installing the Catalyst Dx Analyzer The Catalyst Dx analyzer works in conjunction with the IDEXX VetLab Station. To Install the Catalyst Dx Analyzer 1. Before you unpack the analyzer, choose an optimum location for the instrument. The analyzer should be placed on a level surface with a minimum of 2 inches (5 cm) between the back of

4.How to Clean a Catalytic Converter: 11 Steps (with Pictures)

Url:https://www.wikihow.com/Clean-a-Catalytic-Converter

12 hours ago  · To clean a catalytic converter, start by choosing a commercial cleaner made specifically for your car's engine type. Then, pour the cleaner into the gas tank and drive your car to run the cleaner through the catalytic converter.

5.Quick Reference Guide - IDEXX US

Url:https://www.idexx.com/files/catalyst-dx-quick-ref-guide-en.pdf

18 hours ago (NOT ammonia-based) to a clean cloth or paper towel and wipe the screen. Do not spray the cleaner directly onto the screen. • into place. Clean the interior of the waste drawer with a lint-free cloth dampened with 70% isopropyl alcohol. To Clean the Internal Components 1. On the Catalyst Dx* touch screen, tap Tools and then tap Clean Analyzer. 2.

6.Catalyst Dx - How to remove slides manually - YouTube

Url:https://www.youtube.com/watch?v=zAR-oZ8Saag

5 hours ago  · Do you need more assistance? Visit http://www.idexx.eu/support

A B C D E F G H I J K L M N O P Q R S T U V W X Y Z 1 2 3 4 5 6 7 8 9