What are some reasons why my furnace keeps turning on and off?
When a furnace keeps turning on and off, it is usually due to short cycling. This is the term used to describe problems originating from within the heating system. If short cycling is not promptly diagnosed and corrected, it could cause permanent damage to your heating unit and higher utility bills.
Why is my furnace not kicking on?
What Would Cause a Furnace not to Kick ON?
- Thermostat issues. If your furnace isn’t responding to temperature changes, the most likely culprit is the thermostat.
- Ignition issues. If the thermostat is in good working condition, then the next thing you want to check is the ignition system.
- Gas supply issues. ...
- Electrical issues. ...
Why furnace not coming on at all?
Sometimes the reason for a furnace not turning on is because it’s simply turned off. Locate the power switch on the furnace itself, which is likely on a nearby wall, or even on a ceiling or floor joist near the unit. It will often look like a regular light switch, but it may or may not be labeled.
Why is my furnace making a clicking noise?
Reasons a furnace might make a clicking noise includes:
- Loose inducer: Oil-powered furnaces use a motor-powered fan, or inducer, to push out smoke and fumes. ...
- Worn motor bearings: The bearings in the furnace’s motor will click when they become worn. ...
- Gas valve problems: If the clicking sound doesn’t seem to have a pattern, it could indicate an issue with the gas valve. ...

Why does my furnace keep clicking?
Your furnace is most likely making a clicking noise due to your furnace's spark igniter trying to ignite the pilot light/burners. A repeated clicking indicates a failure/system malfunction. This problem is especially troublesome when you are not getting heat at some point during the very cold winter months.
How do I reset my furnace ignitor?
Resetting The Ignitor Once the power is off you can remove the burner door to reveal the ignitor. Turn this to “off” and leave it off for at least 5 minutes. After this time, turn the ignitor back to the “on” position and replace the burner door. You can then turn the power source back on and restart the furnace.
How often should a furnace click on?
three to eight times per hourOn average, furnaces should kick on and turn off anywhere from three to eight times per hour. However, if your furnace turns on and off more frequently, don't assume the furnace is short cycling just yet.
How do I know if my ignitor is bad on my furnace?
Here are a few indications that you have a faulty ignitor.No Cold Air. ... The Furnace Won't Come On. ... The Furnace Suddenly Stops Blowing. ... Starts, Then Stops, Then Starts Again. ... Tripping the Breaker More Than Once. ... I Hear the Click, But Nothing Happens. ... Flame Sensor Problems. ... Short Circuit.More items...•
Can a furnace ignitor be cleaned?
Once you have removed the sensor, rub the metal rod with fine grit sandpaper to remove grease and dirt. Then, use a clean paper towel to wipe away any remaining dust or dirt. Once you've cleaned it, replace the sensor and the screw, and your furnace should start working again.
How many times can I hit the reset button on my furnace?
Don't hit “reset” more than twice. The process pumps oil into the burner chamber, where it can accumulate if you have no ignition. Then when the furnace finally does start, it can do so explosively. So if the button won't reset, or quickly pops up again, it's time to call a professional repair service.
How do you fix a furnace that clicks?
Loud clicking sounds can be heard when inducer blowers and fan shafts are clogged by buildup or when bearings are worn out. Bearings on the main blower motor might click as the furnace runs because the shaft is rusted or dirty. Cleaning and lubricating the fan shaft will help fix the problem and prevent premature wear.
Why does my furnace click on and off?
1. Why Is My Furnace Making A Clicking Noise? If your furnace is constantly making a clicking noise then you are likely looking at a mechanical malfunction of some sort. A clicking furnace is often caused when the furnace's spark igniter tries to ignite the pilot light or burners.
How do I know if my furnace is short cycling?
A good way to tell if your furnace is short-cycling is if your heater turns on and off several times repeatedly without producing any heat. A furnace that is the right size for the home and working properly cycles approximately three to eight times per hour.
How much does it cost to have a furnace ignitor replace?
Your furnace's ignitor plays a critical part in the start-up process. As its name suggests, it ignites the gas your furnace turns to heat. The average cost to repair or replace an ignitor is $150–$300.
How long should a furnace ignitor last?
The igniter glows red and then lights the burners in the gas furnace. Over time, the igniter is continually getting red hot and then cooling, creating stress on the element. Because of this, igniters have a 3-5 year life expectancy. They will eventually crack and need to be replaced.
How much does an igniter for a furnace cost?
Igniter Cost: The igniter costs no more than $30 to $50. Check with your furnace manufacture for the model number of your furnace so you can find the right igniter for your unit. Furnaces can last for several years, and hence it is not hard to find the right replacement part.
Where is the reset button on a gas furnace?
1:192:03How to Troubleshoot and Reset a Furnace - YouTubeYouTubeStart of suggested clipEnd of suggested clipYou're gonna come to a light switch it can be located on your left side of the furnace. Or on theMoreYou're gonna come to a light switch it can be located on your left side of the furnace. Or on the right this happens to be on the right side. It's a simple pretty much a basic light switch on any home
Can hear your furnace click on but it does not fire up?
Ongoing clicking when the furnace isn't working may be a sign that gas isn't reaching the pilot light. The ignitor will keep clicking as it tries to spark a flame. This could indicate a dangerous gas leak or clogged gas valve.
What causes a gas furnace not to ignite?
Common types of natural gas issues include gas leaks, blocked gas lines, and malfunctioning gas valves. If the gas line is off, simply turn it back on. If the furnace won't ignite after doing this, call an HVAC professional to check for other potential problems.
How do you trick a flame sensor?
The process is rather simple:Shut off power and gas to the furnace.Remove the sensor.Clean away soot and corrosion with a clean emery cloth.Reinstall the flame sensor.Restart the furnace.
Why does my furnace keep clicking?
Dirty or clogged sensor: A dirty or clogged thermocouple can result in prolonged clicking coming from your furnace. The thermocouple is a sensor that detects a flame and signals the system to shut its gas valve. If the sensor is covered in dirt or grime, it won’t acknowledge the flame and signal the rest of the system accordingly. When this happens, the spark igniter will operate as if there isn’t a flame. It will continue to click while the furnace is running until it wears out.
Why does my furnace click?
Your furnace’s gas valve could shut due to a bad ignition board, poor connection between the board and the valve, or a bad valve itself . Regardless of the cause, a closed valve can cause your furnace to click endlessly in a futile attempt to light your heating system.
Why Is My Furnace Making Clicking Sounds?
Hearing a clicking noise from your furnace is not that unusual. There are various reasons why you’ll hear your furnace make clicking noises when it’s off, while it’s running or during startup, and it’s often something you don’t want to ignore.
Can a furnace leak gas?
Electrical components: Electrical furnaces won’t leak gas, but their inner workings can still malfunction and result in a clicking noise.
Why is my furnace making a clicking noise?
Most likely, your furnace is making a clicking noise and not providing heat because your furnace’s spark igniter is trying to ignite your pilot light or burners but is failing to do so. In other words, there’s an ignition system malfunction that needs to be fixed. Otherwise, your furnace won’t start. Before we get into more details, we need ...
What is click ignition?
The click is the spark caused by a spark igniter, which is used in 2 common ignition systems: Intermittent pilot ignition —Uses a spark igniter to light the pilot flame, which then ignites the burners. Direct spark ignition (DSI) —Uses a spark igniter to directly ignite the burners.
Why does my gas valve keep shutting off?
So if the gas valve is shut, the spark igniter has nothing to ignite and just keeps sparking. Some causes of a shut gas valve include: Bad ignition board. Bad connection between the board and the valve. Bad valve. All of the above are issues a furnace technician needs to fix.
Why won't my thermocouple sense the pilot flame?
However, if the thermocouple is malfunctioning or covered in soot, it won’t sense the pilot flame and shut the gas valve. The spark igniter will spark (click) for about a minute trying to ignite the flame. Pilot light/flame issues.
Why is my pilot flame not hitting the thermocouple?
The pilot flame may not be hitting the thermocouple properly due to an incorrect mixture of gas and air. Again, if the flame sensor thinks the flame isn't lit, the spark igniter sparks again and again until it gives up. No gas = no ignition.
What does the furnace start?
Just like how your car’s ignition system starts your car, the furnace’s ignition system starts (“ignites”) the furnace burners, which heat your air.
Why does the draft switch close?
The draft switch closes to prove the draft fan is working.
Why Does My Furnace Make a Clicking Noise?
If you have a gas furnace, a clicking noise can indicate a problem with the ignitor or gas valve. In the worst-case scenario, this can lead to a gas leak; that’s why calling a professional in such a situation is vitally important.
Is It Normal for a Furnace to Click?
It is normal for a gas furnace to make a ‘click’ whenever it starts off. You will hear this sound when the spark igniter lights the gas a burner.
Why is My Furnace Clicking?
It’s common for furnaces to make noises, such as the hum you hear as it operates. Pay attention to unfamiliar sounds as they could be a sign that the heating system needs a repair.
Why does my furnace fan click?
Clicking can also happen if soot or grime builds up on the fan blades. It’s best to let a professional deal with cleaning or calibrating the fan, especially if the furnace is still under warranty. Worn motor bearings: The bearings in the furnace’s motor will click when they become worn.
Why is My Furnace Blowing Cold Air?
If you notice cold air blowing from the registers in your home, here are some troubleshooting steps you may take before calling a professional for help:
What happens if a furnace drain line is clogged?
If the line becomes clogged, it can trigger a safety feature that keeps the burners from lighting.
How to know if your furnace is on auto mode?
Verify that it’s set to “Auto” instead of “On.” When the furnace is on the “On” mode, it will continuously blow air, even if it’s not heating the air.
Why does my gas valve make a clicking sound?
Gas valve problems: If the clicking sound doesn’t seem to have a pattern, it could indicate an issue with the gas valve. The fix is a home meter replacement, a repair that must be completed by a professional from your gas company, as required by law.
What happens when ductwork leaks?
Ductwork leaks: When ductwork has holes, it will send warm air into unoccupied spaces of your home , such as the attic or crawlspace. Similarly, cold air from the unoccupied spaces might enter the ductwork and blow into your home. A duct inspection and repair will remedy the problem.
Why does my furnace click?
Clicking from gas furnaces often indicates a problem with the gas valve or ignitor—and you certainly don’t want a gas leak.
What does clicking on an electric furnace mean?
You don’t have to worry about a gas leak, but clicking from an electric furnace means you need repair.
What does it mean when a gas valve ignitor clicks?
When this happens, the ignitor clicks and clicks endlessly, like someone trying to use an empty lighter. Flame sensor or thermocouple — This part senses the presence of a flame and tells the gas valve to open. If it’s faulty or dirty, it won’t send the signal and the ignitor will click.
Why does my ignition make a clicking noise?
Fan or inducer — These parts sometimes make clicking noises due to a broken fan blade.
What does it mean when a duct is clicking?
Clicking sound from ducts — Do you hear clicking in the house, away from the furnace? A duct seam may have come loose such that two pieces of metal are clicking together as air passes through. Or something stuck in the duct is rattling around rhythmically.
What is the noise of a furnace?
Radiators make knocking and hissing sounds, and even a small ductless system will hum a little. Furnaces will make a low hum or rumble while operating normally. Clicking sounds are one noise you don’t want to hear.
Can a furnace keep running?
Whether it’s a dangerous gas leak situation or just a faulty furnace, you should never let your furnace keep running if it sounds like it’s acting up. One bad part can make another part break down, or cause the furnace to run inefficiently, exacerbating the problem.
Why won't my oven ignite?
The pilot flame may fail to ignite the oven burner if it’s poorly adjusted or if the tubes running from the pilot flame to the burners are blocked.
How many times does a stove igniter click?
A normal igniter clicks up to three times before it sparks and lights your stove. Sometimes, however, the igniter will click continuously—even after the stove is lit. The following are some of the more possible causes and solutions to the problem.
What happens if the burner element of an oven is broken?
If the burner element of an oven is broken, it might be impossible for the oven to reach the set temperature.
Why does my gas range keep heating up?
Modern gas ranges have thermostats and thermal sensors built into them to control their oven temperature. If the thermostat or thermal sensor is faulty or calibrated wrongly, it may stop your oven from heating up. Some thermal sensors also have thermal fuses. The thermal fuse may blow up if the oven overheats.
How to check continuity of stove?
Use a multimeter on each of the stove switches. A spark ignition switch that shows continuity is faulty and should be replaced.
What is a spark ignition system?
Spark ignition systems are modified pilot ignition systems. Instead of relying on a pilot flame to ignite the cooking gas, a spark is used to light the pilot gas. The spark module powers the spark electrode for each surface burner. Damaged spark modules may begin to spark continuously on their own. If the spark modules of your stove are damaged, ...
What is the problem with the power supply to the igniter?
Problem with the power supply to the igniter. An ignitor that doesn’t get hot enough to open up the valve. No gas flowing through the valve. An ignitor that fails to get hot enough to set the oven gas aflame.