
How far should a toilet be from the stack?
If your waste line has a diameter of 3 inches, you can place the toilet within six feet of your stack. The toilet can also be as far as 10 feet from your stack, if the diameter of the waste line is 4 inches.
How far should a toilet vent be from the trap?
The first is to make sure the distance between your trap and vent is no more than 6 feet, which will allow it to work correctly with its outlet connected within this range as well! What is the toilet vent distance? The recommended distance between the toilet vent and the nearest inlet is 3 feet.
How far can a toilet vent be from the Wye?
The portion from the wet vent connection (wye) to the 90 elbow under the toilet has a max distance determined by the grade of the pipe (3" pipe, 12' distance). The wet vent portion, from the vent connection at the sink to the wye that connects the toilet has no distance limit (it actually goes vertical).
What size pipe is needed for a toilet vent?
And the size of this vent pipe depends on your local plumbing code. If your code is the IPC, then your toilet’s individual vent is sized at 1.5.” And that’s because individual vents in the IPC are sized at no less than one-half the diameter of the drain served. As you know, the minimum drain size for a water closet is 3 inches.

How far can you move a toilet from the stack?
The answer to how far you can move a toilet from the stack is less than 1.8 meters from the stack if the diameter of the waste line is 3 inches and less than 3 meters if the waste line is 4 inches or more. The issue is that the majority of custom homes in the United States are built with waste lines 3 inches or less in diameter.
Why is it important to measure the distance between the toilet and the stack?
It’s important to measure the distance between the toilet and the stack because this is going to determine whether you need a plumber to move your toilet away from the stack or if you can do it yourself. Some plumbers can help you with the installation of a flushometer, but others will charge an additional fee if they have to install a flushometer.
What is the tank in a toilet?
Toilets are made up of a bowl and a tank that sits on top of the bowl which holds the water for flushing. The water that is flushed out of the toilet bowl is sent into an underground drain that empties into the sewer or septic tank.
Is it dangerous to move a toilet from a stack?
Removing the toilet from the stack is a very big job and requires special tools for getting it out. It’s done by professionals who have been trained to do this kind of work. It’s expensive to move a toilet from the stack and it’s also dangerous. The biggest issue with moving a toilet is the fact that the pipe is not always accessible.
Is it hard to install a flushometer?
The issue with installing a flushometer is that it’s not that difficult to get something wrong. Not only does it need to be positioned correctly, but they’re also needs to be enough space around the toilet for the rubber gasket to expand.
Can you move a toilet further from the stack?
The short answer is yes , it is possible to move a toilet further from the stack. But there are certain things you should keep in mind before taking such a step. First, let’s go over some basic information about toilets. Toilets are made up of a bowl and a tank that sits on top of the bowl which holds the water for flushing.
Is it expensive to relocate a toilet?
It is a bit costly to move a toilet and that is usually relative, however, the average price to relocate a toilet is anywhere from $1,500 to $3000. Several factors will contribute to the cost. It’s important to remember that even if you do plan on moving your toilet further from the stack, you need to make sure that your tank is still accessible and install a flushometer in the tank.
How far does a toilet vent go?
No. The portion from the wet vent connection (wye) to the 90 elbow under the toilet has a max distance determined by the grade of the pipe (3" pipe, 12' distance). The wet vent portion, from the vent connection at the sink to the wye that connects the toilet has no distance limit (it actually goes vertical). The portion from the vent connection to the sink is limited by the grade of the pipe (distance will vary as the pipe could be 2", 1-1/2", or 1-1/4" for a bathroom sink).
How high above the floor should a grey vent be?
The grey vent would be a dry vent, however the issue here would be that in most locations, you are not allowed to run the dry vent horizontal until you are 6" above the flood level of the fixture is serves and at minimum 42" above the floor.
What is a wet vent?
Definition of a wet vent: a drain pipe that also serves as a vent pipe and extends from the most downstream wet-vented fixture connection to the most upstream fixture connection (the green item 4 in the below sketch). Wet vents are typically used when plumbing a bathroom group.
How far is a fixture drain?
Fixture Drain(toilet): Distance is limited by the diameter of the pipe as the fall cannot exceed the pipe diameter. If 3" the distance would be 12' measured from the connection to the wet vent (where violet meets green).
Where is the toilet WC located?
The left sketch shows a typical arraignment when the toilet (WC) is located in-between the sink (LAV) and shower (SH). This arraignment relies on the use of a double wye fitting to avoid lines crossing while maintaining the toilet as the last fixture connected to the wet vent.
How many Q&A communities are there on Stack Exchange?
Stack Exchange network consists of 178 Q&A communities including Stack Overflow, the largest, most trusted online community for developers to learn, share their knowledge, and build their careers.
Can a shower be vented by a wet vent?
Wet vents are typically used when plumbing a bathroom group. So yes the shower can also be vented by the wet vent along with the toilet . There is one major stipulation when wet venting multiple fixtures when a toilet is one of them: the toilet must be the last fixture connected to the wet vent. This means that in some situations you must use ...
How far above the roof should a vent be?
EXCEPTION: Where a roof is used for any purpose other than weather protection, vents shall extend at least 7 feet above the roof and shall be properly supported.
How high should a roof vent be?
904.1 Roof extension. All open vent pipes that extend through a roof shall be terminated at least [NUMBER - typically 6 ] inches (mm) above the roof, except that where a roof is to be used for any purpose other than weather protection, the vent extensions shall be run at least 7 feet (2134 mm) above the roof.
Why is a larger piping diameter needed?
Basically,larger piping diameter allows longer distances between a plumbing fixture and its vent stack. If a plumbing fixture is located too far from the main building vent stack, then its own drain pipe must have its own vent stack connection piping.
What plumbing fixtures need special routing and connections?
Special routing and connections are required for proper venting of plumbing fixtures such as kitchen island or peninsula sinks or dishwashers - plumbing fixtures that are located where a direct vertical vent stack connection is not possible.
What is the minimum size of a vent extension?
Where the 97.5-percent value for outside design temperature is 0ºF (-18ºC) or less, every vent extension through a roof or wall shall be a minimum of 3 inches (76 mm) in diameter. Any increase in the size of the vent shall be made inside the structure a minimum of 1 foot (305 mm) below the roof or inside the wall.
How far is a vent from a window?
Nearest window, door, opening, air intake, or ventilation shaft: distance to plumbing vent. 10 ft (120-inches) from nearest window, measured horizontally.
How much slope does a drain have?
The usual slope on the fixture drain piping is 1/4" of slope per 12" (foot) of horizontal distance or "run" of piping.
How many ways can you vent a toilet?
Illustrations for the 4 ways in which you can vent your toilet are documented below.
How to tell if toilet is vented?
In general, you can tell whether your toilet is correctly vented or not when it can’t flush correctly, has bubbles and the water level in the bowl keeps rising or falling.
Why does a Toilet Need a Vent?
However, these gases need to be released since without a vent the toilet becomes a closed system. Therefore, the reasons your toilet need venting include the following:
What is a wet vent?
Wet venting entails venting a toilet through another fixture and is permeated by both the Uniform Plumbing Code (UPC) and the International Plumbing Code (IPC) since it saves on space and time. Given that wet venting uses pipes with both air and water, the size of the venting pipe must be at least 2 inches in diameter for the venting to work properly.
Why do toilets have air admittance valves?
This prevents the problems associated with bad venting which include bubbling toilets and rising and dropping water levels in the toilet bowl.
How does a toilet vent work?
The venting system of your toilet is based on how liquids and gases work in terms of their weight and response to behavior. Since wastes and liquids are heavier than gases, they usually occupy the lower sides of the pipes with the gases occupying the upper sides of the same pipes. Venting allows a balance of pressure between them to allow ...
What is a P trap in a toilet?
This setup ensures that the toilet flushes properly, prevents the entry of sewer gases into the home and doesn’t get clogged up with time . The venting system of your toilet is based on how liquids and gases work in terms of their weight and response to behavior.
How far can a toilet vent?
In the UPC, the toilet’s trap to vent distance is limited to 6 feet.
How long can a toilet trap arm be?
If you’re in the IPC, there is no limitation in length for the toilet’s trap arm. That’s right, no limitation! That means your fixture drain can have an unlimited distance (909.1). Keep in mind your toilet still needs a vent, but your trap arm can be as long as necessary.
What is the purpose of a 3 inch vent?
The purpose of this oversized vent is to meet the UPC’s aggregate venting requirement.
How big are IPC vents?
And that’s because individual vents in the IPC are sized at no less than one-half the diameter of the drain served.
Where is the toilet vent wye?
This wye is positioned right under a wall. This allows the toilet vent takeoff to be vertical (that’s important).
What is a P trap?
Inside a p-trap is 2-4 inches of standing water. This standing water is called the trap seal. The trap seal is what blocks sewer gas from invading into your home.
Where is the trap seal on a toilet?
Did you know when you open the lid of your toilet, you’re looking at the top of the toilet’s trap seal.
How far away from a toilet can you put a toilet?
If your waste line has a diameter of 3 inches, you can place the toilet within six feet of your stack . The toilet can also be as far as 10 feet from your stack, if the diameter of the waste line is 4 inches. What about toilet flush systems?
How far can you relocate a toilet?
This will result in a lot of investment at your end. However, you can also move the toilet to a certain extent without having to change the waste line and stack. If your waste line has a diameter of 3 inches, you can place the toilet within six feet of your stack. The toilet can also be as far as 10 feet from your stack, if the diameter of the waste line is 4 inches.
Why do you need a vent pipe in a toilet?
The vent pipe plays a crucial role in maintaining sufficient air pressure in the waste pipe. You will need to align the waste pipe correctly with the vent pipe to ensure smooth functioning of the toilet.
What to consider when moving a toilet?
Because relocating a toilet is not be an easy affair, there are some key factors that you should consider before deciding to move your toilet. 1. Toilet drainage. The waste pipe of your toilet needs to be connected to the vertical sewer pipe.
How much does it cost to move a toilet?
The plumbing costs depend on a number of factors. If you are looking to change your toilet location, you can expect to spend anywhere between $2500 and $3500 in normal circumstances.
Can you break into a toilet floor?
You may need to break into the floor to do the plumbing. If your toilet is not on the ground floor, the relocation exercise will require you to rebuild the ceiling of the underlying floor along with the toilet flooring.
Can you actually move a toilet and if so how far?
Yes, you can actually move a toilet. Even moving a toilet by a few inches without having to make a new hole in the floor is possible. You can use an offset toilet flange to move the toilet by a couple of inches on any side. This will allow you to use the same wastewater line and in turn help to save you a lot of money.
