A Controlled Decking Zone is an area in which certain work may take place without the use of guardrail systems, personal fall arrest systems, fall restraint systems, or safety net systems and where access to the zone is controlled. What is the maximum allowable size of a controlled decking zone?
What is a controlled deposit amount?
Controlled Deposit Amount means, for any Payment Date with respect to the Controlled Accumulation Period, an amount equal to the sum of the Controlled Accumulation Amount for such Payment Date and any existing Accumulation Shortfall.
What is a channel migration zone?
Channel migration zone (CMZ) means the area along a river within which the channel (s) can be reasonably predicted to migrate over time as a result of natural and normally occurring hydrological and related processes when considered with the characteristics of the river and its surroundings.
What is Zone 2 in Michigan?
Zone 2 means all of that part of the Lower Peninsula north of a line beginning at and drawn from a point on the Michigan-Wisconsin boundary line due west of the westerly terminus of River road in Muskegon county ; thence due east to the westerly terminus of River road; thence north and east along the center line of the River road to its intersection with highway M-120; thence northeasterly and easterly along the center line of highway M-120 to the junction of highway M-20; thence easterly along the center line of M-20 to its junction with US-10 at the Midland-Bay county line; thence easterly along the center line of the “business route” of highway US-10 to the intersection of Garfield road in Bay county; thence north along the center line of Garfield road to the intersection of the Pinconning road; thence east along the center line of Pinconning road to the intersection of the Seven Mile road; thence north along the center of the Seven Mile road to the Bay-Arenac county line; thence north along the center line of the Lincoln School road (county road 25) in Arenac county to the intersection of highway M-61; thence east along the center line of highway M-61 to the junction of highway US-23; thence northerly and easterly along the center line of highway US-23 to the center line of the Au Gres river; thence southerly along the center line of the river to its junction with Saginaw Bay of Lake Huron; thence north 78º east to the international boundary line between the United States and the Dominion of Canada.
What is a CDZ?
Controlled decking zone (CDZ ): an area in which certain work (e.g., initial installation and placement of metal decking) may take place without the use of guardrail systems, personal fall arrest systems, fall restraint systems, or safety net systems and where access to the zone is controlled.
What does "controlled entities" mean?
Controlled Entities means those entities (including special purpose entities) over which another party has the power to govern, directly or indirectly, decision making in relation to financial and operating policies, so as to require that entity to conform with such controlling party’s objectives;
What is controlled access highway?
Controlled-access highway means every street or highway in respect to which owners or occupants of abutting lands and other persons have no legal right or access to or from the same except at such points only and in such manner as may be determined by the public authority having jurisdiction over such street or highway. (ORC 4511.01 (CC))
What is controlled airspace?
controlled airspace means an airspace of defined dimensions within which air traffic control service is provided in accordance with the airspace classification;
How many square feet of decking is required for a CDZ?
Unsecured decking in a CDZ shall not exceed 3,000 square feet (914.4 m 2 ).
How wide is a CDZ?
The boundaries of a CDZ shall be designated and clearly marked. The CDZ shall not be more than 90 feet (27.4 m) wide and 90 (27.4 m) feet deep from any leading edge.
Who can access CDZ?
Access to a CDZ shall be limited to only those employees engaged in leading edge work.
What is a CDZ boundary?
Answer: Section 1926.760 (c) (3) requires that the boundaries of the CDZ be marked "by the use of control lines or the equivalent." In a CDZ, the control line restricts access by visually warning employees of an unprotected area (66 FR 5247). Control lines can be made of rope, wire, tape, or other equivalent materials, but they must clearly designate the CDZ. Examples of other acceptable methods would be a perimeter wall, guardrail system, or even a restraint system rigged so that non-leading edge workers could not access the area. In contrast, a line painted on the floor would not be considered to be equivalent to control lines since it would be less visible than a control line .
How wide is a CDZ?
The CDZ shall not be more than 90 feet (27.4 m) wide and 90 feet (27.4 m) deep from any leading edge. The CDZ shall be marked by the use of control lines or the equivalent. Examples of acceptable procedures for demarcating CDZs can be found in Appendix D to this subpart. [Emphasis added.]
What is the second purpose of fall protection?
The second purpose is to limit the size of the area where workers are unprotected by conventional fall protection. This purpose is met where conventional fall protection is in place to protect workers once the decking has been initially installed in an area "90 feet wide and 90 feet deep from any leading edge.".
How many square feet of decking is required for a CDZ?
Unsecured decking in a CDZ shall not exceed 3,000 square feet (914.4 m 2 ).
What is a CDZ?
Controlled Decking Zone (CDZ). A controlled decking zone may be established in that area of the structure over 15 and up to 30 feet above a lower level where metal decking is initially being installed and forms the leading edge of a work area. In each CDZ, the following shall apply:
How wide is a CDZ?
The boundaries of a CDZ shall be designated and clearly marked. The CDZ shall not be more than 90 feet (27.4 m) wide and 90 (27.4 m) feet deep from any leading edge. The CDZ shall be marked by the use of control lines or the equivalent.
Who can access CDZ?
Access to a CDZ shall be limited to only those employees engaged in leading edge work.
What is a controlled access zone?
A controlled access zone is a safety measure for workers at heights where guardrails or fall arrest equipment are not able to be used. OSHA requires employers to implement fall protection measures for employees working at heights of six feet or more. A controlled access zone is used to prevent non-essential workers or personnel from entering a particular area of the job site. Let’s take a look at what controlled access zones are, and how they should be implemented in compliance with OSHA regulations.
What is the difference between a warning line and a controlled access zone?
Warning line systems are generally erected to protect all workers on a job site, whereas a controlled access zone is used to control which employees have access to specific areas on a job site
How far from an unprotected edge must a controlled access zone be?
Lines marking out the controlled access zone must be set up between 10 and 15 feet from any unprotected edge. Lines must be set up to create an enclosing perimeter. Workers are not allowed inside the controlled access zone unless they are actively engaged in bricklaying or masonry activities.
What is required to be marked in a controlled access zone?
A controlled access zone must be marked clearly using tape, wire, or rope. Employers are expected to adhere to all OSHA requirements (see our checklist above).
What is a guardrail?
The guardrail is used to cordon off the area and block non-essential workers from entering. A safety monitor supervises the area and controls who is allowed through the gate. A controlled access zone is most typically used for jobs requiring workers to be on a leading edge. Examples of this might include some types of masonry and bricklaying.
How high should a safety monitor be?
The lowest point (including sagging) must be at least 39 inches above the working area and no higher than 45 inches. Control lines are required to withstand at least 200 pounds of weight. The safety monitor must be a competent individual who does not have conflicting responsibilities on the job site.
What is a warning line?
By definition, a warning line system is any type of barrier set up on a rooftop that warns workers of an unprotected edge. This also designates a working area that does not require workers to use guardrails, belts or safety net systems.
What is a control contractor?
Controlling contractor means a prime contractor, general contractor, construction manager or any other legal entity which has the overall responsibility for the construction of the project -- its planning, quality and completion.
What is a deck hole?
Decking hole means a gap or void more than 2 inches (5.1 cm) in its least dimension and less than 12 inches (30.5 cm) in its greatest dimension in a floor, roof or other walking/working surface. Pre-engineered holes in cellular decking (for wires, cables, etc.) are not included in this definition.
What is a CDZ?
Controlled Decking Zone (CDZ) means an area in which certain work (for example, initial installation and placement of metal decking) may take place without the use of guardrail systems, personal fall arrest systems, fall restraint systems, or safety net systems and where access to the zone is controlled.
How big is a deck hole?
Decking hole means a gap or void more than 2 inches (5.1 cm) in its least dimension and less than 12 inches (30.5 cm) in its greatest dimension in a floor, roof or other walking/working surface. Pre-engineered holes in cellular decking (for wires, cables, etc.) are not included in this definition.
What is a terminus point for a bridging?
Bridging terminus point means a wall, a beam, tandem joists (with all bridging installed and a horizontal truss in the plane of the top chord) or other element at an end or intermediate point (s) of a line of bridging that provides an anchor point for the steel joist bridging .