How to Program PGM Outputs on a DSC Alarm

  1. Enter installer programming mode by typing in "*8" and then your installer's code.
  2. Type in "009" on the keypad to enter the PGM output option programming mode.
  3. Enter the two-digit code of the event that you would like to trigger the PGM1 output first, and then enter the two-digit code of the event ...
  4. Push the "#" key and then type "501" on your keypad to change PGM1's attributes. Typing "502" instead of "501" will let you change PGM2's ...
  5. Push the number of the attribute you would like to change according to the output option you chose. Pushing the number will change the ...

Full Answer

What is a PGM siren?

How to enter installer programming mode?

What does 00 05 do?

About this website

What are PGM outputs?

So a PGM is a programmable negative trigger output. What does this mean? You can think of a PGM as an on/off switch like a light switch. It will be connected to something to provide power that can be turned on or off. The system will flip the switch based on what PGM type you program it for.

How do you program zones on a DSC panel?

To program your zone definitions, you must: Enter Programming by pressing " * 8 + Installer Code " Enter Section 001 (Section 001 is used for Zones 1 - 16 only... If you have more than 16 zones, you will use 001 for the first 16 zones, then you will use section 002 for zones 17-32)

How do I program duress code on DSC 1616?

How Do I Program a Duress Code to my DSC Impassa?Enter attribute programming. At the DSC Impassa, enter the command [*] + [5] + [Master Code] + [9]. ... Assign the attribute. Once the correct user is displayed, press [*]. ... Exit user programming.

How do I reset my DSC control panel?

To reset the detectors, press and hold the Reset key for two seconds or press *72.

How do you program zone labels on a DSC keypad?

Press [*] and use the [<][>] keys to scroll to Zone Labels and press [*] again. The first zone is displayed. Alternatively, enter, [000][001]. Use the [<][>] keys to scroll to the zone label to be programmed and press [*] or enter the zone number (e.g., 001, for zone label 1).

How do I know what zones My DSC alarm?

To check which zones are open, simply press one of the arrow buttons on the keypad. This will scroll through all open zones. You can now investigate which zones are open, and correct any issue. A system which has no open zones will have a green ready light.

What is master code for DSC alarm?

1234The default master code is 1234. The master code is automatically assigned to user number 40. The master code is the first user code that comes programmed on the panel and it cannot be deleted, but it can and should be changed. The master code allows you to do quite a few things on the alarm system.

How do you clear the yellow light on a DSC alarm?

Press the '7' key and you will receive a number corresponding to the affected zone. The indicated zone is reading a low battery condition and needs a replacement battery. Replace the battery in the contact and the condition will clear.

Where can I find DSC master code?

0:351:59How to Find Master Code in DSC Keypad - YouTubeYouTubeStart of suggested clipEnd of suggested clipSo to reach the Installer menu type star then 8 then your installer password. Now type 0 0 7. If youMoreSo to reach the Installer menu type star then 8 then your installer password. Now type 0 0 7. If you have the greatest model of keypad. Your master code will show up right there.

Where is the reset button on a DSC alarm?

This button is usually located on the bottom right side of the keypad. Hold it down for at least 2 seconds to disengage the alarm. You will notice the lights on the alarm change from red to green to signal that the alarm has been reset.

How do you clear the memory on a DSC alarm system?

To clear the memory, arm and disarm the system. Certain sensors (such as smoke detectors and glass break detectors) have to be reset after an alarm. To reset detectors, press and hold the RESET key () for 2 seconds.

How do I reset the master code on my DSC alarm?

0:081:07How to change master code on a DSC security system. - YouTubeYouTubeStart of suggested clipEnd of suggested clipSo hit star five the current master code which is four three two one and then hit user forty. ThenMoreSo hit star five the current master code which is four three two one and then hit user forty. Then change it to one two three four or whatever codes you want to change it to and then hit pound.

How do you program a zone on a DSC 1832?

How do I program a wireless zone on the DSC 1616, 1832, and 1864 systems?Enter section 898. ... You will now trip the first wireless device that you want to add. ... Check that the ESN on the device and the keypad match and then press *.You will now need to enter a zone number.Then the system will ask for a zone type.More items...

How do I rename a zone on my DSC alarm?

0:001:04How to Name Zone Label On DSC Keypad - YouTubeYouTubeStart of suggested clipEnd of suggested clipHit the label programming. Then the zones button then in the zone you want to label. And name it asMoreHit the label programming. Then the zones button then in the zone you want to label. And name it as you wish in that.

How do I delete a zone on DSC?

0:002:41How to Delete a Zone on DSC Power Series Alarm System - YouTubeYouTubeStart of suggested clipEnd of suggested clipIf you want to permanently deactivate a zone on your dsc power series keypad. Well you can do it byMoreIf you want to permanently deactivate a zone on your dsc power series keypad. Well you can do it by going in the installer menu which is the star.

How do you delete a zone on DSC Impassa?

0:000:54How to Delete Sensors on your DSC Impassa Security System - YouTubeYouTubeStart of suggested clipEnd of suggested clipSo the first thing we need to do is go back into programming to delete a sensor. So star 8 5 5 5 5.MoreSo the first thing we need to do is go back into programming to delete a sensor. So star 8 5 5 5 5. We're going to go under field 8 0 4.

DSC PGM output voltage - DoItYourself.com Community Forums

With normal programming, the PGM terminals are a switch to ground. The positive voltage comes from the Aux power on the panel. You can "invert" the output on the PGMs and have them put out +12vdc, but their current limit is pretty small in that configuration.

DSC - Programming Worksheet

About Us. DSC (Digital Security Controls) is a world leader in electronic security. Since the company’s genesis, the experts at DSC have been leading the way.

How do I program for a 4-wire smoke detector on a DSC 1616, 1832, or 1

What type of smoke detectors are used with PGM?

The PGM type that will need to be used with 4-wire smoke detectors is 03 for sensor reset. Another common use is to use PGM's to turn on additional sirens or strobes. Generally the PGM will not be used to directly power the sirens or strobes in this case. Instead the PGM will be connected to a relay. The relay will be connected into a circuit ...

What is a PGM switch?

You can think of a PGM as an on/off switch like a light switch. It will be connected to something to provide power that can be turned on or off. The system will flip the switch based on what PGM type you program it for. It is the negative side of the direct current circuit. The other side will generally be on the positive auxiliary power terminal.

What is a PGM fire zone?

With 2-wire smoke detectors, the PGM becomes the fire zone for triggering an alarm as well as the resettable power circuit for the devices. 2-wire smoke detectors must be used with PGM 2 on the main board to function. And PGM 2 must be programmed as PGM type 04.

What is a PGM?

PGM definitions allow for numerous ways that the PGM will function. They can follow the bell output, follow zones, follow keypad chimes, 2-wire smoke zone, resettable power, et cetera. For a full list of PGM definitions check the full installation manual.

How many PGM outputs does a PC1864 have?

The PC1864 will have 4 PGM outputs. PGM's 1, 3, and 4 all are limited to 50mA each. PGM 2 is limited to 300mA. There are 2 modules available that can expand your PGM capabilities: PC5204 and PC5208. A PGM can be used for countless applications including custom integrations with things like lights or garage doors.

Why should a relay be connected in the normally open state?

The relay should be connected in the normally open state so that the power circuit is not closed until the relay flips. The PGM would then trigger the relay to flip to the closed state when an alarm goes off which in turn causes the power circuit to be completed.

Do smoke detectors need to be reset?

Smoke detectors are a latching alarm. This means that they will stay in the alarm state until their power is shut off. So if you ever get a smoke alarm, whether from testing or false alarms or real alarms, you will need to reset the power on the smoke detectors to take them out of their alarm state.

What is a PGM1?

The first thing to do is make sure your system has at least one programmable output, and to make sure it’s not already in use for something. It’s usually labelled as PGM1 on the circuit board, which stands for programmable output. The PGM output is kind of like an on/off switch.

What is the output of an alarm system called?

This article will discuss some possible uses for these outputs, and how to wire them into the circuit board. The alarm system output is generally called a PGM output.

Can you add PGM to your alarm?

You have successfully added to your alarm system. Keep in mind there are extra boards you can buy that have more PGM outputs on them. With enough PGM’s , you could make it so that your household lights are activated by the alarm system’s motion detectors. The possibilities are endless when you think outside the box.

What is a stay mode motion detector?

It's typically used for motion detectors when your system is armed in away mode, your motion detector will be armed, it will go off instantly. If your home and your system is armed in the stay mode , your motion detector will be bypassed.

Is it hard to program an alarm system?

Programming an alarm system is probably one of the most challenging aspects to DIY alarm installers. It's not difficult at all however if you take advantage of our programming quickstart guides and use our how to video tutorials. Below we'll show you how to program a DSC Power Series system.

What is a PGM siren?

A PGM output can activate a siren. PGM outputs on the DSC alarm system will activate when an event has occurred. You can program which event you would like to trigger an output. The output usually consists of an electrical current.

How to enter installer programming mode?

Enter installer programming mode by typing in "*8" and then your installer's code.

What does 00 05 do?

If you don't want an event to trigger the PGM, type "00" on your keypad. For example, entering "00 05" will disable PGM1 and will cause PGM2 to output when the alarm is armed. Advertisement.

1.Videos of How Do you Program Pgm Outputs on a DSC Alarm Syst…

Url:/videos/search?q=how+do+you+program+pgm+outputs+on+a+dsc+alarm+system&qpvt=how+do+you+program+pgm+outputs+on+a+dsc+alarm+system&FORM=VDRE

8 hours ago The most common that you will encounter are the two or four PGM's on the main PowerSeries panel. The PC1616 and PC1832 both have 2 PGM outputs. The PC1864 will have 4 PGM …

2.How to Program PGM Outputs on a DSC Alarm | Hunker

Url:https://www.hunker.com/12430103/how-to-program-pgm-outputs-on-a-dsc-alarm

34 hours ago  · 👉 content with alarm, video and other electronics is moved to a channel: https://www.youtube.com/channel/UCLm9BE1iWg9w1Mepg7RtYRwSimple tutorial to see how ...

3.What is a PGM output on a DSC PC1616, DSC PC1832, …

Url:https://www.alarmsystemstore.com/pages/dsc-pc1616-pc1832-pc1864-what-is-pgm-output

12 hours ago Type in "009" on the keypad to enter the PGM output option programming mode. Enter the two-digit code of the event that you would like to trigger the PGM1 output first, and then enter the …

4.HOW TO PROGRAMMING OUTPUTS PGM ON PARADOX …

Url:https://www.youtube.com/watch?v=wGXxCG3G-qA

13 hours ago How Do You Program PGM Outputs On A DSC Alarm System? Enter installer programming mode by typing in “*8” and then your installer’s code. Type in “009” on the keypad to enter the PGM …

5.Alarm System Outputs (Programmable Output) - Barnes …

Url:https://barnesprotection.ca/alarm-system-outputs-programmable-output/

13 hours ago  · Step 1: Identify your Programmable Output (PGM) The first thing to do is make sure your system has at least one programmable output, and to make sure it’s not already in …

6.DSC Power Series 1616, 1832, and 1864 Programming …

Url:https://www.alarmsystemstore.com/pages/dsc-power-series-1616-1832-and-1864-programming

7 hours ago You can simply do that by entering *6, your master code which by default is 1234, and then you can use your arrow keys and go through and do different things. I usually just typically just hit …

7.Using the PGM's on a DSC pc1616 - DoItYourself.com

Url:https://www.doityourself.com/forum/electronic-home-security-systems-alarms-devices/390236-using-pgms-dsc-pc1616.html

16 hours ago  · Received 238 Votes on 217 Posts. The PGMs are essentially programmable switches to ground (they can also do things like smoke det. power and 2-wire smoke support) …

8.Paradox Alarm System PGM Automation Programming …

Url:https://www.youtube.com/watch?v=NyI083kzYh0

34 hours ago How do you program a DSC smoke detector? To program the PGM follow these steps: Enter programming by typing in *8 and the installer code on a keypad. Go to programming section …

A B C D E F G H I J K L M N O P Q R S T U V W X Y Z 1 2 3 4 5 6 7 8 9