How high can you go on OxyMask?
approximately 15 litersThe OxyMask™ will reach its maximum performance at approximately 15 liters. If additional flows are required, a normal flow meter on flush will deliver up to 60 lpm. You may choose to use a high flow meter to document the exact liter flow delivered but that is often not required if you are using a pulse oximeter.
What is the purpose of an OxyMask?
OxyMask™ provides access for fluids and oral medication. Sits lightly on the face, reducing the possibility of skin breakdown under the nose, on the cheeks and on the ears. Aids compliance of prescribed oxygen therapy by reducing interruptions.
Is OxyMask same as simple mask?
OxyMask is a single mask that can be used at various flow rates and oxygen titrations. OxyMask is a viable replacement for simple masks, venturi masks, partial non-rebreather masks, and non-rebreather masks. 6 It may also replace a nasal cannula as patient acuity improves.
How much does an OxyMask cost?
More videos on YouTubeAerosol Adult Mask - OMN-1025OxyTyke Pediatric Mask - OT-1025-8Sale Price: $12.95Sale Price: $15.95OxyMask Standard Case of 25 - OM-1125-8 / OM-1425-8OxyArm - OA-PLUS-1125-8Sale Price: $359.95Sale Price: $37.953 more rows
What oxygen mask gives the most oxygen?
A non-rebreather mask is used to deliver 70 to 100 percent oxygen if you need high-concentration oxygen but don't need help breathing. Covering both the nose and mouth, a non-rebreather mask has two one-way valves.
Is OxyMask high flow or low flow?
The OxyMask (Southmedic Inc, Canada) is a new face mask for oxygen delivery that uses a small 'diffuser' to concentrate and direct oxygen toward the nose and mouth, thereby delivering high concentrations of oxygen at a relatively low flow.
Which is better nasal prongs or mask?
Most notably, face masks can provide a consistent flow of oxygen and generally have a higher recommended flow rate than standard nasal cannulas, with flow rates averaging between 6 and 10 litres per minute.
Which oxygen mask is best?
Choosing the best mask for oxygen administrationNon – Rebreather Masks. For patients who require sustained high-concentration oxygen therapy a non-rebreather mask is most suitable, providing the patient with valuable oxygen administration. ... Nebuliser Masks. ... Venturi Masks.
What is the difference between nasal cannula and oxygen mask?
A nasal cannula is a flexible tube with two prongs that go inside the patient's nostrils, while a portable oxygen mask is a plastic, rubber or silicone mask that covers the nose and mouth. There are several different kinds of oxygen masks, depending on what the patient needs.
What is the minimum flow for an OxyMask?
The Oxymask device allows for a much higher flow rate (15 L/min or more) and can achieve higher FiO2 levels at the same L/min as the Nasal Cannula. This device should be considered if a flow rate above 6L/min is needed (or 4L/min for more than 15 minutes) to return to the patient's baseline.
Do oxygen masks expire?
The majority of disposable respirators have an expiry date and once this date has passed, the respirator mask should not be used.
What percentage of oxygen does a nasal cannula provide?
The nasal cannula is a low flow system that mixes oxygen with room air. The flow rates range from 1 to 6 liters/minute, providing 24% to 44% of inspired oxygen. Rates above 4 liters/minute can dry mucous membranes and cause discomfort and bleeding, so add humidification.
Is an OxyMask a Venturi mask?
The OxyMask delivers oxygen safely and more efficiently than the Venturi mask. The tendency for carbon dioxide retention that was evident in the prototype model has been corrected by modifications to the mask design.
When was the OxyMask invented?
2005The OxyMask™ is a unique, open-style, oxygen mask that was originally developed in 2005. The original mask was modified, using computational fluid dynamics numerical simulations, with the goal of allowing it to produce a wider range of FiO2.
What percentage of oxygen does a nasal cannula provide?
The nasal cannula is a low flow system that mixes oxygen with room air. The flow rates range from 1 to 6 liters/minute, providing 24% to 44% of inspired oxygen. Rates above 4 liters/minute can dry mucous membranes and cause discomfort and bleeding, so add humidification.
How does high flow nasal cannula work?
By creating a positive pressure environment, high-flow nasal cannula presses from the interior of the nasopharynx outwards. This dilates the radius of the nasopharyngeal airways and dramatically reduces the resistance to airway flow, thus increasing ventilation and oxygenation potential.