Temperature & Pressure Relief valves may open, leak, or drip for a variety of reasons including:
- Boiler limit control problems: On a heating boiler, the boiler temperatures are excessive, possibly due to an improperly set limit control, lack of contact between the limit switch sensor and its mounting well, or a defective control. ...
- Closed hot water systems: Periodic discharge of the temperature and pressure relief valve may be due to thermal expansion in a closed water supply system. ...
What to do if a pressure relief valve is leaking?
You can take the following DIY steps to seal the leaks:
- Switch off the electric breaker ( if you’re using an electric pressure valve). ...
- Seal off the cut-off valve that takes cold water to the water heater.
- Drain some water out of the tank by opening the valve at the lower end and the pressure relief valve. ...
- Remove (or cut off if it’s glued) the overflow pipe from the pressure relief valve.
Why is my water heater pressure relief valve leaking?
- You have a closed water system, and the water heater is causing the pressure to rise in the system. ...
- If you are on a domestic water well, the pressure sensor on your pump and pressure tank may need to be adjusted. ...
- Too much pressure from a municipal water system is not usually a problem but can occur. ...
What would cause a temperature relief valve to leak?
a RELIEF VALVE LEAK DUE TO EXPANSION TANK failure or defect. Water hammer: The building plumbing system suffers from water hammer. Water hammer in buildings causes surging in the water piping that in turn can cause leaks at pressure/temperature or other pressure relief valves, particularly at the pressure safety valve found at water pressure tanks.
How to stop a leaking water pressure relief valve?
Water Line Pressure Relief Valve Leaking | Leaking Pressure Relief Valve
- Main water line pressure relief valve leaking even after the replacement. ...
- You should be alert if the water pressure of your main supply is too high. ...
- Get that pressure regulator installed if you haven’t still, let me tell you why. ...
- The expansion tank will give your water that second chance it deserves. ...
How to remove TPR valve?
What is a TPR valve?
What to do if relief valve continues to leak?
What is discharge to the floor?
Why does my water heater have a ticking time bomb?
What does it mean when your water heater is under stress?
What size valve should be discharged to the air gap?
See 2 more

What to do if pressure relief valve is leaking?
Leaking Relief ValveTurn off the water heater breaker.Shut off your water.Empty the water heater by draining the bottom and water inside your home.Remove the TPR valve and discharge tube by unscrewing with a wrench.Replace with a new TPR valve and discharge tube.More items...•
What causes a TPR valve to leak?
Pressure relief and safety relief valves will leak if the valve isn't fully closed. This is a common problem in industrial settings where environments are often dusty or dirty. If there is any debris in the valve, it can obstruct the valve from fully closing, causing it to leak.
Is it normal for relief valve to drip?
It's quite common for water to be dripping from the temperature-pressure relief valve, which is designed to release water when it senses too much pressure.
Should my pressure relief valve is leaking?
A slight leak may occur if your water heater's pressure relief valve has not been opened for a while, say a few years. While this leak is normal and may not be an indicator of a problem with the water heater system, you may need to replace the valve if the leak becomes more serious.
How often should a pressure relief valve leak?
In general, we recommend the following schedule: Testing every 12 months. Repair every three to five years.
What causes too much pressure in hot water heater?
Why is My Water Heater Building Up Too Much Pressure? If your water heater is building up too much pressure there's likely three reasons. Either the temperature is set too high, there's a malfunction, or the water heater doesn't have an expansion tank.
How do I know if my water heater relief valve is bad?
Excessive noise: If your hot water heater is rattling or emitting a high-pitched whistling noise, it's likely the sound of steam trying to escape the tank, which is a sign of far too much pressure pressing against the inner walls. This means the relief valve isn't doing its job and may need replacing.
How much does it cost to replace a pressure relief valve on a hot water heater?
Pressure Relief Valve – $20 to $200 If you notice that the valve is consistently leaking, it may mean that the tank's pressure is too high, or you might simply have a faulty/clogged valve. The cost of a new pressure relief valve is about $20, and repairs may total to $200.
Can a bad expansion tank cause a pressure relief valve to leak?
A leaking water heater temperature and pressure relief valve is a sign that it is defective, you have a closed-loop system (with a check valve or pressure reducing valve), or the water pressure in your house is too high. A waterlogged thermal expansion tank can also cause the problem.
Why is my hot water overflow pipe leaking?
When an overflow pipe is dripping or running with water, one of the most common causes is a problem with a float valve. Float valves are found in toilet cisterns, cold water tanks and central heating feed and expansion tanks.
How do you test a TPR valve on a water heater?
To test the TPR valve, simply lift it up and down several times. This should lift the attached brass stem and hot water should get flow out of the drainpipe. You should hear a gurgling sound as the valve allows some water to be released into the drain tube.
How much does it cost to replace a pressure relief valve on a hot water heater?
Pressure Relief Valve – $20 to $200 If you notice that the valve is consistently leaking, it may mean that the tank's pressure is too high, or you might simply have a faulty/clogged valve. The cost of a new pressure relief valve is about $20, and repairs may total to $200.
Why is my pressure valve leaking?
If the gauge shows the pressure is at 150 psi or greater, excessive water pressure is probably causing your pressure valve to leak. But if the leak is active while the pressure is normal, the water pressure in your plumbing system probably isn’t causing it. Excess pressure is usually caused by a closed plumbing system.
How much does it cost to replace a TPR valve?
Fixing the valve is technically possible, but replacing it is honestly the easiest and safest option. Most replacement TPR valves cost approximately $30 or less, and the replacement process is pretty straightforward. Here’s a step-by-step walkthrough:
Why do water heaters have pressure valves?
This valve exists to give water and steam the chance to escape when the temperature or pressure gets too high inside the water heater tank. Although the name contains both “temperature” and “pressure”, most valves are almost exclusively used for pressure relief. This is because the temperature of your water needs to rise to a ridiculously high ...
Why does my water heater explode?
This is because the temperature of your water needs to rise to a ridiculously high level to set off the valve . If this valve didn’t exist, your water heater would be a ticking time bomb sitting in your home. If excess pressure rose to an unsustainable level , the water heater could explode.
Why does my water heater have a lot of pressure?
Excess pressure is usually caused by a closed plumbing system. The water heater does its job and heats the water, which causes upward expansion of the water and an increase in pressure . If the system is closed, the water won’t have anywhere to go, and the T&P valve opens to relieve the pressure.
What is a pressure relief valve?
The temperature & pressure relief valve is a safety feature on an electric or gas tank water heaters that will open to discharge hot water and reduce pressure inside the tank. There are numerous possible reasons your water heater’s pressure relief valve leaks.
What is a T&P valve?
A leaking temperature and pressure (T &P) relief valve on your water heater can be a perplexing problem. Understanding why your valve is leaking ‒ and how to fix it ‒ are both important pieces of information for any homeowner to have.
What does it mean when a T&P valve starts leaking?
If a recently replaced T&P relief valve starts leaking again, it probably means that the relief valve is only doing it’s job; it relieving excess pressure in the water heater. When this happens, the fix gets a little bit more involved. I’ll explain.
What happens when a check valve is installed?
When a check valve is installed, it becomes a closed plumbing system. Because it's closed the pressure in the system increases, as the heater heats the water. An expansion tank that is properly charged (charged to the "normal" water pressure) will "absorb" the pressure increase, keeping the system at a steady pressure.
Does a water heater have a T&P valve?
The water wouldn’t have anywhere to go. As the water heater heats the water, it expands, which builds up pressure in what is now essentially a closed system. When the pressure builds up enough, the T&P relief valve on the water heater just does it’s job and relieves the excess pressure by leaking a little water.
Did the service man replace the TPR valve?
The service man came and replaced the TPR as a shot gun approach but I checked it immediately afterwards and the same dripping from the TPR valve occurred.
Why Water Heater Pressure Relief Valves Leak
There are some common reasons why your water heater pressure relief valve might leak. One is excessively high temperatures in the water tank. Either a gas burner or electricity heats the water inside the tank, and the pressure relief valve is a safety mechanism to make sure the tank doesn’t overheat.
Your Water Heater Pressure Relief Valve Is Leaking. Now What?
What are some of the signs that your water heater pressure relief valve is leaking?
What to Do When You Find a Leak
Assess the leak. Find out whether or not the leak is from normal pressure release or a bad valve. Replace the valve if needed.
Things to Consider
If the leakage is severe, immediately turn off the water heater. If your water heater uses gas, locate the gas line, which is usually near the water heater. Turn the gas valve clockwise until the gas is entirely off.
When to Call a Pro
If the water heater pressure relief valve is often open and leaking, there could be an issue with your water heater. If your water heater is constantly at a high temperature, there is a high-pressure buildup.
How much does it cost to replace a TPR valve?
As I mentioned in my original post about leaking TPR valves, an easy troubleshooting step is to replace the leaking valve. TPR valves cost less than $15 and they're fairly easy to replace. If you're not sure how to go about doing this, hire a plumber. If you're trying to do this on the cheap because you can't afford a plumber, search YouTube for videos of "relief valve replacement". You'll find a ton of 'em there.
What temperature should I use for a TPR valve?
For the record, a safe temperature for water coming out of faucets is 120 degrees. Temperatures in the 150 degree range are downright dangerous and in need of attention, but still wouldn't explain a leaking TPR valve. Temperatures really need to approach boiling to set off a TPR valve. This is extremely unlikely, but I suppose it is a possibility.
What is the pressure relief valve on a water heater?
A Quick Primer. All water heaters are equipped with a temperate and pressure relief valve. This valve will allow water or steam to escape from the water heater if the temperature or pressure gets too high; these valves are set to open when the pressure reaches 150 psi, or when the temperature reaches 210 degrees fahrenheit.
How to fix a water pressure over 80?
The easiest way to do this is to get a gauge with a garden hose thread, connect it to an outside garden hose faucet (sillcock), and open up the faucet. You should expect the pressure to be somewhere in the 40 – 80 psi range, with no other water running. If the pressure is over 80 psi, it should be corrected. The solution is to have a pressure regulator installed. Get a plumber to do that.
Why is my water heater leaking?
If it's not defective, it's leaking because the temperature was too high or the pressure was too high. In other words, a leaking TPR valve indicates one of these things: a defective valve, excessive pressure, or excessive temperature. 1. Verify the right valve is installed. As I mentioned earlier, the TPR valve on a water heater is set to go ...
What happens if the pressure in the plumbing system exceeds 150 psi?
If the pressure in the plumbing system exceeds 150 psi, the TPR valve will leak. Getting to the bottom of this issue should be quite simple and straightforward. Buy a pressure gauge with an extra indicator to show surges, and connect it to the plumbing system. It doesn't matter if it's connected to a hot or cold water pipe, because both will be at the same pressure.
What happens if you accidentally install a pressure relief valve on a water heater?
If a pressure relief valve for a boiler is accidentally installed on a water heater, it will leak like crazy from the start. These valves may look identical, but they're set to go off at 30 psi, not 150 psi.
Why is my TPR valve leaking?
If a TPR valve leaks, either it’s defective or it’s not. If it’s not defective, it’s leaking because the temperature was too high or the pressure was too high. In other words, a leaking TPR valve indicates one of these things: a defective valve, excessive pressure, or excessive temperature. 1.
How much does it cost to replace a TPR valve?
As I mentioned in my original post about leaking TPR valves, an easy troubleshooting step is to replace the leaking valve. TPR valves cost less than $15 and they’re fairly easy to replace. If you’re not sure how to go about doing this, hire a plumber. If you’re trying to do this on the cheap because you can’t afford a plumber, search YouTube for videos of “relief valve replacement”. You’ll find a ton of ’em there.
What happens if the pressure in the plumbing system exceeds 150 psi?
If the pressure in the plumbing system exceeds 150 psi, the TPR valve will leak. Getting to the bottom of this issue should be quite simple and straightforward. Buy a pressure gauge with an extra indicator to show surges, and connect it to the plumbing system. It doesn’t matter if it’s connected to a hot or cold water pipe, because both will be at the same pressure.
What is the pressure relief valve on a water heater?
This valve will allow water or steam to escape from the water heater if the temperature or pressure gets too high; these valves are set to open when the pressure reaches 150 psi, or when the temperature reaches 210 degrees fahrenheit.
How to fix a water pressure over 80?
The easiest way to do this is to get a gauge with a garden hose thread, connect it to an outside garden hose faucet (sillcock), and open up the faucet. You should expect the pressure to be somewhere in the 40 – 80 psi range, with no other water running. If the pressure is over 80 psi, it should be corrected. The solution is to have a pressure regulator installed. Get a plumber to do that.
What happens if you accidentally install a pressure relief valve on a water heater?
If a pressure relief valve for a boiler is accidentally installed on a water heater, it will leak like crazy from the start. These valves may look identical, but they’re set to go off at 30 psi, not 150 psi.
Do you need a tempering valve between a water heater and a faucet?
Make sure there are no tempering valves installed between the water heater and the faucet; whole-house tempering valves are typically installed at the water heater, and look like the type shown in the photo below, which I used in my blog post about safe water temperatures.
Why does water come out of the relief valve?
Reasons for water discharging from the relief valve. When you see water coming out from the water heater release valve, there are two most likely causes. The relief valve is working the way it’s intended, and water drained to reduce the pressure inside the tank. There’s a problem with the valve, such as a faulty seal, ...
Why is my water heater leaking?
If the relief valve is needed frequently, that means there’s an issue with your water heater that is causing unsafe temperatures or pressure. On the other hand, if the relief valve is stuck ...
What does the relief valve do?
The relief valve is an important safety feature on the water heater. If the water inside the unit gets too hot (usually above 210 degrees) or pressure builds up too high (above 150 psi), the water heater can become damaged or even explore.
What to do if water pressure is unsafe?
If at any point the temperature or pressure reaches an unsafe level, the water heater triggers the relief valve to open and release water out of the tank until the temperature and pressure return to normal.
Is it bad to have water on the floor of a water heater?
It’s never a good sign when you find water on the floor around your water heater. But before you panic, it’s important to figure out where it’s coming from.
What causes a TP valve to leak?
Leaks into the heating boiler or water heater: leaks into a heating of water from a higher pressure building source can cause recurrent TP valve leaking. For example, if the tankless coil in a heating boiler is leaky, higher pressure water inside the tankless coil may leak out of the coil into the heating boiler.
What causes a pressure relief valve to leak?
Pressure Relief Valve Defects, or Pressure/Temperature Relief Valve Defects that cause leaks#N#Dirt or debris are preventing proper closure of the relief valve valve#N#A deteriorated gasket inside the relief valve or corrosion on the valve seat can cause leaking at the valve; we find this mess occurring when someone lifts the "test lever" on a older P/T valve that has not been tested or operated for some time. A brittle piece of gasket can be spit out of the valve and it will then keep leaking.#N#The wrong T&P valve has been installed or set to too-low a working pressure. (Proper set pressure is at least 20-30 psi above the working pressure of the equipment to be protected). 1 Dirt or debris are preventing proper closure of the relief valve valve 2 A deteriorated gasket inside the relief valve or corrosion on the valve seat can cause leaking at the valve; we find this mess occurring when someone lifts the "test lever" on a older P/T valve that has not been tested or operated for some time. A brittle piece of gasket can be spit out of the valve and it will then keep leaking. 3 The wrong T&P valve has been installed or set to too-low a working pressure. (Proper set pressure is at least 20-30 psi above the working pressure of the equipment to be protected).
Why is my T&P tank overheating?
That's because an overheated condition exists right at the sensor point of the T&P valve - most of the overheated water is "congested" at the top of the tank. This problem can be caused by undersized circulation piping between the sidearm heater and the water tank.
Why must the TP valve point down?
Technical note: why must the TP Valve point "down"? Take a look at the photo above. If a relief valve is dripping the deposit of minerals inside the valve will accumulate still more rapidly if the valve points to the side or upwards. The result is a clogged valve as we explain above - a dangerous situation that risks an explosion.
What happens if a relief valve is clogged?
If a relief valve becomes clogged and won't open when it should, the result could be a very serious explosion called a BLEVE EXPLOSION.
What causes water hammer in a building?
Water hammer: The building plumbing system suffers from water hammer. Water hammer in buildings causes surging in the water piping that in turn can cause leaks at pressure/temperature or other pressure relief valves, particularly at the pressure safety valve found at water pressure tanks. See WATER HAMMER NOISE DIAGNOSE & CURE.
How far above the floor should a water heater discharge valve be?
Install the valve into an opening provided and marked for this purpose in the water heater, and orient it or provide tubing so that any discharge from the valve exits only within 6 inches above, or at any distance below, the structural floor, and does not contact any live electrical part. The discharge opening must not be blocked or reduced in size under any circumstance. [1] [2]
How to remove TPR valve?
Remove the TPR valve and discharge tube by unscrewing with a wrench.
What is a TPR valve?
What Is The Temperature Pressure Relief Valve (TPR) The TPR valve, also called, a pressure relief valve is a specialized valve at your water heater. This valve is typically on the top or side of your water heater. The valve functions by releasing water if your water heater becomes too pressurized. Since heated water expands, ...
What to do if relief valve continues to leak?
However, if you find the relief valve to continue to leak even after replacement, you should contact a plumber for assistance. A licensed plumber will be able to evaluate your system and decide on installing an expansion tank or other solutions. If you have additional questions, be sure to drop a comment below!
What is discharge to the floor?
Discharge to the floor, to the pan serving the water heater or storage tank, to a waste receptor or to the outdoors. Discharge in a manner that does not cause personal injury or structural damage. Discharge to a termination point that is readily observable by the building occupants. Not be trapped.
Why does my water heater have a ticking time bomb?
The valve functions by releasing water if your water heater becomes too pressurized. Since heated water expands , the water heater can become a ticking time bomb if we were to continually build pressure in your water heater.
What does it mean when your water heater is under stress?
This means the pressure is building up too much in the water heater and your water piping could be under stress.
What size valve should be discharged to the air gap?
Not be smaller than the diameter of the outlet of the valve served and shall discharge full size to the air gap.