What is iqi (image quality indicator)?
The Image Quality Indicator (IQI) consists of wires of varying thickness (where wire material is the same as the test piece material), which are welded into a plastic film. The thinner the depicted wire on the radiograph, the higher the image quality level. In the USA two main types of IQI are ASTM and MIL-STD types IQI. What is a Penetrameters?
What is the iqi Academy?
The IQI Academy delivers a proven, principle-centered foundation of management and quality education. Deming’s 14 points and System of Profound Knowledge are being applied successfully by leaders in many different organizations in industry, education and government. ON-THE-COURT
What is the iqi used in RT?
So, the IQI is used in RT to establish the RT film image quality. It is positioned on the object that has to be radiographed to evaluate the radiograph sensitivity. The Image Quality Indicator (IQI) consists of wires of varying thickness (where wire material is the same as the test piece material), which are welded into a plastic film.
What are iqis and how are they used?
IQIs include mortality indicators for conditions or procedures for which mortality can vary by hospital; utilization indicators for procedures for which utilization varies across hospitals or geographic areas; and volume indicators for procedures for which outcomes may be related to the volume of those procedures performed.

What is IQI sensitivity?
The sensitivity of an industrial radiograph is determined by the use of one or more image quality indicators (IQIs). The IQI will either be a hole type IQI containing three different sized holes or a wire type IQI containing six different sized wires.
What is the purpose of Penetrameter or IQI?
The image quality indicators (IQIs), which are also referred to as penetrameters, are test pieces used to control a radiograph's quality. IQI indicates the contrast sensitivity and definition of the radiograph and serves the purpose of product testing.
How many types of IQI are there?
There are four broad patterns of IQI in use today - the wire type, the step/hole type, the hole-in-plaque type and the duplex wire type. The first three of these are widely specified in many Standards for film radiography.
How do I select IQI?
Placement of IQIs IQIs should be placed on the source side of the part over a section with a material thickness equivalent to the region of interest. If this is not possible, the IQI may be placed on a block of similar material and thickness to the region of interest.
How do I select IQI in radiography?
The IQI is placed on a radiography film while doing the radiography. The image will be caught in the film. If the wire having 0.16mm diameter is visible in the radiography film, then we can say that the film is having a sensitivity of this 2%. The IQI that is commonly used is of ASTM and DIN standards.
How is IQI sensitivity calculated?
As with the wire IQI, the material and dimensions of the step wedge are selected to match the application. The diameter of the smallest hole visible on the radiograph determines the sensitivity, this being calculated as hole diameter divided by component thickness expressed as a percentage.
Which isotope is used in radiography?
Two of the more common industrial gamma-ray sources for industrial radiography are iridium-192 and cobalt-60. These isotopes emit radiation in a few discreet wavelengths. Cobalt-60 will emit a 1.33 and a 1.17 MeV gamma ray, and iridium-192 will emit 0.31, 0.47, and 0.60 MeV gamma rays.
How many wires are in each set of a wire type IQI?
Each indicator consists of a series of seven parallel wires of different thickness mounted and encapsulated between two thin sheets of transparent, flexible PVC.
What is OFD in radiography?
OFD – Object-to-Film Distance – is the distance between the radiation side of the test object and the film surface, measured along the central axis of the radiation beam.
What is double wall double image?
Double-wall double-image (DWDI) Image of both walls is projected onto the same film area. The determination of defect location and depth is difficult in this DWSI viewing.
How do we measure sensitivity of the RT film?
The sensitivity attained on different parts of a specimen, even on the same radiograph, may not be constant due to variations of thickness etc., and IQIs are used to assess the sensitivity in different parts of the image. of any such effects needs to be judged, and an IQI is the method usually used.
Which welding inspection method requires the use of an image quality indicator?
Visual inspection is a non-destructive testing (NDT) weld quality testing process where a weld is examined with the eye to determine surface discontinuities.
When referring to a 2T or 4T hole in the ASTM Penetrameter T refers to?
When referring to a "2T" or "4T" hole in the ASTM penetrameter, the T refers to: the penetrameter thickness. A graph which expresses the relationship between the logarithm of the exposure applied to a photographic material and the resulting photographic density is called: the characteristic curve.
What is geometric unsharpness in radiography?
Geometric unsharpness (Ug) is the lack of sharpness in an image that results from variation in the geometry of an X-ray system set-up.
Which isotope is used in radiography?
Two of the more common industrial gamma-ray sources for industrial radiography are iridium-192 and cobalt-60. These isotopes emit radiation in a few discreet wavelengths. Cobalt-60 will emit a 1.33 and a 1.17 MeV gamma ray, and iridium-192 will emit 0.31, 0.47, and 0.60 MeV gamma rays.
What causes geometric unsharpness?
Geometric unsharpness is caused by aspects of the geometry of the X-ray beam. Two principal factors play simultaneously: the apparent focal spot size and the ratio between object-film distance (OFD) and focus-film distance (FFD).
Why do we use IQIs on wires?
Wire IQIs are placed on the weld so that the length of the wires is perpendicular to the length of the weld. The identification number (s) and, when used, the lead letter ‘F’ must not be in the area of interest, except where the geometric configuration of the component makes it impractical.
What is the T-277?
T-277: use of IQIs to monitor radiographic examination. T-277.1: placement of IQIs. For the best results, IQIs are placed on the source side (i.e. nearest the radiographic source) of the part being examined. If inaccessibility prevents hand-placing the IQI on the source side, it can be placed on the film side in contact with the part being examined.
We look after our customers
It is our belief that business, values and results are inseparable. Values inspire trust, trust builds relationships and relationships drive growth.
Our People
At IQI, our agents are constantly groomed and monitored to ensure they keep up with the industry’s demands. “We Enjoy Life” while working hard to achieve our dreams, and we seek to reward our warriors as they strive harder to accomplish new milestones and improve results.
Our Journey
In a short span of time, IQI has nurtured regional offices in 21 countries, with a strong global sales team of about 21,000 dedicated property and investment experts.
Who approves iQIES access requests?
A State Agency Security Official will approve/reject iQIES access requests for employees of their State Agency. Current OASIS Automation Coordinators and Automated Survey Processing Environment (ASPEN) Technical Coordinators will be logical candidates for this role because of their technical understanding and experience in working with providers and state agency personnel. iQIES will require that this user be able to access ASPEN to verify Federal Surveyor IDs for users with existing Federal Surveyor IDs or if needed, access ASPEN to create Federal Surveyor IDs for new Federal Surveyors requesting access to iQIES. The State Agency Security Official will receive email notifications when they have pending iQIES user role requests, and when applicable, notifications to verify users’ Federal Surveyor IDs, which will need to be entered/verified in iQIES>User Management.
What is iQIES in 2021?
Beginning in May 2021, State Survey Agencies began a phased transition to the Internet Quality Improvement and Evaluation System (iQIES), which is an internet-based system for survey and certification functions. iQIES will replace and consolidate functionality from the QIES, CASPER and ASPEN legacy systems.
Where is the IQIES pilot?
CMS is planning to conduct an initial pilot in the CMS Atlanta Location including the state agencies in this region (Alabama, Florida, Georgia, Kentucky, Mississippi, North Carolina, South Carolina, and Tennessee).The pilot release will be conducted to gather data and user feedback so that we can ensure the best possible experience for iQIES users nationwide. CMS anticipates releasing Survey & Certification capabilities for HHAs nationally by the fall of 2021.
What is the value of the IQI Academy?
The Value of the IQI Academy lies not in the tools that we present and exercises we conduct (although the tools and exercises are very helpful), but in the new and empowering perspectives that are provided by the System of Profound Knowledge. New perspectives allow you to transform your understanding of the world and of what is possible. As a result, you come to better understand your customers, your organization, and what is needed to produce improvement.
What is PDSA in IQI?
An “on-the-court” vs. “in-the-stands” approach to learning is the heart of the IQI Academy. The use of weekly PDSA (Plan/Do/Study/Act) improvement cycles is one of the foundational approaches that gets participants “on-the-court” and learning from Day 1 of the IQI Academy.