The gas meter is typically located on either the side or the rear of the house. For businesses and multi-family residences, the meter may be located inside of the building. If you need assistance finding your meter, please reach out to your building manager. The gas meter will look similar to those pictured below.
Full Answer
What do natural gas meters look like?
0:322:02This these meters normally have four dials and a horizontal line occasionally. They'll have more orMoreThis these meters normally have four dials and a horizontal line occasionally. They'll have more or fewer dials. But the way you read them is the same. The hands on the dial is number one.
How can I monitor my natural gas usage?
To monitor the use of natural gas, modules are attached to gas meters to record gas usage daily. The system periodically transmits the recorded data to the power company via a communications network that may be wireless, travel through the power lines or via radio communication.
How many types of gas meters are there?
There are four natural gas meter types often used for flow measurement. They are mass flow meters, velocity flow meters, differential pressure, and PD meters.
What is a gas meter called?
Orifice meters are a very commonly used type of meter, and because of their widespread use, the characteristics of gas flow through an orifice meter have been closely studied.
How do I find my gas meter?
Gas meters located inside are normally found inside a kitchen (it will normally be concealed in a cupboard) or a hallway, and will most likely be inside a mounted meter cupboard or a meter box. If you live inside a flat, then there will be multiple gas meters located in a single place, such as a shared utility room.
How do I find my gas meter number?
Your Meter Point Reference Number (MPRN) can be found on your gas bill. Usually, this is located on the first page of your bill or on the back of the front page and is up to 10 digits long.
Who owns the gas meter in my house?
Gas meter boxes can be installed by the homeowner before the supplier installs the supply, or the gas supplier might install the meter box through some agreement with the consumer. However, once the meter box is installed it appears that the consumer (usually the property owner) is responsible for its maintenance.
Can you buy your own gas meter?
Smaller gas consumers are permitted to own (or to arrange for provision of) their own gas meter but must also ensure that it is properly maintained to ensure its safety and accuracy.
How do I know what kind of meter I have?
You're looking for your meter box, which is most likely white. If you live in a flat or an apartment, you might find your meter on the ground floor. Each meter should be labelled with the corresponding flat – if not you'll need to contact your landlord and they'll be able to tell you where it is.
What are the 2 types of gas meters?
They generally come in two different types; either metric or imperial, with metric generally having five main numbers and imperial having only four main numbers.
Is it better to have gas meter inside or outside?
Indoor gas meters increase the risk of an indoor gas leak, require special venting, and can make it more dangerous to shut off gas in an emergency.” The risk, as stated above, is indoor gas leaks. To minimize the risk, we recommend that all gas meters be installed outdoors.
What size is a domestic gas meter?
Typically installed gas meter sizes range from 175 cf/h to 275 cf/h.
What is G4 meter?
The gas meter UG-G4 is designed for measurement of gas supplied to apartments where maximum consumption of gas is equivalent to 6m3/h of air of density of 1,2 kg/m3. The gas meters can be used for. measurement of: ● Natural gas. ● City gas.
What is a rotary gas meter?
The rotary gas meters are positive displacement meters, designed to measure quantity of gas, for custody transfer or technical measurement applications. The devices are mainly applied for gas flow ranges from 0.2 up to 650 m³/h, and the pressure range up to 20 bar.
What size is a domestic gas meter?
Typically installed gas meter sizes range from 175 cf/h to 275 cf/h.
How does a residential gas meter work?
A gas meter is driven by the force of the moving gas in the pipe, and also turns faster as the flow increases. Each time the dial with the lower value makes one complete revolution, the pointer on the next higher value dial moves ahead one digit.
How does a gas meter work?
A gas meter is driven by the force of the moving gas in the pipe, and also turns faster as the flow increases. Each time the dial with the lower value makes one complete revolution, the pointer on the next higher value dial moves ahead one digit. When reading a gas meter, read and write down the numbers as shown on the dials from left to right ...
How is natural gas measured?
Natural gas is commonly measured by the cubic foot, and you are billed by the thousands of cubic feet (MCF) or hundreds of cubic feet (CCF). You may also be billed by the therm, which is about the same as a CCF or 100 cubic feet. To measure the amount of electricity or gas that you use, the utility installs a meter between ...
How to read an electric meter?
When reading an electric meter, read and write down the numbers as shown on the dials from right to left. When the pointer is directly on a number, look at the dial to the right. If it has passed zero, use the next higher number. If it has not passed zero, use the lower number.
How does an electric meter work?
The standard electric power meter is a clock-like device driven by the electricity moving through it. As the home draws current from the power lines , a set of small gears inside the meter move. The number of revolutions is recorded by the dials that you can see on the face of the meter.
How to read gas meter?
When reading a gas meter, read and write down the numbers as shown on the dials from left to right (opposite of an electric meter). It is important to note that on both types of meters, the hands of adjacent dials turn in opposite directions to each other.
What is the unit of measure of electricity?
Electric Meters. The basic unit of measure of electric power is the watt. One thousand watts are called a kilowatt. If you use one thousand watts of power in one hour you have used a kilowatt-hour (kWh). Your electric utility bills you by the kWh.
What is the difference between a month's reading and the next?
The difference between one month's reading and the next is the amount of energy units that have been used for that billing period.
Why do we use temperature compensation meters?
Temperature compensation meters are used more often with LPG gas because LPG tanks are located above ground where the tanks can be directly and quickly affected by the outside temperature.
Why are gas meters more difficult to measure than liquids?
A. Gases are more difficult to measure than liquids, because measured gas volumes are highly affected by temperature and pressure. Gas meters measure a defined volume, regardless of the pressurized quantity or quality of the gas flowing through the meter.
What does LT mean in gas light?
A. Years ago the LT referred to the old gas light systems. The LT is simply referring to the size of a particular fitting. For example:
What is a natural gas meter?
The natural gas meter outside your home measures the amount of natural gas your home consumes. It’s important to know a few things about your gas meter when monitoring your usage or in the event of an emergency. Most natural gas meters on the Jackson Energy Authority system are dial meters that have a reading window with 2 small dials ...
How many dials are there on Jackson gas meters?
Most natural gas meters on the Jackson Energy Authority system are dial meters that have a reading window with 2 small dials and 4 larger dials. Each of the larger dials should have numbers from 0-9 with a black sweep hand that rotates according to the directional arrow above the dial.
What is the number to call Jackson Energy Authority?
Call Jackson Energy Authority at 731-422-7500 as the restoration of gas service requires many safety steps. During these steps, crews will come out to inspect the meter on your property and ensure that no gas is flowing in the lines. Once all safety steps are complete, crews will return the flow of gas. As a reminder, Jackson Energy Authority ...
Do Jackson Energy employees carry identification?
As a reminder, Jackson Energy Authority employees carry proper identification with them at all times. Customers should always ask to see identification before allowing an employee inside the home.
Who is responsible for everything downstream of a meter?
Everything downstream of the meter, indicated by the yellow line, is the responsibility of the homeowner/customer.
How is CSST protected?
CSST systems shall be protected in accordance with the manufacturer's installation instructions. Where passing through an outside wall, the piping shall also be protected against corrosion by coating or wrapping with an inert material. Where piping is encased in a protective pipe sleeve, the annular space between the piping and the sleeve shall be se aled.
How far above ceiling should a piping outlet be?
The unthreaded portion of piping outlets shall extend not less than l inch (25 mm) through finished ceilings and walls and where extending through floors or outdoor patios and slabs, shall not be less than 2 inches (51 mm) above them.
How high should a piping be above ground?
All piping (including CSST) installed outdoors shall be elevated not less than 31/2 inches (152 mm) above ground and where installed across roof surfaces, shall be elevated not less than 31/2 inches (152 mm) above the roof surface. Piping installed above ground, outdoors, and installed across the surface of roofs shall be securely supported and located where it will be protected from physical damage.
How far can a gas meter arc?
3 feet for non-utility gas meters and electric service equipment that can create an arc when operated.
What is CSA B149.1?
Rule 2-326 states that the clearance between arc-producing electrical equipment and a combustible gas relief device or vent shall be in accordance with the requirements of CSA B149.1, “Natural gas and propane installation code”, which uses the terms “source of ignition” and “discharge openings of relief devices”.
How far from the outside corner of a regulator vent?
If the regulator relief vent is less than 12" from any outside corner, then the minimum clearances specified in this table must be maintained.
How deep is a gas line trench?
Depth includes 4 inches of bedding sand under gas line & 6 inches of sand shading over the gas line, & typical excavation trench width of 12 inches. Backfill must be free of sharp objects and must not contain rocks larger than 8", or increase sand shading depth to 12 inches.