How to Run Underground Cable
- Layout a pathway for the wiring run on the ground from the house to the garage, using rope or a garden hose. The...
- Use a trenching shovel to dig a narrow channel from the house to the garage, at the recommended depth for the type of...
- If necessary to cross sidewalks, dig the trench down to the required depth on both sides, then bore a...
What kind of wire in underground conduit?
Feed the Cable
- Attach a plastic underground electrical conduit outlet body to the end of the conduit.
- Push a length of UF (underground feed) electrical cable into the conduit, then feed the end of the cable through the hole in the wall.
- Pull the cable all the way to the main electrical panel. ...
Does underground wire have to be in Conduit?
What is the code for underground wiring? Low-voltage (no more than 30 volts) wiring must be buried at least 6 inches deep. Buried wiring runs that transition from underground to above ground must be protected in conduit from the required cover depth or 18 inches to its termination point above ground, or at least 8 feet above grade.
What are the requirements for underground wiring?
- The metallic covering is impervious to moisture.
- A moisture-impervious jacket is provided under the metal covering.
- The insulated conductors under the metallic covering are listed for use in wet locations. [300.5 (C) Exception 2]
Can I use flexible conduit underground?
You can use a liquidtight flexible nonmetallic conduit for areas that are wet, damp, and where fire is most likely to develop. At the same time, a liquidtight flexible nonmetallic conduit can be buried underground, as corrosion is not an issue. how far can you run liquid tight flex? 356.12 limits LFNC to six feet, with a couple of exceptions.

How do I run conduit underground?
0:064:03How to Run Underground Wiring to a Garage | Ask This Old HouseYouTubeStart of suggested clipEnd of suggested clipSo this is what we're using to bring the electricity out to the garage. It's called uf wire whichMoreSo this is what we're using to bring the electricity out to the garage. It's called uf wire which stands for underground feeder.
How far down does electrical conduit need to be buried?
In general, bury metal conduits at least 6 inches below the soil surface. You may also run them at a depth of 4 inches under a 4-inch concrete slab. Under your driveway, the conduits must be below a depth of 18 inches, and under a public road or alleyway, they must be buried below 24 inches.
How deep do you have to bury underground electrical wire?
Keep in mind that 240v power typically requires a depth of at least 18 inches. Additionally, different types of wire and conduit have specific depth requirements: GFCI-Protected Underground Feeder Cable - 12 inches. Underground Feeder Cable (UF Cable) - 24 inches.
Should underground wiring be in conduit?
It is better not to place it in conduit or bury it in the ground in any way, as it is not resistant to water, and contact with water is almost inevitable when you plant the cable in the ground.
What is code for underground conduit?
Low-voltage (no more than 30 volts) wiring must be buried at least 6 inches deep. Buried wiring runs that transition from underground to above ground must be protected in conduit from the required cover depth or 18 inches to its termination point above ground, or at least 8 feet above grade.
What wire can be used in conduit underground?
THWN-2 wire, for example, is a standard type for running through underground conduit.
What is the best underground conduit?
We typically prefer using PVC conduit when running power to a remote location underground. That gives you a lot more protection over direct burial cable in the long run.
Does underground wire need to be GFCI protected?
Also, the circuit must be limited to 15 or 20 amps and 120 volts, AND the wiring must have GFCI (ground-fault circuit interrupter) protection before the branch circuit enters the ground.
Can you use plastic conduit underground?
Good news – yes! Thanks to their flexibility and mechanical resistance flexible conduits can be installed underground to protect utilities against damage, tampering and weathering.. Flexible conduits come in extremely useful and offer a host of safety features, including corrosion, flame and water resistance.
Does underground electrical conduit need to be watertight?
Once the conduit is clean and dry and your cables and wires have been installed you must take steps to prevent water from getting into the conduit. To prevent water from condensing inside your conduit you must seal both ends of the conduit with a material that does not leak air.
What is bed material?
Bedding material. This is the material used to refill a trench from the trench bottom to your conduit (s). So, bed the bottom of your trench with select granular material free from organic matter. The material should have a sand equivalent value of not less than 20. The material should conform to the following:
Why does a conduit show corrosion?
This is why the segment of a pipe entering the ground shows much greater corrosion than other areas. Because the lower you travel underground, the soil generally becomes more tightly packed .
What to do before installing conduit?
Before you install your conduit, make sure the bottom of your trench is compact and level. This way you’ll have uniform bearing and support for each conduit section you install.
What happens when you backfill soil?
After you backfill the soil into your trench, you’ll need to compact the soil. This will make the soil denser. Thus, reducing air gaps and reducing the rate of water infiltration.
How long does an underground conduit installation last?
Because there’s much more than meets the eye with an underground conduit installation. But if you do everything properly, you’ll have an installation that’ll last you many years.
How thick should I put insulation in my yard?
It’s equal to roughly one foot of regular soil depth. So if your frost line is 5-feet below grade, install the 1-inch thick insulation at the 4-foot mark.
How far apart should I install reinforcing steel?
Additionally, install reinforcing steel as required to assure a maximum spacing of 12 inches, on center, between adjacent reinforcing steel lengths. Place number 4 bar circumferentially around the duct cross-section.
Can conduit be run under the ground?
Conduit has many different uses and applications. As a homeowner you may want to run conduit under the ground. For example, you may have a garage or a workshop that is built away from the house and situated at the other end of your lot.
Can concrete break up?
The concrete will break up and you will be able to open up the area for the conduit. You need to do this at both ends (for example: at your house foundation and also at the workshop).
Run electrical cable in PVC conduit at least 12 inches deep in the ground
The easiest way to protect outdoor electrical wiring from damage is by burying it 12-in. underground in PVC conduit. Our photo shows you the key elements of this project.
GFCI tester
Use a GFCI tester to make sure the outlet at the house is GFCI protected.
Underground Electrical Wires in PVC Conduit
Bury PVC conduit at least 12 inches down. Check all details with a local building inspector.
How deep should I dig for PVC conduit?
Dig a trench that is at least 24 inches deep, and 12 inches wide. The National Electrical Code requires that underground PVC conduit be covered by at least 18 inches of dirt when installed on private property (National Electrical Code Table 300-5).
How long to let PVC cement set?
Twist the joint back and forth several time and then let it set for 2 to 3 minutes before moving on to the next joint.
Can PVC conduit be used with steel?
Working with PVC conduit is easy and requires few special tools compared to working with steel electrical conduit. The only difficult part is digging the trench to bury it in; the trenching can be labor intensive. You may, depending on the length of the trench to be dug and on the soil conditions, want to rent a power trencher for this portion ...
Where is Jerry Walch?
Jerry Walch. Based in Colorado Springs, Colo., Jerry Walch has been writing articles for the DIY market since 1974. His work has appeared in “Family Handyman” magazine, “Popular Science,” "Popular Mechanics," “Handy” and other publications. Walch spent 40 years working in the electrical trades and holds an Associate of Applied Science in applied ...
Can you do electrical work without a permit?
Never perform any electrical work without getting the appropriate permits from the building department and always have the required inspections performed on your work. Failure to do so not only carries a steep fine if you are caught, non-inspected work can cause your homeowner's insurance to be canceled.
How far into the ground can you run cable through PCV conduit?
Running cable through a PCV conduit means that you will be digging at least 20 inches into the ground. The utility company will be able to come and tell you where there are any underground wires so you do not cut into them. Another option is to call Dig Safe for detecting any underground safety hazards.
Can you run PVC cable underground?
Running cable underground with a PVC conduit is not a difficult project, but does require work, time, and paying attention to details. If you have built a building where you want power, or are thinking of it now, here are the steps to take when running wire through an underground PVC conduit. Continue reading below Our Video of the Day.
How long does it take to get a building permit?
Depending on where you live, this can be an easy process or a lengthy one. For the most part, you will receive your building permit within a few weeks.
Do you need to run cable to an outbuilding?
Electrical cable. When you are thinking about an outdoor living area, or having power to a shed, or outbuilding, you will need to run cable for the electricity to be there. Many homeowners today are adding outbuildings for a backyard office, a workshop, a place to unwind, or another area where entertaining can be done away from the main house.
How to secure conduit to house?
Finally, slip the end of the conduit into the compression connector and tighten the compression nut with a wrench. Wrap a conduit strap around the conduit and screw it to the house to secure the conduit.
How to install EMT in basement?
Start by drilling a small hole with a long bit to make sure you're in the right spot. Then drill a one-inch hole for the LB and conduit. Screw a 1/2-in. conduit connector into the back of the LB and then attach a piece of 1/2-in. EMT that's long enough to reach an easily accessible box in the basement or crawl space.
How deep should I bury wires in RMC?
This is because the top edge of RMC has to be only six inches below the surface of the ground, while UF must be buried 12 inches deep (deeper in some situations).
How to tie a hook to a fish tape?
Tie the Wire to Fish Tape. Remove the covers from the LBs and push a fish tape through the conduit. Feed the fish tape through the conduit. Loop the wires through the fish tape and wrap them with electrical tape. Also wrap the hook on the fish tape so it can't snag. Use stranded wire, not solid wire. Step 11.
How far to add wire to shed?
Add 10 feet to the length of wire and pipe to make sure you'll have enough. It's smart to drill the hole into the house before you start digging just in case you run into an obstacle and have to choose a new location. When you're sure of the exit point, dig a trench from the house to the shed.
How many degrees can you bend a pipe?
Pro tip: Since the National Electrical Code (NEC) limits the number of bends you can make in the pipe to a total of 360 degrees, you have to plan the route carefully. The two 90-degree bends from the ground into the house and shed consume 180 degrees, leaving you 180 degrees more for any additional bends.
What gauge wire should I use for a 20 amp circuit?
Use THWN-2, 14-gauge stranded wire if you get power from a 15-amp circuit, or THWN-2, 12-gauge stranded wire for a 20-amp circuit. Leave enough extra wire on each end to reach the inside metal box plus 12 inches. Step 12.
How high above ground should a GFCI receptacle be?
They must be readily accessible from the ground and positioned no more than 6 1/2 feet above grade (ground level).
What is GFCI protection?
GFCI (ground-fault circuit-interrupter) protection is required for all outdoor receptacles. Specific exceptions may be made for snow-melting or deicing equipment, where the equipment is powered by an inaccessible outlet. The required GFCI protection can be provided by GFCI receptacles or GFCI circuit breakers.
How far away from the walls of a pool should a receptacle be?
Receptacles used to power pump systems on pools and spas must be no closer than 10 feet from the inside walls of a permanent pool, spa, or hot tub if they are not-GFCI protected, and no closer than 6 feet from the inside walls of a permanent pool or spa if they are GFCI protected.
How far above the pool deck is a GFCI?
The receptacle must be no higher than 6 1/2 feet above the pool deck. This receptacle must have GFCI protection.
How much earth cover is needed for UF cable?
UF cable can be direct-buried (without conduit) with a minimum of 24 inches of earth cover. Wiring buried inside rigid metal (RMC) or intermediate metal (IMC) conduit must have at least 6 inches of earth cover; wiring in PVC conduit must have at least 18 inches of cover.
Where should a receptacle be located?
As a general recommendation, houses also should have a receptacle at each side of a deck or balcony , accessible from the ground. Receptacles in damp locations (under protective covers, such as a porch roof) must be weather-resistant and have a weatherproof (weathertight) cover.
What is the NEC number to call before digging?
Call Before You Dig. This is not an NEC requirement, but it could save your life, not to mention prevent considerable trouble with your service providers. Call 811 , the national "Call Before You Dig" hotline, at least three days before you plan to dig anywhere on your property.