How long to heat water with electric 50 gallon?
In that case, your 50-gallon water heater can take 80 minutes to heat the water to your preferred temperature. If the temperature is 40 degrees Fahrenheit, a similar water heater setup can take about 110 minutes to complete. A 70-degree Fahrenheit temperature can reach 120 degrees in about 66 minutes.
How much does a 50 gallon electric hot water heater cost?
50-Gallon Electric Water Heater Cost Expect to pay $450 to $1,500 for a 50-gallon tank or $1,400 to $2,500 for a hybrid heater. A 50-gallon electric water heater supports three to four people with average use.
What is the highest rated electric water heater?
- IN A HURRY? ...
- 10 Best Electric Tankless Water Heaters Reviewed 1. ...
- Tankless Water Heater Systems Buying Guide Activation Flow Rates Tankless Electric Water Heater Models Manufacturer’s warranty offer Energy efficiency or low energy cost rating Demand for usage Type of electric ...
- Tankless Electric Water Heater Vs. ...
What is the best brand of electric water heater?
- BEST OVERALL: Rheem Performance Platinum 50 Gal. Water Heater
- RUNNER UP: A.O. ...
- BEST BUDGET: Rheem Performance 50 Gal. ...
- BEST TANKLESS ELECTRIC: Stiebel Eltron Tankless Water Heater, Electric
- BEST TANKLESS GAS: Rinnai High Efficiency Natural Gas Tankless Heater
- BEST ENERGY-EFFICIENT: Rheem Performance Platinum Hybrid Electric Heater
- ALSO CONSIDER: A.O. ...

What size breaker do I need for a 50 gallon electric water heater?
An electrical water heater typically uses a 30-amp breaker, so something like the Q230 30-Amp Double Pole Type QP Circuit Breaker will do the work well.
How many amps does an electric hot water heater take?
18.8 ampsWhat is the Standard Amperage for an Electric Water Heater? Most electric water heaters use 18.8 amps with 240 volts and a 4,500 watt heating element. A gas water heater uses less amps—about 12 Amps with 115 volts.
Can I use a 50 amp breaker for a 30 amp water heater?
30 amps is where a 30 amp breaker should cut off, and to avoid that, you should only use 80% of the breaker's capacity. So for a 30 amp breaker, you shouldn't be using more than 24 amps. Using a 50 amp breaker and a dedicated outlet ensures that you don't exceed the capacity of the circuit with that appliance.
How do I know how many amps my water heater is?
If it is a 4.5kW heater, and if it has dual elements, then each element uses 2,250 watts. That's 18.75 amps. If it has dual 4.5kW elements, it is a 9000 watt heater. That's 37.5 amps.
How many amps is a 60 gallon water heater?
60 gallon (240v) water heaters require: Voltage 208 or 240. Conductor Size 10/2. Fuse Size 30 amps.
How long does it take a 50 gallon 4500 watt water heater to heat up?
Gas Hot Water Heater Recovery Water coming into a 50-gallon tank at 40 degrees takes just 53 1/2 minutes to reach 120 degrees. For 60-degree water entering the tank, calculate about 40 minutes needed for the water to reach the 120-degree temperature. For 70-degree water, it would take 33 minutes.
What's the difference between 30 amp and 50 amp?
A 30 amp plug has three prongs – a 120 volt hot wire, a neutral wire and a ground wire – and is generally used on RVs with lower load requirements. A 50 amp plug has four prongs – two 120 volt hot wires, a neutral wire and a ground wire – that supply two separate 50 amp, 120 volt feeds.
Why does my water heater keep tripping the breaker?
It could be a loose or bad wire, a bad connection in the electrical panel, or a worn-out breaker. Check the wiring on the line for broken or loose wires. If the breaker trips and there are no problems on the line, then you'll need to replace the breaker.
What size breaker do I need for a dual 4500 watt water heater?
Conclusion. To sum it up, you can either use a 25-amp or 30-amp breaker for a 4,500-watt heater. For wiring, you can choose between a 10-gauge wire or a 10/2 wire for this setup.
Can I use a 40 amp breaker for water heater?
No problem. If you really want the 40 amp breaker check the wire size going to your 30 amp breaker (see above advice from ratchet freak: "you will need to know the gauge of the wire all the way from the breaker to the heater.") If it is #10 wire you'd have to re-wire with #8.
What size wire can handle 30 amps?
10-gauge wire“Twelve-gauge wire is good for 20 amps, 10-gauge wire is good for 30 amps, 8-gauge is good for 40 amps, and 6-gauge is good for 55 amps,” and “The circuit breaker or fuse is always sized to protect the conductor [wire].”
What size breaker does a water heater need?
30-ampElectric water heaters require a 240-volt dedicated circuit, which serves only the water heater and no other appliances or devices. The circuit wiring typically includes a 30-amp double-pole breaker and 10-2 non-metallic (NM) or MC cable.