How far should a toilet be from the waste line?
If your waste line has a diameter of 3 inches, you can place the toilet within six feet of your stack. The toilet can also be as far as 10 feet from your stack, if the diameter of the waste line is 4 inches. Make homeownership easy with Kukun’s customized home maintenance schedule and service provider notifications.
How far can you vent a toilet from the stack?
There is no limit how far the toilet can be from the stack. There is a limit as how far the vent can be from the toilet. Here in NC its 10'. After you've vented the toilet you can go as far as needed. If the 2" vent you have is dry, just tee in it up 42" or so and drop down vertically in the toilet line.
Can you move a toilet without replacing the waste line?
However, you can also move the toilet to a certain extent without having to change the waste line and stack. If your waste line has a diameter of 3 inches, you can place the toilet within six feet of your stack. The toilet can also be as far as 10 feet from your stack, if the diameter of the waste line is 4 inches.
How much slop can you put in a toilet?
IIRC it is permissible (but inadvisable) to go as low as 18mm per metre, the maximum is 90mm per metre. As long as the pipe have at least 15% downhill slop from Toilet to main waste pipe it would be ok.
How far can a toilet be from the main vent stack?
6 feetAccording to the UPC, the distance between your trap and the vent should be no more than 6 feet. In other words, for the vent to work properly, it needs to feed into the drain line within 6 feet of the trapways that connect to it.
How far can toilet be from main drain?
If the toilet is less than six feet from the stack, tie the waste line from the new toilet directly into the stack. The toilet can be as far as 10 feet from the stack if the waste line is 4 inches.
How far can toilet be from Stack UK?
Six metres is the maximum run according to Building Regualtions, but as you have realised yourself, a good fall on the branch pipe is essential. 2.5º, or 44mm fall for every metre run, is the usual standard. IIRC it is permissible (but inadvisable) to go as low as 18mm per metre, the maximum is 90mm per metre.
How far can a toilet be away from a wall?
Standard Toilet Placement The minimum distance between the toilet and a finished wall on either side is 15 inches. This is measured from the toilet's centerline, not from the outside edge. The plumber determines the actual distance when he sets the toilet flange in the floor.
Can you put a toilet anywhere?
On a serious note, it is absolutely possible to install a toilet, even a bathroom as a matter of fact, anywhere in your house. In the past, many homeowners have had the idea of their dream bathroom crushed because the location was simply too far away from the main drain.
Can a shower and toilet share the same drain?
The general answer is that the showers and toilets can use the same drain, but they should not be sharing the same waste trap arm. There are other factors to consider as well, such as whether your drains lead to the main sewer line, or if there are septic tanks that are used in your city or town.
How far can you run a toilet waste pipe UK?
You can go 6m to a ventilated stack, but on ground floor vents not really necessary, as long as drain not more than 1.3m deep.
Can you extend a toilet waste pipe?
You might simply need to extend the soil pipe first with a conventional push fit coupling and length of pipe so that you can then use the fitting you have.
Can two toilets share the same drain?
Most houses have more than one toilet, and if they are on the same side of the house, their waste lines can usually tie into the same stack. If they are on opposite sides, however, each may need its own stack. Since the stacks must be vented, this would mean two vent openings on the roof.
How far out from the wall is a toilet flange?
The Distance To Set The Toilet Flange From The Back Wall. You'll want to set the center of the water closet flange 12 inches from the finished back wall.
How far does toilet need to be from shower?
The distance from the centerline of a toilet and/or bidet to any bath fixture, wall, or other obstacle should be at least 18 inches. Code Requirement: A minimum distance of 15 inches is required from the centerline of a toilet and/or bidet to any bath fixture, wall, or other obstacle.
How close can a toilet be to a wall UK?
The toilet and bidets must have a minimum space of 70cm in width and 120cm in length. If they are next to a wall, the minimum free space should be 20cm, and if there is an element on their side, they should not be placed less than 15cm away for greater usability.
How far does toilet need to be from shower?
The distance from the centerline of a toilet and/or bidet to any bath fixture, wall, or other obstacle should be at least 18 inches. Code Requirement: A minimum distance of 15 inches is required from the centerline of a toilet and/or bidet to any bath fixture, wall, or other obstacle.
How much space do you need for a toilet Australia?
You will need to establish the minimum requirements for space around your bathroom: Allow at least 600mm in front of the toilet and approximately 200mm either side of the bowl for elbowroom.
How much space do you need around a toilet?
Most codes require at least 15 inches (measured from the center of the toilet) from any side wall or obstruction and not closer than 30 inches center to center to any other sanitary fixture. (The NKBA actually recommends 32 inches.) There should be at least 24 inches of clear space in front of a toilet or bidet.
Can you put a 90 in a sewer line?
It's fine to have a larger-radius (sweep) 90-degree bend at the base of a vertical drainage stack where the wastewater starts to travel horizontally. It's also a good idea to have a sweep 90-degree fitting where a drain pipe pops out of a wall for a kitchen, vanity or laundry sink.
How far away should a toilet be from a stack?
Make sure that the toilet is positioned correctly to the stack. If the pipe is 3-inches in diameter, the toilet should be no more than 6-feet away from the stack . Similarly, if the waste line is 4-inches in diameter, the toilet should be no more than 10-feet away from the stack.
What do you need to move a toilet?
When you move a toilet, you will need to move the drainage, water supply plumbing, and fixture. The fixture is the easiest part to move, while the drainage and water supply plumbing are difficult to move. There is a series of drainage pipes under the bathroom floor.
How big is a bathroom drain pipe?
There is a series of drainage pipes under the bathroom floor. These pipes are normally 3- to 4-inches in diameter and have an intricate route that darts between other pipes and flooring joists. Drainage pipes are controlled by gravity, which means they must have a specific drop rate for the waste to drain properly.
How to stop a toilet from chipping?
Remove the Toilet. Remove the toilet. If you are reusing the toilet, be gentle with the fixture to prevent it from breaking or chipping . If you do not plan to reuse the toilet, dispose of it in a responsible manner. Then, force a rag in the drainpipe so you don’t lose tools down the pipe and block gases from rising. 1.
Do you need to measure the distance between the toilet and the stack?
You would want to measure the distance between the toilet and stack if you are moving your toilet. If your toilet is not being moved or changed in any way, you should not need to measure the distance between the toilet and stack. Aspects of Moving a Toilet.
Can you move the water supply to the toilet?
Once the toilet drain is moved, you can move the water supply. This aspect is less difficult and does not involve the distance between the toilet and main stack. Water supply pipes are much smaller and can be moved around easier. You may want to connect the relocated supply line to the existing toilet line.
How far away from a toilet can you put a toilet?
If your waste line has a diameter of 3 inches, you can place the toilet within six feet of your stack . The toilet can also be as far as 10 feet from your stack, if the diameter of the waste line is 4 inches. What about toilet flush systems?
What to consider when moving a toilet?
Because relocating a toilet is not be an easy affair, there are some key factors that you should consider before deciding to move your toilet. 1. Toilet drainage. The waste pipe of your toilet needs to be connected to the vertical sewer pipe.
Why do you need a vent pipe in a toilet?
The vent pipe plays a crucial role in maintaining sufficient air pressure in the waste pipe. You will need to align the waste pipe correctly with the vent pipe to ensure smooth functioning of the toilet.
Why is the floor of a toilet important?
The floor of a toilet plays an important role in determining the cost of your bathroom remodeling project. You may need to break into the floor to do the plumbing. If your toilet is not on the ground floor, the relocation exercise will require you to rebuild the ceiling of the underlying floor along with the toilet flooring.
How much does it cost to move a toilet?
The plumbing costs depend on a number of factors. If you are looking to change your toilet location, you can expect to spend anywhere between $2500 and $3500 in normal circumstances.
Is changing the layout of a bathroom good?
Changing the layout of your bathroom can be a huge benefit for your daily life by making your bathroom more functional and beautiful. Now that you know the important aspects of this bathroom remodel project, you can make an informed decision about relocating your toilet. Written by Billy Guteng. January 30, 2020.
Can you move a toilet?
Yes, you can actually move a toilet. Even moving a toilet by a few inches without having to make a new hole in the floor is possible. You can use an offset toilet flange to move the toilet by a couple of inches on any side. This will allow you to use the same wastewater line and in turn help to save you a lot of money.
How far above the roof should a vent be?
EXCEPTION: Where a roof is used for any purpose other than weather protection, vents shall extend at least 7 feet above the roof and shall be properly supported.
How high should vents be above the roof?
904.1 Roof extension. All open vent pipes that extend through a roof shall be terminated at least [NUMBER - typically 6 ] inches (mm) above the roof, except that where a roof is to be used for any purpose other than weather protection, the vent extensions shall be run at least 7 feet (2134 mm) above the roof.
How far is a vent from a window?
Nearest window, door, opening, air intake, or ventilation shaft: distance to plumbing vent. 10 ft (120-inches) from nearest window, measured horizontally.
stub.mandrel New Member
The new bath we have ordered is a nightmare - it's 2" wider and has a 4" bulge on the side, as a small bathroom just got tiny.
Deleted member 33931 Guest
The pipe can be as long as you need (within reason...) but will need an air vent at the loo end - essentially it's own wee vent 'stack'. What is in the room above the loo? Is it a loft? Could you run a 4" soil pipe up through the ceiling to there? In which case just shove on an air admittance valve - no need to take it through the roof.
stub.mandrel New Member
I meant the total run will be 12 feet to the branch into the stack outside (which is vented at the top), with a bend in the corner. It's upstairs. How close does an air valve have to be to the toilet.
Deleted member 33931 Guest
Hi. I probably misled you above. There are guidelines on the max length of run before a vent is needed at the 'start'. I haven't a scooby what that happens to be - plumbing peeps will be along soon to help.
stub.mandrel New Member
Hi, yes, although looking at it it might be a bit more, once new tiles are laid.
Phil the Paver Screwfix Select
Hi 21mm isn't 1 1/3", it's just a tad over 3/4" so you have plenty of fall if you have 1 1/2" Which is about 40mm.
stub.mandrel New Member
DOH! I'm, having one of THOSE days and it's not just the bloomin' toilet troubles...