why is suction line cold

by Prof. Nedra Oberbrunner Published 3 years ago Updated 2 years ago
image

Refrigerants have two copper lines that connect the indoor evaporator coil and the outdoor heat pump. The suction line is the larger tube that has insulation. It carries cool gas under low pressure from the indoor evaporator to the outdoor compressor.Jun 6, 2022

Full Answer

Should suction lines be cold?

The Copper Pipe (Suction Line) should be sweating and cold to the touch during a hot day. If it is not cold, your compressor could be off (bad capacitor/ hard start kit) or low on Refrigerant.

Why does the suction line get cold?

The heat causes the refrigerant to boil, which changes it to a low pressure vapor. When the refrigerant reaches the end of the evaporator, it's a cool vapor. The cool vapor travels down the suction line, and back to the compressor where the refrigeration cycle can start again.

How do you fix a freezing suction line?

Clogged Air Filters The first step to troubleshooting a frozen suction line is to check your air filter. You should be changing your AC air filters monthly in peak season. If not, they become clogged and prevent proper airflow. In turn, it freezes the coils.

What does ice on the suction line mean?

Frost on a suction line may indicate a flooded evaporator. A flooding evaporator is being fed more refrigerant than it can boil off and this may slug the compressor. Liquid leaving the evaporator may be indicated by frost on the suction line or compressor.

What temp should my suction line be?

The suction temperature should be above 35°F and below 65°F entering the compressor and the discharge line temperature should be below 220°F and above 150°F (typically) on a properly functioning package unit.

Why is my low side line freezing up?

Some common reasons that cause your AC lines to freeze are: Refrigerant leaks from evaporator coils. Accumulation of dirt over the coils. Blocked AC vents. Clogged air filters.

What is the most common reason that you would find ice on the suction side of a condensing unit?

Refrigerant charge level: Improper refrigerant charge (too low a charge of refrigerant in the A/C system can, for a while, lead to too-low temperatures in the coil which will then cause frost or ice build-up on the suction line.

What causes icing back to the compressor?

All in all, a bit of frost on your compressor is nothing to fret over. It just means that the air around your compressor is warm and that your compressor is working hard to keep things cool inside your system. The frost is not a sign of a leak, and won't cause any damage to the unit by itself.

What are the symptoms of a bad Txv valve?

Bad TXV valve symptoms There is frost on the evaporator. Your unit is blowing warm air. The AC compressor is running constantly.

Will low refrigerant cause freezing?

Low Refrigerant Improper refrigerant fluid levels can also cause an HVAC unit to freeze up. When the refrigerant is low, the coils will be too cold, causing them to freeze.

Why does vapor line freeze?

If the filter gets dirty, it blocks airflow to the evaporator coil. Without airflow, heat doesn't get to the evaporator coil, and the refrigerant doesn't boil. As a result, the pressure and the temperature will drop, causing the system to freeze.

What causes expansion valve to ice up?

Moisture in the System If the drier becomes saturated with moisture, it releases it at the hottest times of the day. This moisture freezes in the expansion valve and deprives the evaporator of refrigerant.

Why does vapor line freeze?

If the filter gets dirty, it blocks airflow to the evaporator coil. Without airflow, heat doesn't get to the evaporator coil, and the refrigerant doesn't boil. As a result, the pressure and the temperature will drop, causing the system to freeze.

What temperature does refrigerant freeze?

32 degreesA refrigerant is basically a liquid or a gas with a very low boiling point. Where water normally boils at 212 degrees Fahrenheit (and freezes at 32 degrees), a refrigerant like R-134a boils at 15 degrees below zero (and freezes at -154).

Where is the suction line on a refrigerator?

Locating the Refrigerator Compressor The valve between the condenser and the compressor is the outgoing valve. Once you know which valve is the outgoing valve, locate the other valve on the compressor. This is the suction valve, which should be attached to the evaporator.

What is the warmest suction line?

The warmest a suction line can be is whatever the return air temperature that is blowing across the evaporator is . I don't think it can physically be any warmer than that (unless we're talking about a heat pump when the suction line turns into the discharge line).

Why is my refrigerant line warm?

As refrigerant pressure begins to drop, the system doesn't have enough capacity to handle the heat in the house. This will cause the line to be warmish...

What happens if a refrigerant is low?

If a system is low of refrigerant then you would have zero subcooling, which would tend to make the liquid line WARMER than normal. At the same time the lower low side pressure would make the temperature of the refrigerant in the beginning part of the evaporator colder than normal, which could cause it to freeze up starting near the expansion valve and eventually the entire coil and suction line back to the compressor.

Does cold suction line leave the inside of AC unit?

This is the misconception that most all my customers have. To the novice: The truth is that the cold suction line has already left the inside ac unit.

Is HVAC talk a DIY site?

Welcome to HVAC-Talk. com, a non-DIY site and the ultimate Source for HVAC Information & Knowledge Sharing for the industry professional! Here you can join over 150,000 HVAC Professionals & enthusiasts from around the world discussing all things related to HVAC/R. You are currently viewing as a NON-REGISTERED guest which gives you limited access to view discussions

Can a coil pick up heat from the attic?

Also, if the coil is in the attic it can pick up a lot of heat from there.

Can a suction line be frozen?

The liquid line is always at or above ambient temperature. It cannot be frozen unless there is a restriction such as a plugged dryer etc. The large suction line can be colder or warmer depending on the amount of refrigerant and the temp in the house.

Does liquid line get colder outside?

The liquid line gets less colder as you go outside.

Does the A/C cool the house?

The A/C still cools the house, but the cold liquid line worries me. 1. Is it normal for the liquid line to be cold next to the air handler. The liquid line gets less colder as you go outside. ... replaced on the Goodman under warranty and checked the bill and they never replaced the dryer.

Is there a problem with liquid line?

If the liquid line is colder than the ambient temperature, and/or condensating or frosting, then there is definitely an issue.

What happens when the refrigerant is low?

When the refrigerant in the system is low, the pressure; and therefore temperature, of the refrigerant will also be lower. In a normal system, the temperature of the refrigerant at the beginning of the evaporator will be right around the freezing temperature of water (32°F). As the indoor air moves over the cool coils, ...

Why does my HVAC coil freeze?

Once the coils drop below the freezing point, moisture in the return air that's passing over the coils doesn't just condense and run out the condensate drain (think of a cold drinking glass on a hot humid day, your coils look like that normally). Instead, that condensation freezes until it's a solid block of ice and no air can pass through. This same problem can happen if you run your HVAC when the outside temperature is too low, so much heat gets removed by the outdoor coils, that when the refrigerant runs through the evaporator is gets below the freezing point. This is why it's very important to not oversize an HVAC for your home, it will cool the air too quickly and result in freezing, and it will run for very short periods of time but not remove enough moisture due to those short run times, leaving you very humid in the summer.

What is HVAC system?

The HVAC consists of a closed refrigerant loop. At the outside of your home will be a compressor and coils. The compressor compresses the refrigerant and the process of compressing it forces the refrigerant to give off excess heat which is exhausted out the coils. Inside of your home is an evaporator unit with coils.

How does HVAC work?

The HVAC consists of a closed refrigerant loop. At the outside of your home will be a compressor and coils. The compressor compresses the refrigerant and the process of compressing it forces the refrigerant to give off excess heat which is exhausted out the coils. Inside of your home is an evaporator unit with coils. The refrigerant passes through a narrow opening at which point it expands on the other side as a gas (think of a spray can). The process of converting to a gas absorbs heat from the coils (which have the return air passing over them on their way into the ducts).

How does a compressor affect the temperature of a refrigerant?

In a normal system, The compressor compresses the refrigerant vapor. This causes the vapor to be both high temperature, and high pressure. The hot vapor moves through the condenser coils, where some of the heat is transferred into the outside air. When the vapor finally comes out of the condenser, it's a hot liquid. The hot liquid moves through the liquid line, into the building towards the evaporator coils. Just before the hot liquid refrigerant reaches the evaporator, it's forced through a metering device. The actual device used depends on the system, but capillary tubes are common.

How does a compressor work?

In a normal system, The compressor compresses the refrigerant vapor. This causes the vapor to be both high temperature, and high pressure. The hot vapor moves through the condenser coils, where some of the heat is transferred into the outside air. When the vapor finally comes out of the condenser, it's a hot liquid. The hot liquid moves through the liquid line, into the building towards the evaporator coils. Just before the hot liquid refrigerant reaches the evaporator, it's forced through a metering device. The actual device used depends on the system, but capillary tubes are common.

Why does a refrigerant coil freeze?

When the refrigerant is low, the temperature of the refrigerant at the beginning of the evaporator coils will be colder than the freezing point of water (less than 32°F). Because the coils are so cold, the condensation that forms on the coils will freeze. As ice builds up on the coils, it restricts the air flow through the coils. Because of the restriction, the refrigerant can't absorb as much heat from the the indoor air moving over the coils. This causes the refrigerant to boil later in the evaporator, which causes ice to form further along the coils. This situation continues to progress, until the whole evaporator is a block of ice. Once that happens, the refrigerant will start to boil in the suction line. This cause the temperature of the suction line to drop, and just like in the evaporator, cause the condensation to freeze.

image

1.Why Is My AC Suction Line Frozen - Innovative Air Pros

Url:https://innovativeairpros.com/why-is-my-ac-suction-line-frozen/

29 hours ago Why is the suction line cold? Over charged, or improper adjustment of the metering device causes the suction line to freeze up. Both are bad news for the compressor as well as …

2.why the suction line is warm or hot when the refrigerant …

Url:https://hvac-talk.com/vbb/threads/2195948-why-the-suction-line-is-warm-or-hot-when-the-refrigerant-is-low

22 hours ago Why is the suction line cold? Because of the restriction, the refrigerant can’t absorb as much heat from the the indoor air moving over the coils. This cause the temperature of the suction line …

3.Liquid line of outdoor AC unit is cold but the suction line …

Url:https://diy.stackexchange.com/questions/136678/liquid-line-of-outdoor-ac-unit-is-cold-but-the-suction-line-is-at-room-temperatu

2 hours ago  · Why is the suction line cold? The Copper Pipe (Suction Line) should be sweating and cold to the touch during a hot day. If it is not cold, your compressor could be off (bad …

4.Suction line not cold - DoItYourself.com Community Forums

Url:https://www.doityourself.com/forum/air-conditioning-cooling-systems/218952-suction-line-not-cold.html

32 hours ago  · If your AC suction line is frozen, check your return vents and clean any that are blocked. Fan or Blower Not Working. Your blowers and fans work together to pull warm air …

5.Liquid line is cold to the touch - HVAC-Talk: Heating, Air ...

Url:https://hvac-talk.com/vbb/threads/1633791-Liquid-line-is-cold-to-the-touch

2 hours ago  · AND THEN, because there is no freon getting into the suction line, the compressor is essentially making a vacuum on the suction line, which will make a hot. That's why when the …

6.Why do the evaporator and suction lines freeze when …

Url:https://diy.stackexchange.com/questions/48450/why-do-the-evaporator-and-suction-lines-freeze-when-there-is-low-refrigerant

13 hours ago  · So I checked while the ac is ON, the liquid (Smaller Diameter) line is very cold and sweating but the suction (Larger Diameter) line is neither too hot nor too cold its of normal …

A B C D E F G H I J K L M N O P Q R S T U V W X Y Z 1 2 3 4 5 6 7 8 9