One of the easiest ways to test this is by removing the solenoid from the reversing valve body, apply control voltage, and inserting a screwdriver. If the screwdriver is held in place, the solenoid is good. If the screwdriver falls, the solenoid needs to be replaced.
How do I know if my reverse valve solenoid is bad?
One of the easiest ways to test this is by removing the solenoid from the reversing valve body, apply control voltage, and inserting a screwdriver. If the screwdriver is held in place, the solenoid is good. If the screwdriver falls, the solenoid needs to be replaced.
How do you test a solenoid valve with a multimeter?
The quickest way to test the solenoid valve is to apply a charge directly to it. There are two wires which cross directly above the valve as it lays in the timer that you will touch with a multimeter.
How do you test a reversing valve on a car?
One way to test a reversing valve is to record the temperatures of the lines approximately 6 inches away from the body and see if there is a heat gain or loss. In the cooling mode take temperature readings at the discharge line (A) and the line going to the outdoor coil (B).
When should I replace my car’s reverse valve solenoid?
If you notice that the solenoid lost its energy or magnetism, you need to replace the solenoid. In some cases, you might be able to add charge with a 24V AC tool, but most DIYers shouldn’t try this. So, replace the solenoid. You should see an improvement almost immediately. Capillaries are all the little tubes that run the reversing valve.

How do I know if I have a bad reversing valve solenoid?
Signs Your Heat Pump's Reversing Valve Isn't Working ProperlyInability to Switch Between Modes. The ability to seamlessly toggle between heating and cooling is among the best perks of owning a heat pump. ... Diminished Heating and Cooling Performance. ... Unexpectedly High Utility Bills.
How do you check if reversing valve is working?
0:074:23How to Troubleshoot a Reversing Valve - YouTubeYouTubeStart of suggested clipEnd of suggested clipWe start by checking the temperature of the hot gas line as shown here with the temperature. Climb.MoreWe start by checking the temperature of the hot gas line as shown here with the temperature. Climb. Once this temperature has stabilized. We test the tubes.
How many ohms should a reversing valve solenoid have?
10-60 ohmsNormal solenoid resistance should be 10-60 ohms.
Is there a way to unstick a reversing valve?
The reversing valve is a pilot operated valve and requires a pressure differential to operate. If you suspect the valve is stuck, take a soft object like the plastic handle of your screwdriver and tap on either side of the valve body. This may free the valve.
What is the most common problem with reversing valves?
One of the most common problems that can develop with a reversing valve is that is can get stuck. It may become stuck in a specific mode or in between modes.
How do you test a reversing valve with a magnet?
0:101:55Testing Reversing Valves - YouTubeYouTubeStart of suggested clipEnd of suggested clipWe have a cutout of the bell to show what it looks like on the inside. I've also put a little magnetMoreWe have a cutout of the bell to show what it looks like on the inside. I've also put a little magnet here that you can watch that shift back and forth.
What should a solenoid ohm out at?
On/off solenoids have higher resistance. If you measure the resistance, it is usually greater than 10 ohms. Continuous current through these solenoids is around 0.4-0.7 Amps. They are designed to handle that amount of current indefinitely.
What Should the resistance be on a solenoid?
0:111:43How to use a Multimeter: Solenoid Testing - Purkeys - YouTubeYouTubeStart of suggested clipEnd of suggested clipShows we have a resistance of twelve point three ohms.MoreShows we have a resistance of twelve point three ohms.
Should a solenoid have continuity?
While the solenoid coil would be defective if it were electrically open (NO continuity), just having continuity doesn't necessarily mean the component is good. The solenoid's armature could be seized in place and unable to move at all or whatever that armature is connected to could be faulty as well.
What controls the reversing valve?
A reversing valve operates by a pressure difference inside a metal tube, controlled by a solenoid. The pressure change moves a slider through the tube, and this slide straddles two of three tube openings.
Is your reversing valve energized when cooling or heating?
O/B Terminals Also mentioned was the fact that reversing valves have a default position when they are not energized. Most manufacturers at this point default to heat (O terminal is energized for cooling), though there are some that still default to cooling (B terminal is energized for heating).
When should the reversing valve be energized?
When a current is applied to the reversing valve in the relaxed state, it becomes energized and switches the flow of refrigerant. Whether the energized state produces heating or cooling is something the manufacturer sets and isn't shouldn't concern the consumer.
How do you energize a reversing valve?
0:030:53Is Your Reversing Valve Energized? - YouTubeYouTubeStart of suggested clipEnd of suggested clipBoard you must have 24 volts in order to be in cooling mode if you do not the unit will run in heat.MoreBoard you must have 24 volts in order to be in cooling mode if you do not the unit will run in heat. Mode. Again when testing their reversing valve you want to test between your o.
What controls the reversing valve on a heat pump?
A reversing valve operates by a pressure difference inside a metal tube, controlled by a solenoid. The pressure change moves a slider through the tube, and this slide straddles two of three tube openings.
Can you move a reversing valve with a magnet?
0:091:51Reversing Valve Magnets - YouTubeYouTubeStart of suggested clipEnd of suggested clipSo what i have here is a couple of rare earth magnets. And so these magnets will stick to the steelMoreSo what i have here is a couple of rare earth magnets. And so these magnets will stick to the steel on the inside. So i can take it and place it one on the reversing valve here.
When should the reversing valve be energized?
When a current is applied to the reversing valve in the relaxed state, it becomes energized and switches the flow of refrigerant. Whether the energized state produces heating or cooling is something the manufacturer sets and isn't shouldn't concern the consumer.
How to test a reversing valve?
One way to test a reversing valve is to record the temperatures of the lines approximately 6 inches away from the body and see if there is a heat gain or loss. In the cooling mode take temperature readings at the discharge line ( A) and the line going to the outdoor coil ( B ). Take another set of temperature readings at the suction line ( C) and the line going to the indoor coil ( D ).
How does a reversing valve work?
The reversing valve controls the direction the refrigerant flows in a heat pump. A reversing valve is controlled by means of a pilot solenoid. The pilot solenoid creates a pressure difference in the reversing valve through pilot tubes.
What to do if a reversing valve is not shifting?
If the valve is not shifting, switch back and forth between cooling and heating. This will sometimes free the valve. Creating a greater pressure differential greater than the 30 to 70lbs. required may force the internal side to shift. Last resort is lightly tapping on the body of the reversing valve. Take care not to hit the pilot tubes. These tubes can easily be damaged or broken.
Can you condemn a reversing valve?
Do not condemn a reversing valve if the compressor is not operational or a pressure differential between the suction and head pressures is not enough. If there is the required pressure differential and the valve is not shifting, confirm there is control voltage going to the solenoid.
What is the difference between a solenoid and an electromagnet?
For you not to mistake a solenoid for an electromagnet, the significant difference between both is that solenoids are wires coiled, but not around a metal core. Meanwhile, electromagnet’s wires are coiled around a metal core, in which the amount of current applied on them determines the strength of the magnetic field.
How to test if solenoid is damaged?
For the final solenoid test that would determine if your solenoid is damaged or not, you would have to connect the red probe of your multimeter to the negative terminal of the solenoid, and the black probe of the multimeter to the positive terminal.
What happens if your solenoid is not reading voltage?
If the drop is much, the fault may be with the connection between the battery and the solenoid, but if it is not reading any voltage at all, then your solenoid is damaged and must be replaced.
How to connect a multimeter to a battery?
You have to connect the probes of the multimeter to the battery terminals, by placing the red probe from the multimeter on the positive terminal of the battery and the black probe on the negative terminal.
Why does my multimeter show a drop in voltage?
When this happens, your multimeter should display a drop in voltage until it is half a volt, if this doesn’t happen then there may be a fault with the connection between the solenoid and the battery.
What is a solenoid made of?
They are made of thin wires coiled around each other, and when current is applied to it, it produces magnetic fields for valves and switches. It is an integral part of your electrical system switches, like your vehicle engine starters. Now that you understand the solenoid and its function, you would begin to accept that the fault ...
What is the terminal on a solenoid?
The terminal on the solenoid attached to the battery is the negative terminal, and the other one that is attached to the starter is the positive terminal. Again, you should have an assistant to turn on the engine, as you check the reading on the multimeter, it should drop half a volt just as it did in the previous voltage test, ...
How much does it cost to replace a reversing valve?
We’re going to be blunt here: a good reversing valve is not going to be cheap. Reversing valves cost several hundred dollars to replace. Recent studies show that reversing valves that are stuck will cost anywhere from $200 to $650 to fix on average, with some repairs being as high as $800.
What causes a reversing valve to get stuck?
Before you assume that the valve is stuck, check to see if there are burn marks, holes, chips, or tears along the valve. A leaky reversing valve will also cause the valve to get stuck. If you notice damage or leaks around the valve, then the reversing valve may need to be replaced rather than unstuck.
How to unstick solenoid?
If you notice that the solenoid is magnetized and energized, tap either side of it with a small plastic item. This should unstick it. Give it a couple of tests to make sure it works. If it doesn’t, go to the next step.
How to check if a reversing valve is broken?
If you see broken wires, that’s your problem, not the reversing valve. Test the solenoid using a voltmeter. If you notice that it’s low on power, go to step two. If it’s fine, then this is not the problem.
What is a capillary in a heat valve?
Capillaries are all the little tubes that run the reversing valve. They need to have the fluids running smoothly through them in order to work. Check the capillary tubes in your heat valve. Are they cloggy and dirty? It could be that the capillaries are just too cloggy to work. Cleaning them out will fix the problem.
What happens if a valve is broken?
The valve is cracked or looks burned. If your valve is broken or burnt out, there’s zero chance of fixing it. The only option you really have is to replace it.
Why do you need a reversing valve?
A functioning reversing valve is a must if you want to have a home that remains comfortable. After all, it links so many functions together. If yours is stuck , this will make sure you get the most of your valve’s lifespan.