Bad Car A/C Expansion Valve Symptoms
- Warm Air From Vents. The most recognizable symptom of a bad A/C expansion valve is when you turn on your air conditioner and warm air starts blowing out of ...
- Frost on the Vents. A car’s air conditioner should never be cold enough to the point where frost forms on the vents. ...
- A/C Compressor Always On. If your A/C expansion valve stays open and cannot shut properly, this is how refrigerant continuously gets pumped into the air conditioning system.
- Inconsistent Airflow. Sometimes a bad A/C expansion valve will provide an inconsistent performance in its ability to regulate the flow of refrigerant throughout the system.
- A/C System Failure. If you are experiencing any of the symptoms on this list but you continue to ignore them, it will eventually result in your entire air conditioning ...
- Air Conditioning Blows Warm Air. The expansion valve is just one of many problems that can cause your car's A/C system to blow nothing but warm air. ...
- Refrigerant Oil and/or Dye Buildup. It's possible for the expansion valve to develop leaks. ...
- Frost Accumulation.
What happens if expansion valve is bad?
What happens when an AC expansion valve goes bad?
- Make sure the AC unit is plugged in or, if it is in an automobile, turn the vehicle on.
- Use the manual to locate the thermostatic expansion valve.
- Lift the sensing bulb from the suction bulb well.
- Hold the sensing bulb in your hands for two minutes or place it in warm water.
What symptoms does a bad PCV valve cause?
PCV Valve: What it Does, and Symptoms of a Bad One
- 1. rough idle or stalling:
- 2. illuminated check engine light:
- 5. increased emissions and fuel consumption:
- 6. poor idling and acceleration:
What are the symptoms of a bad thermal expansion valve TXV?
This will cause the following symptoms: Low evaporator (suction) pressure; High evaporator and compressor superheats; Low compressor amp draw; Short-cycling on the low-pressure control; Somewhat high discharge temperature; Low condensing (head) pressure; Low condenser split; and Normal to a bit high condenser subcooling .
What are the symptoms of a bad check valve?
Here’s what to look for:
- Firm Brake Pedal When you step on the brake pedal, it should not be difficult to push the pedal down with your foot. ...
- Spongy Brake Pedal If you have air bubbles in your brake lines because of the bad check valve, you may notice your brake pedal feeling a bit spongy. ...
- Poor Brake Performance

How do you know if you got a bad expansion valve?
Symptoms of a Bad Expansion ValveAC System Blowing Warm Air. ... AC Compressor Constantly Running. ... Inconsistent Air Flow. ... AC System Performing Worse Than. ... Frost on Vehicle's AC Vents & Orifice Tube. ... Blocked Expansion Device. ... Too Much Refrigerant Flow. ... Compressor Failure.More items...
What happens if expansion valve is stuck open?
If the expansion valve is stuck open or clogged, the AC system will not cool properly. A clogged valve will lead to too little refrigerant, increasing the pressure in the system and causing the AC compressor to overheat.
How do you test an expansion valve?
You need to raise the temperature of the sensing bulb to determine if the expansion valve is activating. One easy way is to simply drop it in a cup of warm water. Otherwise, you can simply hold the bulb in your hand throughout the duration of the test.
What happens when a thermal expansion valve fails?
If the TXV fails closed it can be said to be “underfeeding,” which means not enough boiling refrigerant is fed through the evaporator coil and superheat will be too high at the evaporator outlet.
Can you unclog an expansion valve?
Opening of the valve should be relatively quick. Even holding he bulb in your hand should provide enough heat to open the valve. Next, place the TXV bulb into cold water. This should cause the expansion valve to close reducing the amount of refrigerant to pass thought the TXV into the coil.
When should you replace expansion valve?
If your expansion valve is cool and frosty, yet the air conditioning doesn't seem to be blowing cold air out, there's a good chance the valve needs to be replaced.
What causes an AC expansion valve to fail?
A TXV valve can fail if it's too open and overfeeding or too closed (underfeeding). Contaminants from a dirty evaporator coil, oil, or moisture can cause the valve to get “sticky”. In addition, a blocked return air vent can cause a TXV valve to go bad.
How to tell if your A/C expansion valve is bad?
1) Warm Air From Vents. The most recognizable symptom of a bad A/C expansion valve is when you turn on your air conditioner and warm air starts blowing out of the vents. This would obviously mean that not enough refrigerant is making its way to the core of the evaporator.
What happens if an expansion valve stops working?
When you have an expansion valve that stops working properly, the symptoms will show up quickly. These symptoms will mostly pertain to the functionality of the air conditioning system. If it is a hot summer day and you turn on your air conditioning system, you will notice something is wrong if you’re not getting the cold air that you’re expecting.
What is the valve calculating?
In other words, the valve is calculating how much refrigerant must flow through the passageway based on the demands being placed onto it. This not only includes when the driver sets a colder temperature, but also when the temperatures outside are naturally hotter.
How does an expansion valve work?
The A/C expansion valve manages this flow of refrigerant via a rod which exists inside of it. The rod can be moved either down or up, causing the passageway for the refrigerant to be either closed or opened; respectively.
What is the purpose of the expansion valve in an air conditioner?
The purpose of the valve is to manage how much refrigerant liquid can flow throughout this system. Whenever there is an abundance of refrigerant, the core of the evaporator will get too cold and eventually freeze.
Why does my evaporator get cold?
Whenever there is an abundance of refrigerant, the core of the evaporator will get too cold and eventually freeze. Just like if there was not enough refrigerant, the core would get too hot and then overheat. To prevent either scenario from happening, the A/C expansion valve controls the flow based on the temperature of the evaporator and ...
What happens if you replace an A/C expansion valve?
Even if you replace the A/C expansion valve after this happens, you will also have to fix the other components that go bad too.
What happens when an expansion valve fails?
When the expansion valve fails or has any issues, it can cause problems with the functionality and performance of the AC system. Usually a bad or failing AC expansion valve or orifice tube will produce a few symptoms that can alert the driver of a potential issue. 1. AC system performing worse than usual and blowing warm air.
What is expansion valve?
An expansion valve is an AC component that is commonly found on many road going vehicles. It is usually installed at the evaporator inlet and works together with the orifice tube to regulate the flow of refrigerant through the vehicle’s AC system. Too much refrigerant flow and the evaporator core will freeze over;
Why does my AC compressor keep running?
If the AC expansion valve fails or sticks open, it will cause the compressor to pump refrigerant through the vehicle’s AC system, even when it may be undesirable for it to do so.
What happens if you have too much refrigerant flow?
Too much refrigerant flow and the evaporator core will freeze over; too little and the evaporator core will overheat and compromise the efficiency of the AC system . The expansion valve meters refrigerant flow according to evaporator temperature and the load and cooling demand of the AC system.
Why does my AC blow cold air?
2. Frost on AC evaporator or coming from the vents. Another symptom of a potential problem with the vehicle’s AC expansion valve or orifice tube is frost coming from the vehicle’s vents.
How does an expansion valve work?
The AC expansion valve and orifice tube work together to regulate the flow of the AC system. If either component fails or has an issue, it can disturb the performance of the AC system, which can cause it to underperform. The AC system may begin to blow noticeably less cold than before and may even begin to blow warm air depending on the severity ...
Why does my AC evaporator freeze?
If the AC evaporator or orifice tube malfunctions, it can cause refrigerant to flow unmetered through the vehicle’s AC system. This can cause the evaporator to freeze over, or frost to form or come from the vehicle’s AC vents. Either symptom is a sign that the system is getting too much refrigerant, which will actually hinder its efficiency ...
How to tell if expansion valve is bad?
What are the signs of a bad expansion valve? 1 Car AC system isn't cooling enough or won't cool at all. 2 High side pressure is high. 3 Air coming from vents is frosty. 4 AC blows cold, then hot. 5 AC kicks on and then immediately kicks off. 6 Airflow drops dramatically from vents.
Why is my car AC not cooling?
Car AC system isn't cooling enough or won't cool at all. High side pressure is high. Air coming from vents is frosty. AC blows cold, then hot. AC kicks on and then immediately kicks off. Airflow drops dramatically from vents.
Can expansion valves fail?
There actually are simple Expansion valves operate under high pressure and cycle through ups and downs of temperature and pressure. The moving parts get stressed by these factors. Contaminates in the system can also cause failure.
What happens if the expansion valve is too cold?
If the expansion valve allows too much refrigerant flow, the evaporator will get so cold that it forms frost or even ice on the fins. Moisture in the cabin air can freeze into ice crystals and blow out the vents.
Why is my AC vent pressure high?
So you see very high side pressures. High pressure alone doesn’t mean the expansion valve is bad. High pressure can also be caused by a restriction in the condenser. However, in that case you should get some cooling in the AC vents.
Why does my compressor run constantly?
If you confirm that the system has the correct refrigerant charge, what’s happening is that the expansion valve is allowing too much refrigerant flow which causes the moisture in the air to freeze on the evaporator. This condition would also cause the compressor to run constantly.
Why does my AC blow cold?
AC blows cold, then hot. This can be a symptom of a low refrigerant charge. But if you’ve confirmed that the system has the proper charge and it still blows cold and then stops and blows warm air, the metering pin in the expansion valve maybe sticking open or closed.
Why won't my car AC cool?
Whether you have an H-block or remote sensing bulb expansion valve, a loss of gas in the power head can prevent the valve from opening. That results in no cooling. So the air will be noticeably less cold or blow warm.
What happens when airflow drops from vents?
Airflow drops dramatically from vents. In this case, the AC comes on strong, blowing very cold air. After a short period you notice the airflow decreasing until the point where very little air is coming from the vents and that air is warm.
Is high side pressure bad for compressor?
Unfortunately, the valve is closed. So you see very high side pressures. High pressure alone doesn’t mean the expansion valve is bad.
Why does my expansion valve go bad?
Sometimes the parts are just defective. Other times clogging in the system will damage the part. In many cases, the part simply deteriorates due to age.
What is the purpose of expansion valve?
The expansion valve regulates the amount of refrigerant funneled to the evaporator from the condenser and compressor. This part also depressurizes the refrigerant until it becomes cold enough to cool down the warm air passing through.
Why does my air conditioner keep running nonstop?
A consequence of an expansion valve that doesn't shut off like it's supposed to is that the refrigerant continues feeding into the compressor. This, in turn, causes the compressor to continue running nonstop to deal with the gas . You can tell this is happening because your air conditioner will run continuously without shutting down between cycles to let the system rest.
Can you fix a broken expansion valve?
Regardless of the cause, fixing a broken expansion valve can be challenging and should only be undertaken by a professional. However, before calling your local HVAC repair technician, it's a good idea to first determine if the valve is the source of the problems. Here are three ways you can tell.
How to diagnose a bad TXV?
To diagnose a bad TXV, look for: These conditions may appear with either a clogged TXV or a clogged liquid line, because the TXV is part of the liquid line. Most often, cleaning or replacing the inlet screen or replacing the power head to eliminate the clog resolves the issue.
What is the difference between a clogged TXV and an undercharged system?
The difference between an undercharged system and a clogged TXV is that an undercharged system exhibits low levels of condenser subcooling.
What is a TX valve?
The thermal expansion valve (abbreviated as TEV, TXV, or TX valve) controls the volume of refrigerant released into the evaporator of refrigeration systems. You’ll find them on air conditioners, heat pumps, chillers, refrigerators, and freezers.
Can TXV be misdiagnosed?
TXV problem are misdiagnosed frequently when technicians focus on pressure. Instead, looking at the broader system may help you address the root of the problem and, sometimes, make a simpler repair.
Can a compressor run constantly?
Frost may form on the evaporator. The AC compressor may run constantly. To troubleshoot the problem, start by checking the refrigerant pressures and system temperatures and comparing them to the manufacturer’s standard operating values.
Can a bad TXV cause a bad TXV?
A bad TXV isn’t the only possible cause of those symptoms, even when it contributes to them. For example, an underfed refrigeration system exhibits many of the same symptoms as a bad TXV: Frost on the valve or coil. A low pressure reading at the suction service valve. High superheat.
Why does my TXV valve have wax buildup?
Wax buildup in the valve because the wrong oil was used in the system; Sludge from the byproducts of a compressor burnout ; Partial TXV orifice freeze-up from excessive moisture in the system; Foreign material in the orifice; Oil-logged TXV from refrigerant flooding the compressor; Too much oil in the system;
How to tell if a TXV is undercharged?
However, the undercharged system will have low condenser subcooling levels. Service technicians often confuse an undercharged system with a restricted metering device. Adding refrigerant to a system with a restricted metering device will only raise the condenser subcooling amounts to a level where the head pressure may elevate. This is caused from a lack of internal volume in the condenser to hold the added refrigerant. Even the receiver may overfill if too much refrigerant is added. If the system is then pumped down for any reason, dangerous head pressures will result.
What causes low amp draw?
Low Amp Draw — High compressor superheats and low suction pressures will cause low-density vapors to enter the compressor. Also, the compressor will be partly starved from the TXV being restricted. These factors will put a very light load on the compressor and cause the amp draw to be low.
Why is the condenser low pressure?
Low Condensing (Head) Pressures — Since the evaporator and compressor are being starved of refrigerant, so will the condenser because of these components being in series with one another. There will be little heat to eject to the ambient surrounding the condenser. This allows the condenser to operate at a lower temperature and pressure.
Why is my compressor superheating?
High Superheats — High superheats also are caused by the evaporator and compressor being starved of refrigerant. With the TXV restricted, the evaporator will become inactive and run high superheat. This will cause the compressor superheat to be high. The 100 percent saturated vapor point in the evaporator will climb up the evaporator coil causing high superheats.
What are the symptoms of a liquid line restriction?
This will cause the following symptoms: Low evaporator (suction) pressure; High evaporator and compressor superheats; Low compressor amp draw; Short-cycling on the low-pressure control; Somewhat high discharge temperature;
Why does a restricted metering device cause low evaporator pressures?
Let’s look at why a restricted metering device will cause the symptoms that it does: Low Evaporator Pressures — Because the evaporator is starved of refrigerant, the compressor will be starving also and will pull itself into a low-pressure situation.