Check Valve Located at the top of the pump to prevent back flow into pump and hold the head of water in the system. Where do you put a check valve on a submersible pump? In submersible pump applications, the first check valve should be installed directly on the discharge head of the pump or maximum one pipe length (20 feet) above pump.
Where do you put a check valve on a well?
Normally, the first check valve should be installed on or directly above the pump. If you have a slow producing well that pumps a little air from time to time, the first check should be installed 5 feet or so above the pump to allow the pump to purge itself of air more easily.
What is a check valve on a submersible well?
The check valve will help your water system maintain pressure when the pump shuts off and also prevent backspin, upthrust, and water hammer. It is recommended that at least one check be installed in all submersible well pump installations. Many well pumps have built-in check valves. Where is the check valve on a submersible well?
Do I need a check valve on my water pump?
Even if a pump does have a built-in check valve, we recommend that a check valve be installed in the discharge line within 25 feet of the pump and below the draw down level of the water supply.
How far above the pump should a check valve be installed?
If you have a slow producing well that pumps a little air from time to time, the first check should be installed 5 feet or so above the pump to allow the pump to purge itself of air more easily. A check valve should never be installed more then 25 feet above the lowest pumping level in the well.

Does a submersible well pump need a check valve?
Check valves permit water flow only in one direction, and are required on all submersible pump installations. Their purpose is to prevent the water in the column above the pump and in the pressure tank from draining back into the well when the pump shuts off.
Where should a check valve be installed?
Check valve can be installed in horizontal or vertical piping runs, with the flow running upward. Mounting for vertical installations is critical.
Does a submersible pump have a built-in check valve?
Many submersible pumps come with a built-in check valve, however if this is not the case, a line check valve should be installed in the discharge line within 25 feet of the pump and below the draw down level of the water supply.
Where does the check valve go on a pump?
0:406:12Right into the base. Or the discharge port or outlet of the pump.MoreRight into the base. Or the discharge port or outlet of the pump.
How close can a check valve be to a pump?
25 feetEven if a pump does have a built-in check valve, we recommend that a check valve be installed in the discharge line within 25 feet of the pump and below the draw down level of the water supply.
Does the check valve go before or after the pump?
Check valves also protect the pumps from harm or leakage, so it makes for good practice to install check valves after the pump to prevent any backflow.
Does deep well need check valve?
A Check Valve Is Required For A Water Well. It's important to understand the components that make up your homes water system in order to maintain it and keep clean fresh water flowing safely into your home.
How far above sump pump should check valve be installed?
Best height ( unless owner's manual states otherwise) is two to three feet off of the top of the sump pit. This way your sump pump motor doesn't have to work as hard as when your check valve is in lower position. It will open easier due to the reduced weight of water above it.
How do you install a check valve on a pump?
2:253:28The bottom section. And I make sure that's nice and parallel. Nice and squared up and tighten it upMoreThe bottom section. And I make sure that's nice and parallel. Nice and squared up and tighten it up by hand. Once I get the knot tighten by hand I can then make sure everything's straight.
When should a check valve be installed?
Check valves are necessary if there is a risk of condensate backflow. For example, when a trap discharges into a common condensate collection line, there is the potential risk of backflow from condensate discharged from other traps, so as a rule a check valve should be installed.
Is it OK to have 2 check valves on a sump pump?
So with two check valves in parallel, you protect against the stuck-closed scenario (as it is unlikely that both check valves will fail in the same manner), but are actually more likely to have a stuck-open fault, since if either check valve fails open the discharge water can flow back into the sump well.
When should a check valve be installed?
Check valves are necessary if there is a risk of condensate backflow. For example, when a trap discharges into a common condensate collection line, there is the potential risk of backflow from condensate discharged from other traps, so as a rule a check valve should be installed.
How far from sump pump should check valve be installed?
The most suitable location for a sump pump check valve is between 8" up from the pumps discharge to approximately 12" above floor level. Installation above the floor level is convenient for easy inspection, servicing, or replacement of the valve.
Where should a backflow preventer check valve be installed?
You should have your backflow prevention assembly installed inside an above-ground enclosure. It's the safest and most cost-effective place to put it. Installing your backflow preventer above ground in an outdoor enclosure allows you to protect your backflow preventer and maintain easy access to it.
How many check valves do you need?
one check valveWe recommend using only one check valve or foot valve in a pump system. A foot valve should be at the inlet to the suction line of turbine, centrifugal, and jet pumps. A check valve should be placed as close as possible to the discharge of a submersible pump.
How far away from pump should check valve be installed?
Even if a pump does have a built-in check valve, we recommend that a check valve be installed in the discharge line within 25 feet of the pump and below the draw down level of the water supply. Although installers have different opinions, in deep wells we recommend that check valves be installed every 200 feet to distribute the weight on each valve.
Why do you need a check valve?
Do I need a check valve? A check valve is a valve that is used to prevent backflow in a piping system. The pressure of the liquid passing through the pipe will open the valve, while any reversal of flow will close the valve. The check valve will help your water system maintain pressure when the pump shuts off and also prevent backspin, upthrust, ...
Why do you need a check valve for a well pump?
The check valve will help your water system maintain pressure when the pump shuts off and also prevent backspin, upthrust, and water hammer. It is recommended that at least one check be installed in all submersible well pump installations. Many well pumps have built-in check valves.
What causes a pump to spin in reverse?
Backspin. When the motor stops, water in the drop pipe can flow down the discharge pipe when there is no check valve or a failed check valve. The flow can cause the pump to rotate in the reverse direction.
What type of check valve do I want?
What type of check valve do I want? Swing type check valves should never be used in a submersible well pump installation. Swing type check valves have a slower reaction time and can cause water hammer. Spring loaded check valves should be used as they close quickly and thus help prevent water hammer. It should be properly sized to meet the pump’s flow and pressure conditions. The check valves pressure rating must exceed the maximum pressure of the pump.
What happens if a pump starts while backspinning?
If the pump starts while it is backspinning, it can cause an excessive force that can break the pump shaft, cause impeller damage, or cause bearing damage. Upthrust. With a failed check valve or no check valve, the pump will start with zero head pressure.
What causes a vacuum in a pump?
Water Hammer. A failed or leaking check valve can cause a vacuum in the discharge piping. When the pump starts, water moving at a very high velocity fills the void and strikes the stationary water in the piping above it, causing a hydraulic shock. The shock can split pipes, break joints, or damage the pump and motor. YouTube.
What causes a submersible pump to backspin?
This can cause the pump to rotate in a reverse direction causing backspin. If the motor is started while it is in this state, ...
What is the function of check valves in a water pump?
Properly located and operating check valves will hold water pressure in the system when the pump stops and ensure smooth and trouble-free operation of the system, preventing backspin, upthrust and waterhammer, all of which can cause damage and compromise the lifecycle of the pump.
Why are check valves needed?
Check valves are required so that water is only able to flow in one direction, in order to prevent the water in the column above the pump and in the pressure tank from draining back into the well when the pump shuts off. This makes them an important part ...
How many check valves are needed for a submersible pump?
This makes them an important part of a submersible pump installation, and it is recommended that there should always be at least one check valve.
What happens if a pump has no check valve?
With no check valve, a leaking check valve or drilled check valve, the pump unit will start under a zero head condition, causing an uplifting or upthrust on the impeller-shaft assembly in the pump.
What happens if a pump motor is started?
If the motor is started while it is in this state, an excessive amount of force is placed across the pump-motor assembly, potentially causing impeller damage, motor or pump shaft breakage and excessive bearing wear.
What happens when you start a vacuum pump?
Upon starting the pump after the vacuum is created, water moving at a very high velocity will fill the void and strike the closed check valve and the stationary water in the pipe above it.