how far should a cooker switch be from a cooker

by Eladio Waelchi Published 3 years ago Updated 2 years ago
image

Electrical fittings near cookers
'A minimum distance of 100mm, measured horizontally from an electrical accessory to the edge of a free standing cooker or individual hob is considered acceptable for the purposes of avoiding adverse effects from using a cooker or hob.
May 3, 2021

Full Answer

Where does a cooker switch need to be?

No, a cooker switch should be located at least 30cm (300mm) horizontally away from the hob.

How far can an isolator be from an oven?

Electric cooktops (including induction cooktops) - the isolator must be visible and readily accessible within 2 metres of the appliance and not in a position where the user would have to reach across the cooking surface. Single pole switching is acceptable.

Where do you put a cooker isolator?

The switch or control unit should be readily accessible. It should not be positioned behind or above a cooking appliance such that a person would have to reach over the appliance in order to access the switch/control unit.

Can I put cooker switch in cupboard?

Answer: It is acceptable to mount a cooker switch in a cupboard, provided that the switch is readily accessible.

Where should I put my isolator switch?

Isolator switches are installed between the meter and the mains fuse box. They're used by electricians to isolate the flow of electricity to the mains if they need to carry out work at your property.

Can a cooker switch be in another room?

The cooker switch Is acceptable PROVIDED that it is outside the specified restricted zones in the bathroom, personally I would fit it outside the room, on the landing if a cooker isolator was to be used.

Does a cooker switch have to be visible?

But there is nothing special about cooker or shower isolators - in theory, all switches need to be labelled or otherwise identified, unless there is no possibility of confusion. A neat little label will do - there is no requirement for a big one....

How far should stove be from isolator?

All too often we find the isolator for the oven directly above the stove/hob, or very close to it. The minimum distance required here is 200mm from any plug or isolator.

How far must stove isolator be from stove?

Your gas hob / cooker should be in- stalled a minimum of 200mm away from any isolator or plug point.

How close to a cooker can the switch be?

300mm horizontallyThe minimum distance a cooker switch, spur or socket can be from a hob or oven is 300mm horizontally away from the edge of the appliance.

Does a cooker switch need to be above worktop?

If you're having a new kitchen, it is considered best practice for a cooker switch to be installed within two metres of the appliance, but not within 300mm of its hot surface and not directly above. If you need to shut the appliance off for whatever reason, that local source of isolation should be readily available.

Can a cooker switch be above the cooker?

hi, it`s not a good idea to leave the c.c.u (cooker control unit)above the hob area because if there is a fire from a chip pan,frying pan etc. there is no way to isolate the circuit in an emergency.

How far should stove be from isolator?

All too often we find the isolator for the oven directly above the stove/hob, or very close to it. The minimum distance required here is 200mm from any plug or isolator.

How far must stove isolator be from stove?

Your gas hob / cooker should be in- stalled a minimum of 200mm away from any isolator or plug point.

What is the standard distance at which an isolator should be spaced from the stove or from the geyser?

A proper isolator switch shall be in place above the level of the hob and it shall have at least 200 mm clearance from the hob.

Can an oven isolator switch be in a cupboard?

There is no regulation that requires local isolators for any appliances in your kitchen. Agreed, but if there are isolators, being installed in an adjacent cupboard is perfectly acceptable.

Why is my cooker switch so close to the stove?

The main problem with cooker switches too close to the appliance comes when it has a socket outlet. What you need to avoid is the possibility of someone plugging something in, and then putting the plugged in appliance down onto a hot hob, or the hob getting turned on with an appliance sat on it (like i did whilst drunk on holiday one year and destroyed a toaster). So if the cooker switch is a bit too close and it has a socket then replace it for one without a socket. Obviously common sense should prevail if the thing is just too close altogether.

Why is an outside switch protected against water?

an outside switch is protected against the ingress of water because it is outside, if a switch is near a source of heat...

What is 300mm in cooking?

The 300mm you are talking about refers to distance away from the sink, so as long as the cooker switch isnt close to the sink aswell then I cant forsee any problems.

How far away from a hob can you install a cooker switch?

In some scenarios there may not be enough space in the kitchen to install cooker switches, sockets or spurs 300mm away from a hob or oven. In those circumstances it would be up to the installer to decide on a safe and readily accessible alternative location.

How far away should a cooker be from a sink?

Depending on which guide you read relating to cooker connection units near hobs and ovens, the distances range from 100mm to 300mm. As the recommended minimum distance for sockets near sinks is 300mm, we’d prefer to go by the 300mm rule, based on the same factors as mentioned in the sockets and sinks guidance.

Why should electrical fittings not be located above a cooker?

An electrical accessory should not be located immediately above a cooker or hob due to the possibility of people reaching over suffering burns or the flexible cable of connected equipment being damaged.’ . Source: NHBC – Electrical Fittings Near Cookers. Part P of the Building Regulations. Design and installation; P1.

How far should socket outlets be from the floor?

3. Socket-outlets should be installed at a minimum of 450mm from the floor.

Can you put a switch behind a hob?

Sockets, switched fused spurs, light switches, cooker switches and hob isolators should not be installed behind or directly above a hob or oven.

Can a kitchen fitter change the layout of an existing kitchen?

A kitchen fitter may alter the layout of an existing kitchen by relocating the hob or oven which places the hob or oven too close or directly in front of existing electrical accessories. In those circumstances you should relocate the electrical accessories to a safe location – this is best done before the new kitchen is fitted.

Can a cooker isolator get wet?

In addition to this, should a pan boil or overheat there is the potential risk of the cooker isolator getting wet. Limited space in a kitchen.

What is the standard for cooker control units?

For cooker switches, they must comply with BS EN 60669-2-4 [1], and for cooker control units the applicable standard is BS 4177 [2].

Why should a control unit be positioned?

Positioning. The switch or control unit should be positioned so that it is accessible and convenient for use. It should not be positioned behind or above a cooking appliance such that a person would have to reach over the appliance in order to access the switch/control unit.

Does BS7671 require a cooker switch?

No BS7671 does not and never has required a cooker switch. There was a requirement prior to BS7671, up until the 14th edition for a cooker switch. I believe there was a requirement in the 15th for a cooker switch used to control 2 cookers to be no more than 2m from each cooker. reply. jimsullivan_16.

Can you locate a cooker switch?

It is recommended not to locate a cooker switch or control unit in a central wall mounted control panel together with other switching devices, as this may result in the cooker switch/control unit not being under the control of persons relying on it for safety or otherwise not being suitably accessible.

Can a cooker switch be installed in a cabinet?

A cooker switch or control unit should not be installed in a cupboard or cabinet unless it will be accessible and convenient for use. In any event, wiring and other electrical equipment should not be fixed to any part of a cupboard or cabinet that is demountable in normal use.

How far away from the cooker do you need to connect an isolator?

Put the isolator where you want, but does need cooker connection unit to be within 1500 mm of where the cooker will be to connect up.

Does it matter where you put an isolator?

There are no regulations requiring an isolator for a cooker therefore it does not matter where you put it.

Is a cooker isolator the same as a motor isolator?

It is however normally expected to find a cooker isolator in the same position from cooker as a motor isolator from a motor, but there is no rule to say it must be, idea normally is should the cooker go on fire, the isolator is handy, but not where a fire would prevent its use. For a motor it states "shall be provided with an efficient means of switching off, readily accessible. easily operated and so placed as to prevent danger." and that is normally considered true for cooker, but there is not rule.

Can I wire an isolator switch to a cooker?

Yes, the isolator switch has been wired to a connection point right behind the cooker , so I don't think that'll be an issue.

Do you need an isolator for an induction grill?

However things like the cooker isolator need to have some common sense, with an eye level grill, not seen one in years, with the controls built into the grill, any fire would stop you reaching the controls, so there was a need for an isolator to one side, but with an induction hob, it will not cause ignition as not hot enough, and if the heat exceeds a set level it turns down power and if it still goes up it auto turns off, at least mine does, so there is really no need for an isolator, and when they are fitted often to keep buried cables in the safe zones they end up behind the cooker so pointless anyway as could not reach them in the case of a fire.

How far should a gas hob switch be?

Whilst no direct regulation exists for this (apart maybe from Corgi with gas hobs). Guidance is given that the switch should be 300mm to either side of the hob. Its common sense really to avoid the need to lean over a hob with a burning pan on to turn the power off etc.

Does an old kitchen have an extractor?

The old kitchen had a freestanding combined electric oven/hob cooker - there was no extractor above, but there is a heavy duty looking cooker switch and socket box above where the cooker is (is it about 70 cm up the wall from the hob/worktop level).

Can you leave a cooker switch on above a hob?

8841. You should not leave a cooker switch above a hob the heat and steam will penetrate it, water and electrical faults can and do cause fire. It is not designed to be there, If it is in use still you would not be able to turn it off in an emergency such as a pan fire or fault with the Hob when in use, you would have to stretch over the problem, ...

How far away from a cooker do you need a control unit?

These local switches serve as local isolators, functional switches and emergency switches, hence the need for the cooker unit to be not more than 2mts from the cooker or cookers. Just because the regulations do not specifically request a cooker control unit does not meat than it is not needed. Regulations are a general guide to professionals, not 'Electrics for dummies', we have to apply them as we see fit.

Which countries have a cooker switch?

The UK and Ireland are the only countries I know of where most houses have a cooker switch.

What is the isolator on a stove?

The cooker isolator is twin pole and visible by anyone working on the cooker. Where the cookers own controls are where in the event of a fire you can't operate the isolator assuming mounted to one side of cooker allows one to switch it off quickly.

How far away from a stationary appliance?

within 6 feet of the appliance. Where two stationary cooking appliances are installed in one room, one

Is a cooker switch better than a MCB?

Switch off both. The cooker switch is a double pole switch so is a better means of isolation than the MCB.

Can voltage be cut off from every circuit?

voltage may be cut off from every installation, from every circuit thereof and from all. equipment, as may be necessary to prevent or remove danger.". Don’t know about the 15th edition, and haven’t bothered looking in the 18th. Always thought having the emergency switch so close to the cooker was a bit dumb.

Do all manufacturers fit the same cooker isolation switch?

All manufacturers will more than likely be the same, do the job properly, fit a cooker isolation switch.

image

Why The Different Standards?

Image
A switch used for the control of a cooker that does not comply with Parts 2-4 of the BS EN 60669 series is not suitable for isolation purposes. It would only be suitable for emergency switching and functional purposes (Table 537.4 of BS 7671 refers). A cooker control unit complying with BS 4177incorporates a cooker control unit s…
See more on voltimum.co.uk

Function of A Cooker Control Unit

  • The cooker switch/control unit is often used to serve the following functions in respect of the cooking appliance. • A means of isolation (Regulation Group 537.2), such as to facilitate electrical connection or repair of the appliance without having to isolate at the consumer unit or distribution board • A means of switching off for mechanical maintenance (Regulation Group 537.3), such a…
See more on voltimum.co.uk

Positioning

  • The switch or control unit should be positioned so that it is accessible and convenient for use. It should not be positioned behind or above a cooking appliance such that a person would have to reach over the appliance in order to access the switch/control unit. The horizontal distance between a cooker switch/control unit and the appliance(s) it se...
See more on voltimum.co.uk

Particular Considerations For Cooker Control Units

  • The installation of a cooker control unit can lead to accidents due to trailing cables and/or portable equipment being located near to or on hot surfaces. Where a cooker control unit is provided, it should be positioned so as to minimise the risk of such accidents. If this is not practicable, it is better to install a cooker switch (without a socket-outlet), bearing in mind that a …
See more on voltimum.co.uk

1.Cooker Switch Distance from a Hob or Cooker - Pro Certs …

Url:https://www.procertssoftware.com/blog/cooker-switch-distance-from-a-hob-cooker/

24 hours ago Conclusion: How far should a socket or cooker switch be from a cooker, hob or oven. The minimum distance a cooker switch, spur or socket can be from a hob or oven is between …

2.Part P :: Cooker switch, Distance from Cooker Hob

Url:https://www.electriciansforums.net/threads/part-p-cooker-switch-distance-from-cooker-hob.31160/

8 hours ago How far does a cooker switch have to be away from a cooker? ‘A minimum distance of 100mm, measured horizontally from an electrical accessory to the edge of a free standing cooker or …

3.Socket and switch distances from a hob | Pro Certs …

Url:https://professional-electrician.com/technical/socket-and-switch-distances-from-a-hob-pro-certs-software/

18 hours ago  · As far as Im aware, there isnt a minimum distance away from the cooker, as long as it isnt directly above it, then it should be fine. The 300mm you are talking about refers to …

4.Installation of cooker switches and cooker control

Url:https://www.voltimum.co.uk/articles/installation-cooker-switches-and-cooker

12 hours ago  · Clearly an appliance delivery company does not want to run cable around the house, but I think the distance from isolator to cooker was dropped around 14th edition we are …

5.Cooker isolator switch distance | DIYnot Forums

Url:https://www.diynot.com/diy/threads/cooker-isolator-switch-distance.537426/

5 hours ago Whilst no direct regulation exists for this (apart maybe from Corgi with gas hobs). Guidance is given that the switch should be 300mm to either side of the hob. Its common sense really to …

6.Is it ok to have a cooker switch/socket box 70cm above …

Url:https://www.mybuilder.com/questions/v/2354/is-it-ok-to-have-a-cooker-switchsocket-box-70cm-above-an-electrical-hob

10 hours ago  · It should not be positioned behind or above a cooking appliance such that a person would have to reach over the appliance in order to access the switch/control unit.The …

7.Purpose of a cooker switch? | Screwfix Community Forum

Url:https://community.screwfix.com/threads/purpose-of-a-cooker-switch.217888/

13 hours ago  · If you’re having a new kitchen, it is considered best practice for a cooker switch to be installed within two metres of the appliance, but not within 300mm of its hot surface and …