What is pipe bonding? Bonding Metal Piping Systems. So, in simplest form, grounding or grounded means connecting to the earth, and bonding means connecting metallic parts together to establish continuity and conductivity between them. Click to see full answer.
What are The CSST gas line requirements?
How else to Identify FAC:
- FAC does not require bonding. This is because they are connected to a bonded (if properly installed) gas-distribution system.
- It is between 1–6 feet long.
- FAC are commonly found between the home’s gas-supply lines and the gas equipment OR appliance.
- FAC corrugation is highly visible. ...
What is the difference between grounding and bonding?
What is the difference between Bonding, Grounding and Earthing?
- Bonding, Grounding and Earthing. One of the most misunderstood and confused concept is difference between Bonding, Grounding and Earthing.
- Introduction ground or earth. ...
- Bonding. ...
- Earthing. ...
- Grounding. ...
- Micro Difference between earthing and Grounding. ...
- Illegal Practice of interchange Purpose of Grounding and earthing wire. ...
How to bond gas meter?
obtain the bonding required by national codes. For example, your electrician may choose to connect the bonding conductors from the gas house piping to the customer's side of BGE's metering equipment at a point past the meter outlet valve (the customer's main gas valve). If your electrician has questions about why the
What is grounding and bonding for telecommunication systems?
Guidelines for Grounding and Bonding Telecom Systems-EC&M. Because bonding and grounding systems within a building are intended to have one electrical potential, coordination between electrical and telecommunications bonding and grounding systems is essential during design and installation. One way to coordinate these efforts is to follow ...

Why do you bond pipes?
The current will always take the easiest path to ground; the idea of Main Bonding (and Supplementary Bonding) is to create an alternative path for the current to flow that is an easier path than along one of your heating pipes, along your arm, through your body, down your legs to the wet kitchen floor and to ground.
Do water pipes need to be bonded?
Since Section 250.104(A) requires all water-piping systems to be bonded back to the service, and hot or cold water lines are not specifically mentioned, both hot and cold water lines must be bonded and connected back to the building service.
How do you bond a water pipe?
0:466:08Need not be connected to the protective equipotential bonding. So the simple answer is no this pipeMoreNeed not be connected to the protective equipotential bonding. So the simple answer is no this pipe does not require bonding.
When should I bond my water pipe?
You must bond metal piping systems (such as gas or air) to an effective ground-fault current path, if they're likely to become energized [250.104(B)]. According to the NFPA's National Fuel Gas Code, the equipment-grounding (bonding) conductor for the circuit that may energize the piping can serve as the bonding means.
What is the difference between grounding and bonding?
Bonding is the connection of non-current-carrying conductive elements like enclosures and structures. Grounding is the attachment of bonded systems to the earth. Both are necessary to safeguard people and property from electric hazards.
Why are pipes earthed?
If the pipe is earthed, the earth leakage will trip as soon as it happens. Without earth, the whole length of the pipe would be at 240V; so not great for turning your taps on. Many other examples of where it could be useful, but nowadays there is so much plastic used in plumbing this is not a required practice.
Do plastic pipes need bonding?
If the pipes are made of plastic, they do not need to be main bonded. If the incoming pipes are made of plastic, but the pipes within the electrical installation are made of metal, the main bonding must be carried out.
What is main bonding?
Main bonding - Green and yellow conductors that connect metal pipes (gas, water or oil) from inside a building to the main earthing terminal of the electrical installation.
Why are water pipes earth bonded?
In essence, the intention behind bonding extraneous-conductive-parts is to limit the potential difference across the body when a fault occurs in part of the electrical system.
What needs bonding in a house?
Why do I need protective bonding? If you have metal water and gas pipes coming into your home – these are typically found in older homes. Protective bonding is an essential requirement of every electrical installation, however it is often overlooked by an unqualified person attempting electrical work themselves.
Is earth bonding still required?
As of 2008, earth bonding is a legal requirement for any electrical installations in rooms that contain a shower or bath. The term 'earth bonding' refers to the use of a thick green and yellow copper cable to connect your gas meter or consumer unit to incoming supplies such as your gas pipe.
How do you bond copper pipe?
1:152:51And that's plenty get the fitting that you've coated. And push in to the pipe. And twist around aMoreAnd that's plenty get the fitting that you've coated. And push in to the pipe. And twist around a couple of times and you'll find that that's bonded pretty well grab a cloth.
Do copper pipes need to be grounded?
Answer: Most electrical codes require a home's electrical system to be grounded through the copper or galvanized-iron water supply pipes that lead from the water main to your faucets. This is done by clamping the ground wire from the panel to a pipe.
How do you bond hot and cold water pipes?
0:185:35Line the cold water and the hot water okay and um mine doesn't have this but sometimes there's aMoreLine the cold water and the hot water okay and um mine doesn't have this but sometimes there's a dielectric. Between these two and you have to do it above.
Does PEX need to be grounded?
Proper home grounding is required with PEX plumbing. To ensure occupant safety, prevent fire, and protect appliances and electronics, use an 8-foot grounding rod. Refer to local code and consult a licensed electrician or plumber where needed.
What is the purpose of a water piping bond?
The main purpose of this bond is to ensure that the metal water pipe is at the same zero voltage to ground as the service grounded conductor. A secondary purpose is to ensure that there is a path back to the service for electrical current flow if the metal water pipe becomes energized. At what point is the water piping system not considered ...
How to splice plastic tubing?
Joints and splices in the plastic tubing system are accomplished by using solvent cement with insert fittings that fit into the tubing or are joined by heat fusion. The transition from nonmetallic water pipe inside the walls to a plumbing fixture, such as a sink, toilet or a hose bibb, is accomplished by using a copper 90-degree elbow and a short piece of copper tubing. The copper elbow is attached to the nonmetallic water pipe by solvent cement, heat fusion or by metal corrosion-resistant compression fittings.
How many feet of water pipe is required for a nonmetallic water system?
It’s where the water pipe does not have a direct metal-to-earth connection for 10 feet or more. A predominantly nonmetallic piping system is unlikely to have 10 feet of metal pipe in direct contact with the earth. Section 250.104 (A) requires a metal water piping system installed in or attached to a building to be bonded back to ...
What is an assessment of the amount of metal in a water system?
An assessment must be made regarding the amount of metal in the system and whether this metal pipe and any metal support for the metal piping may become energized . It is also important to determine if a difference of potential could exist between the metal piping in the water system and an electrical circuit located in proximity to the water pipe.
Why can't you rely on plastic piping?
Steve: First off you can't rely on plastic piping because you wouldn't be able to connect the ground to the water through the pipe without puncturing it. Now if you made a device that punctures without a leak, still nope. Copper is millions of times more conductive than water.
What is a copper stub?
The copper stub is the connection point for the water angle-stop or shut-off valve at the fixture. Often the flexible connection from the angle stop to the plumbing fixture is nonmetallic.
What is the NEC code for underground water pipes?
Section 250.50 of the National Electrical Code (NEC) requires that a metal underground water pipe in direct contact with the earth for at least 10 feet or more be used as one of the grounding electrodes for the electrical service to the building. This metal water pipe electrode, along with any other electrodes at the building or structure, ...
What is a gas piping bonded to?
6.13.1 Each aboveground portion of a gas piping system that is likely to become energized shall be electrically continuous and bonded to an effective ground-fault current path. Gas piping shall be considered to be bonded when it is connected to gas utilization equipment that is connected to the equipment grounding conductor of the circuit supplying that equipment.
What are the requirements for bonding metal water piping?
The requirements for bonding metal water piping systems, by definition, are to establish required continuity and conductivity with a capacity to handle any fault current likely to be imposed . If metal water piping systems are not bonded to the electrical system in a way that meets the requirements of the Code, they can present a fire or shock hazard within the building or structure because they could become energized. This portion of the article covers metal water piping systems, but similar rules apply to other metal piping systems as well, such as metal gas piping systems. We’ll discuss those requirements later in the article.
What is the minimum sizing requirement for bonding jumpers?
Bonding jumper (s) are required to be sized using 250.122, based on the rating of the overcurrent device protecting the branch circuit that is likely to energize the piping system. For example, if a gas furnace is supplied by a 30-ampere branch circuit that includes a 10 AWG copper equipment grounding conductor, the 10 AWG
How many AWG jumpers are needed for a copper water piping system?
be permitted to be sized based on the rating of the overcurrent device protecting the feeder (100 amperes) which in this example would be a minimum of an 8 AWG copper bonding jumper. Remember, the metal water piping system in each of the occupancies must be metallically isolated from the other occupancies before this alternative water piping system bonding method may be used.
How far from the grounding electrode must a water piping be made?
A major requirement to observe is that the connection to a metal water piping system that is a grounding electrode, in accordance with 250.52 (A) (1), must be made not more than 1.52 (5 ft) from its point of entrance to the building or structure. This provides a reasonable dimension so that if metal water piping is replaced with nonmetallic piping, interrupting the electrical continuity, the change is more obvious. The primary reason for this is to keep the length where the water piping serves as the connection to the grounding electrode to a minimum within the building or structure. If the metal water piping is not a grounding electrode, the connection of the bonding jumper in accordance with 250.104 (A) does not have be located within the first 1.52 (5 ft) of the water piping system entry to the building or structure.
Why are short sections of nonmetallic piping not required to be bonded?
Short sections of metallic piping in a nonmetallic piping system typically are not required to be bonded because they do not constitute a full metal piping system. Because many plumbing fixtures use nonmetallic components, bonding both the hot and cold piping systems helps ensure that both are electrically continuous.
Why do you need a bonding jumper?
The bonding jumper for a metal water piping system is required to be installed to establish electrical continuity and conductivity (an effective fault current path) to one of the following locations:
What is a grounding conductor?
The grounding conductor is the one used to connect noncurrent-carrying metal parts of equipment, raceways, and other enclosures to the system grounded conductor, the grounding electrode, or both, at the service equipment or at the source of a separately derived system.
Is gas piping included in section 250-104?
My opinion is that metal gas piping is not included in Section 250-104 (c) for other reasons. It may be run on the outside as well as the inside of the building, and its exposure to lightning would require it to be sized according to Section 250-66. It may be difficult to pinpoint which circuit ...
What is the bonding requirement for gas piping?
Modern bonding for gas piping. Today’s bonding requirement for gas piping comes from section 250.104 (B) of the 2017 National Electric Code (NEC), which says the following: If installed in or attached to a building or structure, a metal piping system (s), including gas piping, that is likely to become energized shall be bonded to any ...
What happens when metal is bonded?
Oftentimes, there will be so much current that it trips a circuit breaker.
What is Pipe Bending?
Pipe bending is one of the post-fabrication processes done on fabricated pipes to transform it into a functional product. Bending can be done manually with the help of a bending clamp and force or by using machines that are calibrated to bend the pipe to a company’s preferred shape.
What is the cheapest way to bend a pipe?
Ram bending is the cheapest and one of the traditional ways to bend pipes that is still in use today. When you use this method, the pipe will be held in two key points while it is bent with the help of a bending ram. The ram will bend the tubes with the help of fixed rollers and a ramming cylinder.
What is ring roll bending?
As its name implies, ring roll bending is great for shaping circular pipes with large and centerline radiuses. Three separate ring rolls are used for this method. When the process begins, the top roller will input the right amount of downward pressure needed by the bottom rollers to bend the tube. The rollers can be adjusted manually or mechanically if you will be using a machine to do this process.
What is Electrical Bonding?
Electrical bonding is the practice of connecting metallic objects that may be exposed to electrical faults or induced voltages to the grounding conductor. This ensures that in the event of a fault the current will have a low resistance path to take to trip the overcurrent devices as quickly as possible, as well as providing a path for static electricity and induced voltages to drain out. Bonding conductors must also be sized so that they can safely carry the largest possible load that might occur in a fault condition. Consult your local codes and regulations for how to size these conductors properly.
Why is electrical bonding important?
Another important use for electrical bonding is to reduce touch potential, especially in long runs of conductive cable tray. When voltage is applied to a conductor, be it a wire or anything else metallic, there will be some voltage drop across the length of the conductor based on its size, material, and length.
When preparing bonding jumpers for expansion joints, what to do?
When preparing bonding jumpers for expansion joints, leave an extra bend in the wire or use a flexible bonding jumper to keep a good connection even when the tray expands and contracts. Cable tray can expand several inches in either direction during extreme heat or cold conditions.
What is grounding in electrical?
Simply put, grounding is the way that parts of an electrical circuit or system are connected to the earth. Grounding includes any grounding conductors, grounding electrodes, and the connections used to securely fasten these parts together.
Why do pools have to be bonded to earth?
Metal parts of pools, hot tubs, and fountains must be bonded to earth to reduce the risk of shocking anyone who might come in contact with these surfaces, especially when the watery environment increases the chances of providing a path to ground through a person’s body.
How to make a good ground connection?
There are a variety of ways to create a good ground connection, and they vary by country, region, and application . The most common types can include ground rods, plates, electrodes, or grids of buried ground wire. Even some non-electrical parts, like buried metal water or gas pipes, can be used as an in-situ grounding electrode in certain situations. To join the grounding conductor to the grounding electrode, special fittings must be used. They may be hydraulic compression fittings, mechanical lugs, or soldered connections. Codes will also state what size and type of conductor to use, and what combination of grounding devices may be used. Large facilities may require a network of grounding devices, wire, grids, and conductors to satisfy code requirements. Always check with your local codes and regulations to ensure that you are installing a safe and code-compliant system.
Why do we bond piping?
We bond our powder handling system piping due to some interpretation of the British Standards. In it is stated the same 10x6 ohms is adequate, but then it goes on to state that, in general, piping is usually somewhere tied to ground for electrical grounding at a resistance commonly lower than 10 ohms.
What is the accepted method of connection for cathodic protected pipe?
I have installed jumpers on pipe with cathodic protected to ensure continuity. one accepted method of connection is Cad-Welding. See Erico.com
What is the cone of stainless steel rods?
A cone of stainless steel rods was installed downstream of the filter and was found to be effective in discharging the static charges.
Does static discharge in piping?
The static did not discharge completely in over 100 feet of piping following the filter . The operators would see discharge arcs inside the oil when looking down into a truck tanks that were being loaded. There was an incident involving a tank that had residual traces of gasoline from the previous load.