If you see an unused opening close the door and notify maintenance for repair. When a circuit breaker is removed from a breaker panelboard it leaves an unused opening. Every manufacturer of panelboards makes what is called a filler plate to cover this opening.

There are only two feasible means to fill an unused opening in a panelboard. An identified blank from the manufacturer is one option. The most effective option is to install a spare circuit breaker. It is important to note that an unused opening for a conduit or cable assembly will result in the same citation.Nov 16, 2018

Full Answer

How to make plugs tighter?

Why do you cover electrical openings?

Where are knockout plugs required?

Who is Reuben Saltzman?

Can you comment on a web link?

See 2 more

About this website

What must be done with unused openings in electrical boxes?

(b) Unused openings in cabinets, boxes, and fittings shall be effectively closed.

Can you leave unused breakers in panel?

Can an unused (spare) circuit breaker remain in an electrical panel or does it have to be removed? Spares do not have to be removed from the panel. The National Electrical Code (NEC) simply requires that they be identified in the circuit directory.

What is used to close unused openings?

Unused Openings.A:Any material may be used to close unused openings in electrical boxes.B:Blank spaces in the deadfront of a panelboard shall only be closed by the use of a spare circuit breaker.C:Knockouts in boxes may be closed by the use of electrical tape.D:Blank spaces for circuit breakers must be closed.

What section of the NEC covers the requirements for dealing with unused openings in A box?

370-18 Unused Openings Unused cable or raceway openings in boxes and conduit bodies must be closed so that the protection provided at least equals that of the wall of the box or conduit body. Even though duct tape is similar in color to metal boxes, it does not provide protection equivalent to the wall of the box.

Should you turn off unused breakers?

Yes, you should turn off your AC circuit breaker when it's not in use, especially during the winter season. By doing so, you can reduce phantom power consumption, thus saving on your electrical bills. Because even though this consumption is barely noticeable, little savings here and there will go a long way.

What do you do with unused live wire?

Terminate them in a proper box, cap them and apply a tape tag with the circuit breaker number that energises them, cover with a blank cover.

What is stated about unused openings in boxes and raceways?

Unused openings in boxes, raceways, auxiliary gutters, cabinets, equipment cases, or housings shall be effectively closed to afford protection substantially equivalent to the wall of the equipment.

What is stated about unused openings in boxes and raceways Article 110?

(A) Unused Openings Unused openings, other than those intended for the operation of equipment, those intended for mounting purposes, or those permitted as part of the design for listed equipment, shall be closed to afford protection substantially equivalent to the wall of the equipment.

Why must every hole in a circuit breaker panel be covered?

Keep Panels Clean Another reason you need to cover unused openings is that it keeps the interior of the electrical equipment from being exposed to the dirt, dust and other contaminates you may have at your facility. Allowing the interior of a circuit breaker panel to become dirty could cause additional safety issues.

What does the NEC state about unused openings in nonmetallic boxes?

(A) Unused Openings. Unused openings, other than those intended for the operation of equipment, those intended for mounting purposes, or those permitted as part of the design for listed equipment, shall be closed to afford protection substantially equivalent to the wall of the equipment.

How do you fill missing knockouts in electrical box?

0:351:161-1/2" Knockout Seal for Electrical Box or Panel KOS-150 - YouTubeYouTubeStart of suggested clipEnd of suggested clipInside the open knockout hole Center the outside plate on the outside of the open knock out of holeMoreInside the open knockout hole Center the outside plate on the outside of the open knock out of hole ensuring. That the backer bar catches on the inside of the box.

How many entrances and exits must you have in a working space around electrical equipment?

At least one entrance not less than 24 inches (610 mm) wide and 6 feet 6 inches (1.98 m) high shall be provided to give access to the working space about electric equipment.

How do you store breakers?

SHORT TERM STORAGELay the breaker on wooden blocks. Remove the pins to disconnect the breaker from the boom.Remove the tool and ensure the retaining pins, bushings and piston bottom are well greased.Reinstall the tool.Cover with a tarp.

Why you should never ignore a circuit breaker in your home that constantly trips?

Don't Ignore a Tripping Circuit Breaker Your circuits are only able to handle up to a certain level of voltage. Beyond this voltage, you run the risk of starting an electrical fire. This is why the circuit breaker trips, shutting off the flow of electricity in your home.

Do circuit breakers have a shelf life?

Longevity of Circuit Breakers The Consumer Product Safety Commission outlines that the average circuit breaker lifespan is around 30 – 40 years. On the other hand, some experts instead estimate the lifespan of circuit breakers to be around 15 – 20 years instead.

How do you remove unused circuit breakers?

Removing a circuit breaker from your home's electrical service panel is an easy job that takes just a few minutes....InstructionsTurn Off the Main Breaker. ... Unscrew the Panel Cover. ... Remove the Cover. ... Test for Power. ... Turn Off the Branch Breaker. ... Rock the Breaker Back. ... Pull the Breaker Out.More items...•

What is a missing knockout or open knockout in an electric panel box ...

McGarry and Madsen Inspection. 16822 SE 92nd Danna Avenue, The Villages, FL 32162. www.thevillagesbestinspector.com • Comments or questions to [email protected]. While we hope you find this series of articles about home inspection helpful, they should not be considered an alternative to an actual home inspection by a local inspector.

How to Remove a Knockout from Your Box or Panel

When wiring your home, it may be necessary to access your breaker box to create more breaker locations. Knockouts are a prefabricated hole located in your circuit breaker or panel box. When circuit panels are installed, there are empty spaces left available for future use.

What is NEC 408.7?

The requirement you are referring to is Section 408.7, Unused Openings. Where an unused opening exists, it must be closed to prevent contact with energized conductors or circuit parts. This NEC requirement recognizes identified closures, which would include blanks identified for the use provided by the panelboard manufacturer.

How much is the penalty for OSHA violations?

As of Jan. 2, 2018, the penalty for serious OSHA violations is $12,934. Once a serious citation is received and settled, the contractor enters a five-year window in which a similar citation will be considered as a “repeat or willful” violation with a penalty of $129,336. While a serious OSHA citation may seem expensive, it pales in comparison to increased cost of workers compensation premiums, which can put a contractor out of business. See the NECA Guide to Temporary Power, which provides installers with all the information needed to comply with OSHA and NEC requirements.

What is section 300.5?

Section 300.5 (G) is a general sealing requirement for underground raceways through which moisture may contact live parts. Section 300.7 (A) requires seals were portions of a raceway or sleeve are subject to different temperatures and where condensation is known to be a problem.

What is a 404.11 switch?

Section 404.11 specifically permits a hand-operable circuit breaker equipped with a lever or handle. All molded-case circuit breakers have an external handle to move the device into the on or off position.

What is 240.81?

Section 240.81 requires that circuit breakers indicate whether they are in the open (off) or closed (on) position and requires handles operated vertically have the “up” position be the “on” position.

What is a duplex receptacle?

This occurs where a single device such as a du plex receptacle is supplied by two separate branch circuits. In this case, the conductor tabs may be removed, and each contact device on the duplex receptacle is supplied from a different branch circuit.

Where is the water supply located in a washer?

The water supply and discharge are located in the wall above the washer. The homeowner uses this washer for arts and crafts, tie-dye shirts, etc. The home already has a laundry area with GFCI-protected receptacles. Yes, the receptacle must be GFCI-protected as required in 210.8 (A) (10).

A common code violation we see during electrical inspections and routine electrical maintenance is an improper covering for an unused opening. The National Electric Code states

A common code violation we see during electrical inspections and routine electrical maintenance is an improper covering for an unused opening. The National Electric Code states:

Section 408.7 Unused Openings: Where an unused opening exists, it must be closed to prevent contact with energized conductors or circuit parts

Section 408.7 Unused Openings: Where an unused opening exists, it must be closed to prevent contact with energized conductors or circuit parts.

How to make plugs tighter?

If you want to make the plug super tight and impossible to remove, you could bend the tabs inside the box with a screwdriver. I'm sure some electricians would say this should always be done. The photo below left shows the tabs in their normal position, and the photo below right shows the tabs bent out.

Why do you cover electrical openings?

Covering these openings helps to prevent accidental shocks (think of kids), helps to prevent hot sparks from escaping if something goes wrong inside the enclosure, and helps to prevent pests from entering. It happens.

Where are knockout plugs required?

For Truth-in-Housing evaluations, missing knockout plugs are required repair items in Bloomington, Hopkins, Robbinsdale, and South Saint Paul. They're considered a hazard (H) in Saint Paul, and they're a suggested correction (SC) in Minneapolis.

Who is Reuben Saltzman?

Reuben Saltzman is a second-generation home inspector with a passion for his work. Naturally, this blog is all about home inspections and home-related topics in the Twin Cities metro area. In addition to working at Structure Tech, he is also a licensed Truth-In-Sale of Housing Evaluator in Minneapolis, Saint Paul and several other cities.

Can you comment on a web link?

Comments with web links are not permitted.

How to make plugs tighter?

If you want to make the plug super tight and impossible to remove, you could bend the tabs inside the box with a screwdriver. I'm sure some electricians would say this should always be done. The photo below left shows the tabs in their normal position, and the photo below right shows the tabs bent out.

Why do you cover electrical openings?

Covering these openings helps to prevent accidental shocks (think of kids), helps to prevent hot sparks from escaping if something goes wrong inside the enclosure, and helps to prevent pests from entering. It happens.

Where are knockout plugs required?

For Truth-in-Housing evaluations, missing knockout plugs are required repair items in Bloomington, Hopkins, Robbinsdale, and South Saint Paul. They're considered a hazard (H) in Saint Paul, and they're a suggested correction (SC) in Minneapolis.

Who is Reuben Saltzman?

Reuben Saltzman is a second-generation home inspector with a passion for his work. Naturally, this blog is all about home inspections and home-related topics in the Twin Cities metro area. In addition to working at Structure Tech, he is also a licensed Truth-In-Sale of Housing Evaluator in Minneapolis, Saint Paul and several other cities.

Can you comment on a web link?

Comments with web links are not permitted.

1.Unused Opening Citation, Tamper Resistance and More

Url:https://www.ecmag.com/section/codes-standards/unused-opening-citation-tamper-resistance-and-more

32 hours ago  · There are only two feasible means to fill an unused opening in a panelboard. An identified blank from the manufacturer is one option. The most effective option is to install a …

2.Expensive Osha Citation For Unused Openings

Url:https://twielectric.com/expensive-osha-citation-for-unused-openings/

15 hours ago  · As home inspectors we see them all the time ”unused openings” in electrical boxes and electric panels (panelboards) that should always be covered. Plug for knockouts. These …

3.How to Fill Missing Knockouts in Electric Boxes - Star …

Url:https://www.startribune.com/how-to-fill-missing-knockouts-in-electric-boxes/197744181/

32 hours ago Section 408.7 Unused Openings: Where an unused opening exists, it must be closed to prevent contact with energized conductors or circuit parts. The NEC further states that there …

4.Unused openings for circuit breakers and switches shall

Url:https://forums.mikeholt.com/threads/unused-openings-for-circuit-breakers-and-switches-shall.10763/

34 hours ago  · As it stands now, even with the 2005 code if the unused opening is not for cables, raceways, or circuit breakers or switches, the openings are not required to be closed. …