- To replace or repair your thermocouple on a furnace the average cost is $100–$250
- A thermocouple is essential on older model furnaces that have pilot lights- it depends on a thermocouple to turn off its gas valve if the flame goes out
How much does it cost to replace a thermocouple?
How much does a plumber charge to replace a thermocouple? Calling a professional plumber to install a new thermocouple should only be up to $150.If you do the work yourself, you will only pay the price of the part which is about $20.
How do you replace a thermocouple on a gas heater?
- Lift the control cover and turn the gas control knob all the way to the "Off" position.
- Remove the thermocouple from its packaging and unwind it.
- Hold the probe, which is the small bulb on one end of the wire, between your fingers and reach into the burner.
How to fix a thermocouple on a water heater?
Step-by-step Guide to Cleaning a Water Heater’s Thermocouple
- Turn Off Your Water Heater’s Gas Supply. Always look after your safety when working with your gas water heater. ...
- Remove the Water Heater Burner Assembly. If your burner has an access cover, unthread the mounting screws first. ...
- Clean the Water Heater Thermocouple. ...
- Clean the Burner. ...
- Reassemble the Burner. ...
- Turn On Your Water Heater. ...
How to bypass your thermocouple on a propane heater?
What you’ll need for the test :
- Make sure to turn off your gas flow before conducting the test since you’ll have to remove the thermocouple.
- To remove the patio heater thermocouple, unscrew the connection nuts, and copper leads, followed by the bracket nuts.
- Set your meter to ohms. ...
- Turn the flame source on to conduct the actual test.
How much does it cost to replace a thermocouple on a water heater?
How much does it cost to replace a water heater valve?
Who fixes water heaters?
How long does a tankless water heater last?
How much does it cost to replace an anode rod?
How much does it cost to fix a gas water heater?
What are the upgrades needed for a water heater?
See 4 more
About this website

Can I replace a thermocouple myself?
Replacing a thermocouple is a relatively easy fix that can take less than two hours. This guide reviews how to replace a thermocouple to ensure gas appliances stay in good working order, as well as how to relight a pilot light.
Can a plumber replace a thermocouple?
The thermocouple on a water heater is what relays the gas control valve once the pilot light is lit to trigger it to turn on. The part is rather small and inexpensive, but replacing it requires the expertise of a professional plumber for safety reasons.
How do I know if my thermocouple is broken?
Hold the reset button between 30 to 60 seconds to give the thermocouple time to heat up. Release the button to see if the pilot light goes out. The pilot light should stay on after the reset. If it goes out, this is a sign that the thermocouple has failed.
How long do thermocouples last?
In effect, new thermocouples were installed into contaminated tubes, causing the degradation of the sensors and generating greater than a 100°F shift in accuracy. In this scenario, thermocouple life, which should have been close to one year, was shortened to within a week.
What causes thermocouple to fail?
Changes in temperature can cause regular expansion and contraction in metal, which will cause thermocouples to weaken over time. After enough time, metal fatigue can cause a thermocouple to break.
What causes water heater thermocouple failure?
Over time your water heater will collect dirt, dust and other kinds of debris. Build up on your thermocouple can cause a malfunction. This is and easy fix, simply let it cool down and brush off the dirt or debris. Your thermocouple might bend.
What happens when a thermocouple goes bad?
Normally when the thermocouple malfunctions or isn't working, it simply shuts off the gas to your heater. This is important, particularly if the pilot light is out, because it prevents harmful gas from leaking into your home.
How do I know if I need a new thermocouple?
A working thermocouple will give a reading of between 25 and 30 millimeters. If the reading is less than 25 millimeters, it should be replaced.
Can I bypass a thermocouple?
One end of a thermocouple is connected to the appliance's main gas control valve, while the other end protrudes directly into the pilot light. To disable thermocouples, either one end or the other needs to be removed from the source.
Does cleaning a thermocouple help?
Yes, you can clean a thermocouple, but the task must be done with a light touch. Remove the thermocouple from the process assembly, using a steel wool or emery cloth, lightly clean the tip removing any build up. Cleaning a thermocouple is not a fix for an issue, such as inaccurate readings.
Are thermocouples universal?
Universal Gas Thermocouple includes universal adapter fittings and is compatible with screw-in, push-in or clamp-type pilot burners. It is designed for gas furnaces and 30 mV systems. The element is built for reliability and long life.
How do you fix a pilot light that keeps going out?
If it's filthy shut your gas off so that the unit can cool down, then gently clean it by carefully rubbing it with fine grain sandpaper. When you're done, simply turn the gas back on and light the pilot again. If dirt or grime was the issue, your light shouldn't go out again!
How do I know if my thermocouple is bad on my water heater?
If the pilot lights but the flame goes out as soon as you release the button after holding it for 60 seconds, then the thermocouple is bad. It's possible to replace the thermocouple without removing the burner assembly, and many repair people do this.
How do I know which thermocouple to buy?
How to choose a ThermocoupleDetermine the application where you will use the thermocouple sensor. ... Determine the temperature ranges the probe will be exposed to. ... Determine how important a fast response time is. ... Consider any chemical, abrasion or vibration resistance. ... Consider any installation requirements.
How do I replace a thermocouple?
0:002:36Here putting in the new thermocouple is very easy all we do is take new thermocouple. We push itMoreHere putting in the new thermocouple is very easy all we do is take new thermocouple. We push it back into the bracket. And there's usually some type of compression fitting that holds.
Are thermocouples universal?
Universal Gas Thermocouple includes universal adapter fittings and is compatible with screw-in, push-in or clamp-type pilot burners. It is designed for gas furnaces and 30 mV systems. The element is built for reliability and long life.
How Much Does Water Heater Repair Cost? - Bob Vila
Typical Range: $221 to $964 National Average: $591 A water heater does exactly what its name suggests: It heats water. This water can be used in a home for showering, cooking, and cleaning.
Cost to Repair a Hot Water Heater - Homewyse
The basic cost to Repair a Hot Water Heater is $250 - $302 per heater in July 2022, but can vary significantly with site conditions and options. Get fair costs for your SPECIFIC project requirements. See typical tasks and time to repair a hot water heater, along with per unit costs and material requirements. See professionally prepared estimates for hot water heater repair work.
2022 Water Heater Repair Costs | Gas & Electric Water Heaters - Thumbtack
Here are water heater repair cost estimates for a few common water heater problems: Clean and repair thermocouple: $395 Replace thermostat and/or heating element: $150–$200 Leaks: Generally not affordable to repair, unless the unit is still under warranty One of the most common plumbing-related issues in a home or apartment is a hot water heater not doing its job.
Hot Water Heater Repair Costs - HomeAdvisor
Hot Water Heater Repair Cost. The national average cost to repair a water heater is $591.The typical range for repairs is between $221 and $964, though homeowners may spend as little as $100 for minor respairs and as much as $1,300 for multiple repairs.
How much does it cost to replace a thermocouple on a water heater?
The cost to replace the thermocouple on a water heater is $100 to $325. The thermocouple detects whether the pilot light is lit and signals the gas control valve to turn on the gas flow. Thermocouple replacement is the most common repair needed for gas tank water heaters.
How much does it cost to replace a water heater valve?
Replacing a water heater gas control valve costs $150 to $600. The valve controls the flow of gas to the unit, allowing the pilot light to ignite and releasing gas to the burner to heat the water in the tank. The gas control valve contains the thermostat and pilot light controls.
Who fixes water heaters?
Plumbing companies fix most water heater problems, including leaks, strange noises, rusty water, low water pressure, or no hot water. Hire a residential electrician instead if the unit trips the circuit breaker, overheats the water heater's fuse box, or has loose wiring that trips the unit's reset button.
How long does a tankless water heater last?
Tank water heaters last 8 to 15 years. Tankless water heaters last 10 to 20 years. Consider replacing a water heater over 10 years old or if the repair costs are more than 50% of the replacement cost as it's more cost-effective.
How much does it cost to replace an anode rod?
Anode rod replacement costs $150 to $350 by a professional plumber or $20 to $50 for the part alone. The anode rod is a core of aluminum, magnesium, or zinc that prevents rust and corrosion in the tank. Plumbers recommend replacing the anode rod every 3 to 5 years.
How much does it cost to fix a gas water heater?
Gas water heater repair costs $50 to $600, depending on which part malfunctions. Thermocouple replacement or gas control valve replacement are the most common repairs needed for natural gas water heaters.
What are the upgrades needed for a water heater?
Local building codes may require additional upgrades to the water heater, such as a venting system, supply pipes, drain pan, or expansion tank.
How much does it cost to replace a thermocouple on a water heater?
The cost to replace the thermocouple on a water heater is $100 to $325. The thermocouple detects whether the pilot light is lit and signals the gas control valve to turn on the gas flow. Thermocouple replacement is the most common repair needed for gas tank water heaters.
How much does it cost to replace a water heater valve?
Replacing a water heater gas control valve costs $150 to $600. The valve controls the flow of gas to the unit, allowing the pilot light to ignite and releasing gas to the burner to heat the water in the tank. The gas control valve contains the thermostat and pilot light controls.
Who fixes water heaters?
Plumbing companies fix most water heater problems, including leaks, strange noises, rusty water, low water pressure, or no hot water. Hire a residential electrician instead if the unit trips the circuit breaker, overheats the water heater's fuse box, or has loose wiring that trips the unit's reset button.
How long does a tankless water heater last?
Tank water heaters last 8 to 15 years. Tankless water heaters last 10 to 20 years. Consider replacing a water heater over 10 years old or if the repair costs are more than 50% of the replacement cost as it's more cost-effective.
How much does it cost to replace an anode rod?
Anode rod replacement costs $150 to $350 by a professional plumber or $20 to $50 for the part alone. The anode rod is a core of aluminum, magnesium, or zinc that prevents rust and corrosion in the tank. Plumbers recommend replacing the anode rod every 3 to 5 years.
How much does it cost to fix a gas water heater?
Gas water heater repair costs $50 to $600, depending on which part malfunctions. Thermocouple replacement or gas control valve replacement are the most common repairs needed for natural gas water heaters.
What are the upgrades needed for a water heater?
Local building codes may require additional upgrades to the water heater, such as a venting system, supply pipes, drain pan, or expansion tank.