- Across-the-line or Full Voltage Non-Reversing (FVNR) is the most commonly used general purpose starter. ...
- The Reversing Starter or Full Voltage Reversing (FVR) reverses a motor by reversing any two leads to the motor. ...
- The Multispeed Starter is designed to be operated at constant frequency and voltage. ...
What do you call a motor starter across the line?
Although, from the electrical standpoint, this type of device is called FVNR (full voltage non-reversing) sometimes we call them "across-the-line". I have seen it both ways (ACL and ATL) on many different motor starter's manufacturer manuals and technical articles. What will be the right one? Please let us know here why this post is inappropriate.
What is the full form of ATL starter?
ATL = Across The Line (acronym used by some motor starter's manufacturers and end-user sector, mostly in USA). ATL starter is defined as follow; a category of starters in which the motor is directly connected to the supply lines, allowing full voltage when the motor starts; therefore across the line.
Can you use a solid state starter on a direct line?
Solid-state direct on line starters also exist. A direct on line starter can be used if the high inrush current of the motor does not cause excessive voltage drop in the supply circuit. The maximum size of a motor allowed on a direct on line starter may be limited by the supply utility for this reason.
What is the function of autotransformer in a motor starter?
Such type of motor starters uses an autotransformer as a step-down transformer to reduce the voltage applied to the stator during the starting stage. It can be connected to both star & delta connected motors.

What are the two types of starters?
However, the two most basic types of these electrical devices are:Manual Starters.Magnetic Motor Starters.Direct-On-Line Starter.Rotor Resistance Starter.Stator Resistance Starter.Auto Transformer Starter.Star Delta Starter.NEMA Rating.More items...
What are the types of starter?
Different types of starter motors are as the below:Rotor Resistance or Slip Ring Motor Starter.Direct Online Starter (DOL)Stator Resistance starter.Soft Starter.Variable frequency drive (VFD)Autotransformer Starter.Star Delta Starter.
What is across the line control?
Across-the-Line combination controllers are complete motor control packages used in applications requiring a disconnecting means, starting circuitry, and motor overload protection.
How does a line starter work?
Principle of Direct On Line Starter (DOL) The motor will develop Locked Rotor Torque and begin to accelerate towards full speed. As the motor accelerates, the current will begin to drop, but will not drop significantly until the motor is at a high speed, typically about 85% of synchronous speed.
What are 3 types of motor controls?
There are four basic motor controller and drive types: AC, DC, servo, and stepper, each having an input power type modified to the desired output function to match with an application.
What is a 3 phase motor starter?
This type of three-pole motor-starter is usually described as a three-phase across-the-line or full-voltage motor-starter because full line voltage is applied to the respective motor leads when the motor-starter solenoid coil is energized.
What does DOL mean in electrical?
Direct on lineDirect on line (DOL) motor starting is when a motor is started at full load, with full line voltage applied to motor terminals. As this causes the motor to draw a large amount of current, it is only suitable for motor powers up to 4Kw, with a maximum motor size of 10Kw connected this way.
How is across the line starting accomplished?
The simplest method of starting a motor is the across the line starting and is accomplished by connecting the motor to the power line directly. The across the line starting method is suitable for both AC and DC motors.
What is the difference between a soft starter and VFD?
The main difference between the two is that a VFD can vary the speed of a motor while a soft starter only controls the starting and stopping of that motor. When faced with an application, price and size are in the favor of a soft starter. A VFD is the better choice if speed control is required.
What is the difference between a motor starter and a contactor?
The contactor applies voltage to a contactor coil to close the contacts and to supply and interrupt power to the circuit. A motor starter is simply a contactor PLUS an overload relay and is rated by motor HP or amperage. If there is no overload relay it is not a starter any longer. It's back to being just a contactor.
Does a 2 hp motor need a starter?
Generally speaking, low-power motors do not require starters, although what's considered low power may be debatable. For instance, small dc motors that run on low voltages (24 V or less) don't require starters. Sometimes it's said that low-horsepower motors, below 5 hp, don't require starters either.
Why across the line starting is undesirable for large electric motors?
As the rotor speeds up the current will drop until it reaches run speed at load. Motors that start across the line accelerate to run speed rapidly. Because of the high currents that occur during across the line starts, extreme caution should be observed.
What is a motor starter?
A motor starter is an electrical device that is used to start & stop a motor safely. Similar to a relay, the motor starter switches the power ON/OFF & unlike a relay, it also provides a low voltage & overcurrent protection.
What is a push button starter?
This type of starter operates manually and does not require any experience. A push-button is used to turn OFF & ON the motor connected with it. The mechanism behind the button includes a mechanical switch that breaks or makes the circuit to stop or start the motor.
What is a reduced voltage starter?
The most common type of starting technique is to reduce the voltage at the starting of the motor to reduce the inrush current that could damage the windings of the motor & also cause a huge dip in voltage. These starters are used for high rated motors.
Why is the voltage across a motor minimum?
Therefore the voltage across the motor is minimum (in safe level) due to the voltage drop across the resistor. The low stator voltage limits the starting inrush current that can damage the motor windings.
What is a stator resistance starter?
Stator resistance starter uses the RVS (reduced voltage starter) technique to start a motor. External resistance is added in series with each phase of a 3 phase induction motor’s stator. The resistor’s job is to reduce the line voltage (subsequently reducing the initial current) applied to the stator.
What is the function of the start and stop buttons on a motor?
The start and stop push buttons connected to the motor and starter can be used for ON and OFF operation of motors.
How does a slip ring motor work?
It works only on a slip ring induction motor that is why it is also known as a slip ring motor starter. External resistances are connected with the rotor in star combination through the slip ring. These resistors limit the rotor current & increase the torque. This, in turn, reduces the starting stator current.
Why use a direct on line starter?
A direct on line starter can be used if the high inrush current of the motor does not cause excessive voltage drop in the supply circuit. The maximum size of a motor allowed on a direct on line starter may be limited by the supply utility for this reason.
What is a motor starter?
Motor starters. See also: Motor soft starter. A small motor can be started by simply connecting it to power. A larger motor requires a specialized switching unit called a motor starter or motor contactor.
What is auxiliary contact in starter?
Starters using magnetic contactors usually derive the power supply for the contactor coil from the same source as the motor supply. An auxiliary contact from the contactor is used to maintain the contactor coil energized after the start command for the motor has been released.
How does a soft starter work?
Reduced-voltage or soft starters connect the motor to the power supply through a voltage reduction device and increases the applied voltage gradually or in steps. Two or more contactors may be used to provide reduced voltage starting of a motor. By using an autotransformer or a series inductance, a lower voltage is present at the motor terminals, reducing starting torque and inrush current. Once the motor has come up to some fraction of its full-load speed, the starter switches to full voltage at the motor terminals. Since the autotransformer or series reactor only carries the heavy motor starting current for a few seconds, the devices can be much smaller compared to continuously rated equipment. The transition between reduced and full voltage may be based on elapsed time, or triggered when a current sensor shows the motor current has begun to reduce. An autotransformer starter was patented in 1908.
What type of starter is used for a large motor?
Very large motors running on medium voltage power supplies (thousands of volts) may use power circuit breakers as switching elements. A direct on line (DOL) or across the line starter applies the full line voltage to the motor terminals. This is the simplest type of motor starter.
What does the green button on a motor do?
It insists that the green button is pressed to start the motor. The green button switches on a solenoid which closes a contactor (i.e. switch) to primarily power the motor. It also powers the solenoid to keep the power turned on when the green button is released.
How long does a series reactor carry a heavy motor?
Since the autotransformer or series reactor only carries the heavy motor starting current for a few seconds, the devices can be much smaller compared to continuously rated equipment.