what is vss and vpc

by Dr. Gladys Hansen DDS Published 2 years ago Updated 2 years ago
image

vPC:- Control messages are carried by CFS over Peer Link and a Peer keepalive link is used to check heartbeats and detect dual-active condition; VSS:- Control messages and Data frames flow between active and standby via VSL; 10 Helpful. Share. Go to solution.

Full Answer

What is the difference between VSS and VPC on a switch?

Correct, VSS is only for Catalyst series switches and vPC is for the Nexus switches which are mainly designed to be used in data centers. As for as connecting the Cisco to Dell and other vendors, you can use LACP for bundling multiple uplinks in one logical connection. LACP is standard and used pretty much by all vendors.

What is the difference between VPC and Nexus?

Nexus is mainly used for data center and VSS for campus environment. The max number of devices you can use for both VPC and VSS is 2. As far as the difference, VSS has one control plane vs VPC 2 different ones. With VSS you eliminate the use of VRRP, HSRP, etc.. with VPC you still have to use one HSRP or VRRP.

What is the difference between a 6500 and a VPC?

VSS is the 6500 technology to logically combine two physically separate chassis. As you point out vPC is a Nexus technology, the Catalyst equivalent is MEC (Multi-chassis Ether Channel). From your message you are correct in thinking that using etherchannel from the TOR switches to the core is the correct solution.

What is the catalyst equivalent of VPC?

As you point out vPC is a Nexus technology, the Catalyst equivalent is MEC (Multi-chassis Ether Channel). From your message you are correct in thinking that using etherchannel from the TOR switches to the core is the correct solution. I am not clear on why you want vPC/ MEC...are you planning on deploying a large core switch at each remote site??

What is VPC and VSS?

Is HSRP required for VPC?

image

What is VSS in networking?

Virtual Switching System 1440 (VSS) ▪ Virtual Switching System consists of two Cisco Catalyst 6500 Series defined as. members of the same virtual switch domain. ▪ Single control plane with dual active forwarding planes.

What is a vPC on Nexus?

vPC's, or Virtual Port Channels, are a Cisco Nexus technology. They are used to connect layer-2 devices to two switches at once. This makes it possible to create a highly available environment in the data centre. If one switch fails, the other one continues to operate.

What is the difference between VSS and stacking?

Functionality wise, there is no difference. Stackwise Virtual and VSS are technically the same. They are called what they are because of marketing. In both instances, two physical chassis for a single logical unit which makes management easier and enables cross-chassis Etherchannel.

What is the difference between vPC and port channel?

Here you can see that Virtual Port channel (vPC) is configured using the interfaces of two switches. One of the key difference between the two technologies (port-channel and virtual port-channel ) is that port channels support both Layer 2 and Layer 3. vPC on the other hand only supports Layer 2.

What is the purpose of vPC?

Amazon VPC enables you to build a virtual network in the AWS cloud - no VPNs, hardware, or physical datacenters required. You can define your own network space, and control how your network and the Amazon EC2 resources inside your network are exposed to the Internet.

What is vPC in Nexus and what are the benefits?

VPC is a feature available for Nexus switches. You can bundle links from two different switches that are running the vpc feature and config. It helps with doubling the bandwidth and creates a loop free topology (from STP perspective). VSS does the same thing for IOS switches using MEC.

How many control planes are there in VSS?

one Control planeIn Virtual Switch Mode, while only one Control plane is active, both Data Planes (Switch Fabric's) are active, and as such, each can actively participate in the forwarding of data …

How does Cisco VSS work?

A VSS is network system virtualization technology that pools multiple Cisco Catalyst Switches into one virtual switch, increasing operational efficiency, boosting non-stop communications, and scaling system bandwidth capacity.

What is VSS in vmware?

VSS detects which VMs are logically connected to which virtual ports and uses that information to forward traffic to the correct VMs -- it emulates a physical hardware switch. VSS comes free with an ESXi installation and you can create several vSSes on each ESXi host.

How many vPC domains can a switch have?

The maximum number of switches in a vPC domain is two. The maximum number of vPC peers per switch or VDC is one. When Static routing from a device to vPC peer switches with next hop, FHRP virtual IP is supported. Dynamic routing adjacency from vPC peer switches to any Layer3 device connected on a vPC is not supported.

Is vPC active active?

In data plane terms, HSRP with vPC is active/active. Both of the switches forward traffic.

Is LACP and port channel the same thing?

The Link Aggregation Control Protocol (LACP), described by IEEE 802.3ad, defines a method for two switches to automatically establish and maintain link aggregation groups (LAGs, also called channel groups or port channels). Using LACP, a switch can configure LACP-compatible ports into a dynamic LAG.

What is vPC and VDC in Nexus?

VDC - Virtual Device Content. 7K support up to four VDCs on a pair of 7K hardware. You can sign different hardware resources to the different VDCs. VPC - Virtual PortChannel. Which very like VSS (Virtual Switch).

How do I create a vPC on Nexus?

Cisco Nexus vPC Configuration ExampleStep 1: Enable the vPC Feature and Configure the vPC Domain ID on Both Switches. ... Step 2: Choose a Peer Keepalive Deployment Option. ... Step 3: Establish the vPC Peer Keepalive Link. ... Step 4: Configure the vPC Peer-Link. ... Step 5: Configure Individual vPCs to Downstream Devices.More items...

What is AWS vPC?

Amazon Virtual Private Cloud (Amazon VPC) enables you to launch AWS resources into a virtual network that you've defined. This virtual network closely resembles a traditional network that you'd operate in your own data center, with the benefits of using the scalable infrastructure of AWS.

How do I check my vPC on Nexus?

To verify vPCs using the CLI, perform one of these tasks:Purpose. Command. ... show running-config vpc. Checks the status of the vPCs. ... show vpc peer-keepalive. Verifies that the vPC peers have the identical type-1 parameters.show vpc consistency-parameters. ... show tech-support vpc. ... show port-channel summary.

What is the difference between VSS and VPC? - Quora

Answer: difference between VSS and VPC: The difference between VSS and VPC is that, VSS operates at block level of the file system. VPC is to a certain level between different users using the resources. A Volume Shadow Copy Service-based backup (VSS-based backup) is a Windows service that captu...

What is the difference between VSS and vPC?

Basically VSS and Vpc both are used to create multi chasis etherchannel 1) vPC is Nexus switch specific feature,however,VSS is created using 6500 series switches

What is functional difference between VSS and VPC in Nexus

Solved: Dear All, As we know Nexus is expensive, If we are just talking on VPC function in Nexus, what is functional difference between VSS and VPC ? If we use VSS, it could be installed in several Cisco devices, which are very cheaper.

VPC vs VSS - Cisco Community

Hello Everyone , I am looking for a suggestion and if you could confirm few points that I am going to mention I have a network infrastructure that spread over many sites , those sites are connected by MPLS Network " Hub & Spoke " . The current local infrastructure in each site is considered as...

STACKWISE VS VSS VS VPC VS MCLAG

raymondcoward, are you sure about VPC?I though VPC was to configure multiple devices to appear as one device for the neighbouring devices for the purpose of traffic load sharing.

VPC vs VSS » Network Interview

SNo: VPC: VSS: 1: Feature specific to Nexus: Feature specific to catalyst 6500,4500 Series: 2: Separate control plane for both switches. 2 Switches merge to form 1 logical Switch with a single control plane.

What is the difference between VPC and VSS?

What is the difference between VSS and vPC? 2) In VSS there will be single control plane for both the switches, where as in vPC there will be separate control plane for every switch. 3) VSS can support L3 port-channels across multiple chassis,however , vpc is used for L2 port-channels only.

How many switches are managed in VSS?

6) In VSS, only one logical switch has be managed from management and configuration point of view.That means, when the switches are put into VSS, now there is only one IP which is used to access the switch. They are not managed as separate switches and all configuration are done on active switch.

Is there a control plane for VSS?

2) In VSS there will be single control plane for both the switches, where as in vPC there will be separate control plane for every switch.

What is VSS chassis?

VSS is the 6500 technology to logically combine two physically separate chassis. As you point out vPC is a Nexus technology, the Catalyst equivalent is MEC (Multi-chassis Ether Channel).

Is VSS the same as VPC?

I check and I saw that VSS is kind of similar to VPC in Catalyst . based on search result , it seems that it is available only on Catalyst 6500 .

Is VSS only for Cisco?

Correct, VSS is only for Catalyst series switches and vPC is for the Nexus switches which are mainly designed to be used in data centers. As for as connecting the Cisco to Dell and other vendors, you can use LACP for bundling multiple uplinks in one logical connection. LACP is standard and used pretty much by all vendors. As for which switch to use, read the datasheets for multiple platforms and compare to make sure the switch meets your requirement before purchasing.

Can a port channel be used for multiple switches?

Both are used basically to support multi-chassis ether-channel that means we can create a port-channel whose one end is device A,however, another end is physically connected to 2 different physical switches which logically appears to be one switch.

Is a VSS switch managed separately?

That means, when the switches are put into VSS, now, there is only one IP which is used to access the switch. They are not managed as separate switches and all configuration are done on active switch. They are managed similar to what we do in stack in 3750 switches,however, in vPC, the switches are managed separately.

What is the difference between VSS and VPC?

The difference between VSS and VPC is that, VSS operates at block level of the file system. VPC is to a certain level between different users using the resources.

What is a VPC?

A virtual private cloud (VPC) is an on-demand configurable pool of shared computing resources allocated within a public cloud environment, providing a certain level of isolation between the different organizations (denoted as users hereafter) using the resources.

What is a VPS server?

A VPS (Virtual Private Server) is a rented virtual machine running on someone else’s hardware. AWS EC2 can be thought of as a VPS, but the term is usually used to describe low-cost products offered by lots of other hosting companies.

What is VPC and VSS?

Both VPC and VSS are used basically to support multi-chassis ether-channel that means we can create a port-channel whose one end is device A, however, another end is physically connected to 2 different physical switches which logically appears to be one switch.

Is HSRP required for VPC?

HSRP is required. First Hop Redundancy Protocol like HSRP not required. Separate instance of STP, FHRP, IGP, BGP etc. will be required on each physical Switch of VPC. Same instance of STP, FHRP, IGP, BGP etc. will be used on each physical Switch of VSS. Both the switches are active and work individually.

image

1.VPC vs VSS - IP With Ease

Url:https://ipwithease.com/vpc-vs-vss/

33 hours ago  · Basically VSS and Vpc both are used to create multi chasis etherchannel. 1) vPC is Nexus switch specific feature,however,VSS is created using 6500 series switches. 2) In VSS …

2.What is the difference between VSS and vPC?

Url:https://www.kareemccie.com/2017/07/what-is-difference-between-vss-and-vpc.html

30 hours ago  · VSS is the 6500 technology to logically combine two physically separate chassis. As you point out vPC is a Nexus technology, the Catalyst equivalent is MEC (Multi-chassis …

3.Videos of What is VSS and VPC

Url:/videos/search?q=what+is+vss+and+vpc&qpvt=what+is+vss+and+vpc&FORM=VDRE

12 hours ago The difference between VSS and VPC is that, VSS operates at block level of the file system. VPC is to a certain level between different users using the resources. A Volume Shadow Copy …

4.VPC vs VSS - Cisco Community

Url:https://community.cisco.com/t5/switching/vpc-vs-vss/td-p/3845076

24 hours ago  · # What is the purpose of EtherChannel?ASICVirtual Device Contexts (VDC).How does VDC work in Nexus?What is the difference between VSS and VPC?

5.VSS vs VPC (difference between VSS and vPC) - Blogger

Url:https://mycciedatacenter.blogspot.com/2013/06/vss-vs-vpc-difference-between-vss-and.html

29 hours ago vPC (Virtual Port-Channel), also known as multichassis EtherChannel (MEC) is a feature on the Cisco Nexus switches that provides the ability to configure a Port-Channel across multiple …

6.What is the difference between VSS and VPC? - Quora

Url:https://www.quora.com/What-is-the-difference-between-VSS-and-VPC

25 hours ago  · From an operational standpoint, VSS presents a single management point, 2-4 SUPs with one Active. One data plane, one control plane. VPC is One data plane, 2 control …

7.# EtherChannel? (VDC).How does VDC work in Nexus?

Url:https://www.youtube.com/watch?v=IAGrkoPiv_0

14 hours ago VPC is a feature available for Nexus switches. You can bundle links from two different switches that are running the vpc feature and config. It helps with doubling the bandwidth and creates a …

A B C D E F G H I J K L M N O P Q R S T U V W X Y Z 1 2 3 4 5 6 7 8 9