What is HL error?
What does FLC mean on a spa?
What happens if the spa probe is disconnected?
What happens if a spa relay is disabled?
What happens if you disconnect a hi-limit probe?
What is the water temperature of a spa?
Why is the heater barrel showing OTH?
See 4 more
About this website

How do I fix the HL in my hot tub?
Error code: HLClean the filters, and.Ensure the jets are open and, if applicable, appropriate valves in the equipment bay are fully open, then.Turn off the power to the hot tub for 5 minutes.
How do I fix the HL error on my Arctic Spa?
HL. The system has shut the heater down because the temperature at the heater has reached 119ºF (48ºC). Do not enter the water! Remove the spa cover and allow the water to cool down, then the shut power off and power your spa up again to reset the system.
What does HL mean on a hot tub?
HL Error Code – What does it mean? An HL error usually means there is a blockage, preventing water from circulating around the pump & heating system. The blockage can be caused by a dirty filter, a blocked impellor or limescale build up – especially if you live in an area with hard water.
How do I reset the error code on my Arctic Spa?
0:305:00Arctic Spa Error Codes for 2020 and newer Arctic Spa Custom SeriesYouTubeStart of suggested clipEnd of suggested clipIf you do see any of these error codes come up the first thing that you'll want to do is to turn theMoreIf you do see any of these error codes come up the first thing that you'll want to do is to turn the power off to the spot. And then back on again this will reset the spa.
Can a hot tub overheat?
When the pump runs, it generates heat. This heat transfers into the tub water, increasing the temperature. So, if the hot tub is set to filter too many hours per day, it can cause overheating. Adjust your filter cycle duration cycle down and set it to run early AM and late PM, when the outside temperatures are coolest.
Why is my Arctic spa not heating?
Spa does not heat: Check to see if the heat indicator is on or there are any error messages on the topside control panel. If the heat indicator is on and no error message appears contact your factory authorized dealer. Poor Jet Pressure: First check to see that the jet(s) are turned on fully.
What causes HL code on hot tub?
When “HL” error message displays, it means the system shut the heater down because temps at the heater reached 119ºF (48ºC). When “HL” error message is flashing, it means the system shut down because the water temps in the spa reached 112ºF (44ºC).
How do you fix the HFL code on a hot tub?
How to Fix Hot Tub HFL ErrorsCheck the water level in your hot tub. ... Ensure that the slide-valves, located inside the access panel, are open. ... Prime the pump to remove air out of the pipes. ... Clean the hot tub traps and skimmer baskets regularly to keep debris from entering the system.
How do I reset the high limit switch on my hot tub?
The hot tub high limit switch is sometimes triggered when you're refilling your hot tub and can be reset by pressing the large red button on your spa pack. If you need to troubleshoot other issues with your high limit switch, BE CAREFUL.
What are the codes on a hot tub?
Balboapd = Power supply, unit running on battery backup.OH = Sensors reading 112-118° F.OHH = Overheat. Spa has shut down. ... OHS = Overheat. ... Flo = Improper flow or pressure switch malfunction.Cool = Water temp 20° below set point.ICE = Potential freeze condition has been detected.Sn1 = Hi-limit sensor malfunction.More items...
How do you unlock the Arctic spa control panel?
If a button is pressed down, a “LocP” or “LocF” message will be displayed for 1 second. To unlock the keypad, simply press and hold SDS button again for 5 seconds.
How do you adjust a pressure switch on a hot tub?
Some adjustable pressure switches have an Adjustment Screw of grey plastic that accepts a small skinny flathead. Turn the screw slowly to the left, counter-clockwise, to reduce the minimum required pressure. Turn it slowly just barely beyond the point where the heater turns On.
Why are half of my hot tub jets not working?
Jets Are Not Working Properly Jets receive water outflow from the pump. When jets start failing, the most likely case is that your hot tub pump is not working correctly. You will need to diagnose hot tub problems relating to the pump. Check your pump's priming to make sure it is working properly.
Why is my hot tub control panel not working?
Control Panel is Not Working If only a part is not working, look for error messages or blinking lights. As a first step, reset your breaker. If the problem persists, turn the breaker off and disconnect the panel to examine the circuit board. Turn the power on and check if the hot tub heats up or starts to filter.
What does FLC mean on my hot tub?
Flow switch open, flow switch closedThe other one is FLC. Flow switch open, flow switch closed. The purpose of your pressure switch is to measure pressure in the line when your pump is running.
How do I adjust the temperature on my Arctic spa?
Setting Water Temperature Use the Up or Down Arrow button to regulate water temperature. The temperature setting will be displayed for 5 seconds to confirm your new selection. Water temperature can be adjusted by 1˚ increments from 59˚F to 104˚F (15˚C to 40˚C).
Arctic Spas Error Codes Table User Guide 2022
We lead where others follow. Across the globe, Arctic Spas are best known for two things – making beautiful hot tubs purpose-built for extreme weather, and for pushing the technological limits of our industry.
Arctic Spas Error Codes & Information - The Cover Guy™
Don't miss out on exclusive deals and discounts! Sign up for the Backyard Blast newsletter! First Name: Last Name: Email address: I agree to receive emails from The Cover Guy Backyard Blast newsletter containing information and offers with respect to products, including notification of sales and other exclusive offers.
Custom Series - Error Codes for Arctic Spas Hot Tub Models
We lead where others follow. Across the globe, Arctic Spas are best known for two things – making beautiful hot tubs purpose-built for extreme weather, and for pushing the technological limits of our industry.
What does HL mean on a hot tub?
HL (solid) "Overheat" - High limit. The water temperature at the heater has reached 48 degrees C. DO NOT ENTER THE WATER. Remove the spa cover and allow water to cool. Once the heater has cooled, reset by pushing any button. If the hot tub does not reset, shut off power to the spa and call your supplier for a service.
What is Eagle Leisure?
Eagle Leisure - Sales & Marketing Manager Mission = to arm you with the knowledge you need to make the best buying decisions. Fuelled by coffee (and naps). Explorer of Scotland and the world.
What does HL mean on a heater?
Welcome, how can I help you today? HL usually means High Limit sensor has failed. You need to open up the control box underneath by the pumps and find the circuit board, look on the circuit board for where the High Limit sensor plugs in then follow that wire back to the sensor and replace. It is most likely on the heater housing.
Can Artic Spa HL reset?
Artic spa HL can't reset. Empty and refill. HL high limit on
What is HL error?
If the temperature of the heater barrel is > 119oF (48oC) a High Limit (HL) Error is trigger ed. The HL error is detected in hardware and if an HL error is detected then a pin is set on the CPU to signal the CPU of the error.
What does FLC mean on a spa?
If the flow switch is reading flow while pump 1 is off, the flow switch is closed (FLC), then there could be a problem with the flow switch. In the event of an FLC error the heater is also prevented from running and “FLC” is displayed on the topside. If the heater is allowed to run without water flowing through the heater, the heater will over heat and risk damage to the spa and fire.
What happens if the spa probe is disconnected?
If the temperature probe is disconnected, the spa pack has no feedback to control the heater and temperature. As a result, the heater is prevented from running to avoid the water temperature from reaching unsafe levels.
What happens if a spa relay is disabled?
If the spa attempts to trigger a relay where a ground fault has occurred, the relay is prevented from triggering, and the topside displays “GF”. To restore function to the relay, the relay needs to be manually enabled from the ground. fault menu.
What happens if you disconnect a hi-limit probe?
If the hi-limit probe is disconnect ed from the board “Hd” will be displayed on the topside. Find the High Limit Probe board connection if not connected connect. If connected disconnect and clean terminals and then re-connect.
What is the water temperature of a spa?
Over temperature. The water temperature of the spa is > 112oF (44.5oC)
Why is the heater barrel showing OTH?
This error helps to prevent damage to the heater and fire. In the event of a rate error the message “OtH” is displayed on the topside.