How to install a Studor vent for a kitchen sink?
Studor Vent, commonly known as Air Admittance Valves (AAVs), is a negative pressure-activated one-way vent. It is basically used in a drainage system to balance the air pressure inside. When there is a water flow in the sewer system, the water needs to flow smoothly. Otherwise, it will be stuck somewhere in the drainage system.
How to use a soffit vent?
What is a studor vent? Studor Air Admittance Valves (AAVs) are negative pressure-activated, one-way vents, used in a drainage system to eliminate the need for passive pipe venting and unsightly, costly roof penetrations. Click to see full answer. People …
What states allow air admittance valves?
Oct 12, 2019 · What is a studor vent and what does it do? Why is it under my sink?
What is the purpose of a vent stack?
Studor vents are used when a drain line and Vent aren’t connected to toilets. Methane comes up the sewer line on all drain lines but vents to outside air, to keep any pressure building in the pipe. The Studor vent lets that air to be sucked in the pipe …

What is the point of a studor vent?
The Studor vent lets that air to be sucked in the pipe during water flow but doesn't let sewer gas escape out. Code is the thing that determines pipe size and also water flow. Hence no studor vents are permitted to toilets because more air is required to keep water flow going with more waste added to the toilet.Feb 28, 2021
Do studor vents smell?
We had a strong sewage smell develop in our powder room that I traced to under the vanity. I replaced the air admittance valve installed there with a new studor mini vent and the smell went away immediately. Surprisingly fast in fact.Oct 29, 2018
How do you run a studor vent?
4:045:36Studor Air Admittance Valves Revolutionizing the Plumbing IndustryYouTubeStart of suggested clipEnd of suggested clipAfter applying teflon tape to the threads of the valve. The valve is screwed into the adapterMoreAfter applying teflon tape to the threads of the valve. The valve is screwed into the adapter fitting. The many hours of installing vent piping is reduced to a simple time-saving installation of an A.
How many fixtures can you have on a studor vent?
A single vent serves as the vent for three to eight fixtures. The Studor Mini-Vent or Tec-Vent serves as the circuit vent. When the horizontal drainage branch connects to a stack having more than four branch intervals located above the branch, a relief vent is required.
Why does my house smell like sewer gas?
If you are detecting foul sewer odors inside the house, this means that there is a weak link somewhere in your plumbing system. Possible sources include bathroom sink drains, toilets, kitchen drains, basement drains, old cast iron piping, or even the vent stack that goes out through your roof.Jul 15, 2016
Why does the vent under my sink stink?
A rancid odor coming from your sink drain may just be coming from debris in the P-trap, but if it smells like a sewer, it probably means venting problems in your drain system. When the vents are blocked, flushing a toilet can create sufficient vacuum to suck water out of the trap and allow sewer gases into your home.
Where are Studor vents located?
Air Admittance Valves (aka Studor vents) are “negative-pressure-activated” one-way mechanical valves. Used most commonly at an island sink or vanity the vents are also located in the attic to prevent the roof penetrations (as seen above) on the front roof line elevation.
Can you vent a shower with a Studor vent?
Studor vents help to facilitate drainage in bathtubs and showers. Often, when a bathtub, shower or washing machine is bubbling or gurgling, either a Studor vent needs to be installed or an existing vent is locked in the open position.Feb 21, 2017
Can you vent a toilet with a Studor vent?
Things You'll Need Studor, a brand name air admittance valve, can solve venting problems when open air venting pipes will not work. Studor vents allow air to enter the pipes while keeping sewer gasses or odor from escaping. After a toilet flushes the increased water flowing down the drain creates a negative pressure.
Can a studor vent be in a wall?
You can cover it with a vent grill on the wall of your heating/cooling system, but you can't bury it in a wall. It won't be hard to find the smell when the AAV fails.
Does a kitchen sink need a vent?
A kitchen sink drain needs to be vented so as to prevent clogging and ensure free flow of water and liquids from the sink. also, venting a kitchen sink allows air to enter behind the water that is flowing out. This prevents debris, oil, and fat, from sticking on the wall of the drain.Jul 26, 2021
Do studor vents meet code?
Developed in Europe back in the '70s, the Studor Air Admittance System (Studor, 800/447-4721, www.studor.net) was introduced in the United States in 1988. Now, AAVs are accepted by virtually all national building codes, including the SBCCI, BOCA, IRC, and IPC plumbing codes.
How does a sewer line work?
Sewer lines have a vent line that eventually goes via the roof at some point to let air in or out the sewer line. As you drain a large slug of water via the sewer line if the air isn’t allowed to enter and exit freely it’ll do that glug-glug thing you see when you turn a bottle of water down and let it get drained.
How long is a plumber's warranty?
The United States manufacturers provide warranties that range from one year to a lifetime. You should seek out the warranty information. Most plumbers will not have it. Note: An AAV shouldn’t be tampered with or spray painted. Some plumbers said that sewer flies and bugs are seen at failed air admittance valves.
Can studer vents fail?
Some state and local building departments prohibit Studer vents. check with the local AHJ (Authority Having Jurisdiction) for more information. Studer vents are certified to reliably. However, anything mechanical can and will fail. Few manufacturers claim they are better for 500,000 uses (about 30 years of use).
Does sewer gas smell?
Inside the vent line, there is air as well as sewer gas. Sewer gas doesn’t smell pleasant at all. Negatives are the Air admittance valve has moving parts, therefore, requires a maintenance and inspection program.

The Pros
- The studor vent can significantly decrease the number of venting materials required in a plumbing system. They let greater flexibility in the layout of plumbing fixtures decrease long-term roof maintenance. If we do not have a hole in the roof, it is easier to maintain the roof. Studer vents are efficiently used in Europe for more than 2 decades. However, there are some limitations.
The Cons
- Some state and local building departments prohibit Studer vents. check with the local AHJ (Authority Having Jurisdiction) for more information. Studer vents are certified to reliably. However, anything mechanical can and will fail. Few manufacturers claim they are better for 500,000 uses (about 30 years of use). The United States manufacturers provide warranties that …
When Is It Important to Use A Studor Vent?
- Studor is a brand name. Basically, a one-way valve for air. Sewer lines have a vent line that eventually goes via the roof at some point to let air in or out the sewer line. As you drain a large slug of water via the sewer line if the air isn’t allowed to enter and exit freely it’ll do that glug-glug thing you see when you turn a bottle of water do...
Inspecting The Studor AAV
- STUDOR AAVs must be situated a minimum of 4-inches above the horizontal branch drain and fixture drain being vented.
- STUDOR AAVs shall be accessible. For in-wall installation, utilize STUDOR recess box and grill combination.
- STUDOR AAVs location must let for enough air to enter the valve. When located in wall spac…
- STUDOR AAVs must be situated a minimum of 4-inches above the horizontal branch drain and fixture drain being vented.
- STUDOR AAVs shall be accessible. For in-wall installation, utilize STUDOR recess box and grill combination.
- STUDOR AAVs location must let for enough air to enter the valve. When located in wall space and attic space lacking ventilation openings, the opening shall be provided. Locating the valve in a sink...
- STUDOR vents should be installed in the vertical, and upright position. A maximum deviation of 15 degrees is allowed.