
What is TECK90 used for?
Northern Cables Inc.’s TECK90 is an interlocked armoured cable for use in petro-chemical, pulp and paper, and other industrial application environments. TECK90 can be used in open and concealed wiring, direct burial, and in hazardous locations.
What is Teck cable made of?
Construction. Teck cable is composed of copper conductors sheathed in cross-linked polyethylene, bundled by plasticized PVC, wrapped in interlocking aluminum armour, all sealed by another coat of PVC.
What is Teck 90 cable?
The Teck 90 Cable is made up of bare-copper conductors that come with polyethylene insulation which is cross-linked. This gives this cable type the XHHW rating. The temperature standard range of the Teck cables is usually 90 degrees Celsius in dry and wet locations, with the emergency range set at 130 degrees Celsius.
What is a Teck cable in Canada?
In Canada, teck cable is defined by CSA standard C22.2 No. 131 and carries the type designation of TECK90, the 90 referring to the normal ambient temperature in degrees Celsius that the cable may be used in without de-rating its ampacity.

What is Teck 90 cable used for?
CSA TECK 90 Armoured Power - Multi-Conductor (1000V) Unshielded armoured power cable is used to supply power for lighting, drives, motors and pumps. Interlocked armour replaces the use of conduit for mechanical protection.
Does Teck cable have ground?
TECK90 can be used in open and concealed wiring, direct burial, and in hazardous locations. The insulated conductors are made with cross-linked polyethylene and twisted with an uninsulated ground wire.
Is Teck cable the same as MC cable?
Versatility resides within this dual-rated CSA Teck 90/UL Metal Clad (MC) Cable, which is suitable for powering equipment in harsh environments (including dry, damp or wet locations).
Is Teck cable armored?
Unshielded armoured control cable is used for operation of control automation equipment. Interlocked armour replaces the use of conduit for mechanical protection. Cable can be directly buried, installed in raceways, including cable tray in wet or dry environments.
Where is Teck cable permitted to be installed?
Teck cables with outer jacket may be used for exposed or concealed wiring in wet or dry locations, indoors/outdoors and in corrosive environments. Teck cables are suitable for use in ventilated, non-ventilated and ladder type cable troughs, in ventilated flexible cable ways in both dry and wet locations.
How much does Teck cable cost?
The Teck 90 Aluminum Interlocked Armor Cable is XLP insulated with both an inner and outer PVC jacket for maximum protection and durability. Capable in Direct Earth Burial applications. $1.73 /ft. $2.67 /ft.
How do you hook up a Teck cable to a junction box?
1:283:06Star Teck ST Series Fittings - Thomas & Betts - YouTubeYouTubeStart of suggested clipEnd of suggested clipYou will find it easy to insert the cable through the StarTek fitting and into the enclosure theMoreYou will find it easy to insert the cable through the StarTek fitting and into the enclosure the advantage of the StarTAC fitting. Allows you to easily insert.
Does Teck cable need mechanical protection?
Armoured cables having an overall outer covering, such as Type ACWU and Type TECK, must be provided with mechanical protection where necessary to ensure the outer covering is not subject to mechanical damage as stated in Rule 12-606.
How do you cut a Teck cable?
0:352:52How to strip Teck90 - Outdoor and underground cable - XLPE - YouTubeYouTubeStart of suggested clipEnd of suggested clipAnd you just want to create a slice in the rubber. And then you can run your blade up. Like so youMoreAnd you just want to create a slice in the rubber. And then you can run your blade up. Like so you can peel the exterior.
Can you splice Teck cable?
For professional applications, Splices offer reliability and ease of use when tackling a wide range of installations and voltages. The Tape Teck Splice Kit is designed for use in manholes, direct burial and cable tray applications.
Can Teck cable be used underwater?
A – Yes. When ordered, and as recommended by Heat-Line, an additional 20 ft. (6m) of TECK 90 12-3C WIRE should be added to the total length to allow for the power termination end.
Is Teck cable flexible?
Teck cable, a flexible armoured cable originally designed for use in Canadian mines, has become a key component for the distribution of electricity through a broad range of industrial, commercial and manufacturing facilities.
How do you wire a Teck cable?
1:423:06Star Teck ST Series Fittings - Thomas & Betts - YouTubeYouTubeStart of suggested clipEnd of suggested clipYou will find it easy to insert the cable through the StarTek fitting and into the enclosure theMoreYou will find it easy to insert the cable through the StarTek fitting and into the enclosure the advantage of the StarTAC fitting. Allows you to easily insert.
What type of cable is Teck?
low voltage armoured cableTeck cable is a type of low voltage armoured cable named for the location where it was first developed and used, Teck Township, now known as Kirkland Lake, Ontario.
What is the difference between Type AC90 and type Teck 90 cable?
Type ACWU90 is used for feeders and service entrances, as well as certain dedicated branch circuits in non- combustible buildings. Types AC90, ACWU90 and TECK90 are acceptable for consumer service conductors, although Type AC90 is restricted to services above ground in dry locations.
Does Teck cable need mechanical protection?
Armoured cables having an overall outer covering, such as Type ACWU and Type TECK, must be provided with mechanical protection where necessary to ensure the outer covering is not subject to mechanical damage as stated in Rule 12-606.
What is a Teck 90 cable?
The Teck 90 cable does away with the needs for costly burial or conduit piping. This type of interlocking-aluminum cable was designed with the purpose of demands associated with the petroleum, chemical, paper, pulp, mining and any of the other harsh environments.
What temperature is a teck cable?
The temperature standard range of the Teck cables is usually 90 degrees Celsius in dry and wet locations, with the emergency range set at 130 degrees Celsius. The Teck 90 cable features a bare-ground wire inside its construction. There is also another cable, which has the same application with teck 90 cable, that is mc cable.
Can you use a teck 90 cable?
So if you want to use teck 90 cable, you must know the teck 90 cable price at first. From the major resource and mining industries, which include metal, petrochemical, paper and pulp industries to high rises, commercial buildings and private homes, the Teck 90 can be used for a number of conditions that include some of the following: ...
Is the Teck 90 cable more expensive?
The Teck 90 cables may be more expensive when you compare them to the typical Aluminum-Interlocked products. Yet, this added interior PVC jackets which are found inside the Teck 90 cables is what often makes it one of the more attractive long-term, cost effective solutions across the majority of industries. What’s more, here is also low price acwu cable for sale.
Copper Conductor
Northern Cables Inc.’s TECK90 is an interlocked armoured cable for use in petro-chemical, pulp and paper, and other industrial application environments. TECK90 can be used in open and concealed wiring, direct burial, and in hazardous locations.
Aluminum Conductor
TECK90 is available in 1000-volt constructions from #8 to 750 kcmil in 8000 series aluminum ACM conductor. Cables can be manufactured in single conductor up to 4 conductors. Custom cables are available upon request including composites, vertical riser, and coloured jackets.
What is Tray Cable?
Tray cables are multi-conductor and multi-paired cables generally used in signal and energy transmission with minimum interference, and installation in trays, wireways, troughs, ducts, conduits, and channels.
What is Teck Cable?
Teck cable, known as TECK90 Cable, is CSA approved cable rated 600 to 5kV. Teck cable is found in single and multiple conductor constructions with an inner jacket, aluminum or steel interlocked armor, and a PVC jacket.
How Do They Compare?
There is a lot of overlap between teck cable and tray cable when it comes to their construction. Both can feature bare copper conductors, XLPE or EPR insulation, and PVC jackets. However, there are a few significant differences that set these cables apart as well.
Why is the ampacity of a teck cable not determined?
The reason is that the heat dissipation for a Teck cable in a conduit is «unknown», so the ampacity cannot be determined. As 7another4 mentionned, you must derate the ampacity of the cable, but how? This question is not answered by the CEC.
Which cable has an overall jacket?
Table D1 lists AC90, ACWU90, and some TECK cables as having an overall jacket.
What is the limiting factor in armoured cable installation?
Typically, the limiting. factor in these installations is the sidewall bearing pressure.
What is the radius of a cable bend?
cable and bends with a 1.524 m radius for high-voltage cable. Installations beyond these parameters should have
Can you use armoured cable in conduit?
In my opinion armoured cable is allowed in conduit as per Rule 12-902 (2) as long as fill ratio and pulling tensions are not exceeded. Multiconductor power cables larger than #1/0 installed according to Diagram B4-4 need to follow the ampacity tables D14 A and B. Rule 4-004 (1) (d) and (2) (d) describe the ampacity of metal armoured cables greater than #1/0 in a raceway based on these tables.
Will Eng tips check this out?
The Eng-Tips staff will check this out and take appropriate action.
Can you run a TECK cable through a conduit?
You may run the cable through a duct or conduit but you have to derate the ampacity since there will be a temperature drop in the conduit. You have to know the losses in the armor-eddy current or circulating current if the armor is grounded in more than one point. RE: Running TECK Cable In Conduit.
