How to tell if an expansion tank is working?
- Standing next to the tank, with your timer in hand, tell/shout to your partner to turn on the cold water at the sink. ...
- Keep your eye on the pressure gauge, with your timer in hand. Don’t start the timer yet. ...
- Continue to watch the needle drop. ...
- While your timer is counting, watch the needle on the gauge rise. ...
- Check your timer. ...
How to replace an expansion tank?
Steps for Installing a Thermal Expansion Tank
- Turn off the water and power supply to the water heater. ...
- Prepare the water heater expansion tank. Unbox the expansion tank kit and lay the components on a clean surface. ...
- Look for the water pipe supplying cold water to the water heater. ...
- Prepare the area for mounting the expansion tank. ...
Do water heater expansion tanks go bad?
Water heater expansion tanks only last for 10 years on average, but they can go bad before then. Replace your water heater expansion tank if it is nearly 10 years old and multiple parts need to be replaced. Otherwise, replace the expansion tank if it is broken and has holes in it.
Why is my water heater expansion tank leaking?
- Take a piece of metal pipe and tap the expansion tank from top to bottom. If the expansion tank is waterlogged, it will sound quite solid from top to bottom. ...
- Remove the air inlet cap and try to bleed air from the tank. ...
- Connect a pressure gauge to the air inlet valve and check the pressure of the air in the tank. ...

Do I need an expansion tank on my boiler?
An expansion tank is required on all closed loop heating boiler systems. As a boiler heats the system water, the water will expand in volume. Water cannot be compressed but air can, so an expansion tank uses air (or an inert gas like nitrogen) that acts like a cushion or spring against this force.
What happens when a boiler expansion tank fails?
Oftenthe diaphragm dividing the two systems will fail, causing the two systems to become one. When this happens, the expansion tank turns into a “dead leg” that will eventually cause damage and premature failure to your water heater.
Are expansion tanks really necessary?
An expansion tank is a necessary component in most homes. This simple device will keep both your water heater and your appliances running smoothly without causing damage. Furthermore, if you live in cold weather, it is essential to have an expansion tank installed on the hot water supply line of any heating unit.
Why do expansion tanks fill with water?
Some tanks fail when a leak develops in the diaphragm. This usually causes the tank to fill with fluid and become “water logged.” You can check for this by pressing in the stem of the Schrader valve. If a stream of liquid comes out the tank is toast. Tanks can also develop leaks in their thin steel shell.
How do I know if my boiler expansion tank is bad?
If your Thermal Expansion Tank is hanging from a pipe, you would push the Schrader Valve (air valve), located on the bottom of the tank, if the air is released then the tank is working properly. If nothing or water comes out your tank is bad and needs to be replaced.
How often do expansion tanks need to be replaced?
between five and 10 yearsBut expansion tanks can wear out. The average life of your tank can be anywhere between five and 10 years. You can extend the life of your expansion tank by making sure that your home's water pressure matches the air pressure in your expansion tank. But in some cases, you'll need to replace it.
What happens if expansion tank pressure is too low?
If the psi is too low, you'll need to add some air with a tire pump. We highly recommend using a hand pump instead of an air compressor when adding air. An air compressor could easily rupture the bladder.
Where should the expansion tank be installed on a boiler?
The expansion tank needs to be installed on the suction side of the hot-water circulator, on the bottom of the supply line. The boiler system is then re-pressurized and should be checked for any leaks. If leaks are found in the system, they need to be repaired to prevent any pressure drops.
Where should the expansion tank be installed?
Your expansion tank can be anywhere on your plumbing system and does not need to be installed in close proximity to the water heater. It is most commonly installed using a “T” at the cold inlet to the water heater. But, functionally, it can be installed anywhere on the cold inlet line.
Do expansion tanks need to be drained?
Draining water out of a waterlogged expansion tank is a common heating boiler service procedure used to replace a lost air charge. If this step is not taken when needed the waterlogged compression / expansion tank will cause boiler leaks and improper, even unsafe boiler operation.
How much does it cost to replace a boiler expansion tank?
You may be able to go six to 12 years or more before needing to replace your expansion tank. At $90 to $350, hot water heater expansion tanks are usually much more affordable than the cost of hot water tanks themselves, which average about $1,190.
What causes an expansion tank to fail?
Air Blockage Your expansion tank is designed as a place for air to sit in your hot water system. Air is a needed element in these systems. But air can get trapped and cause what is known as a hydronic airlock. This kind of air block can stop water from passing through the heater and the pipes.
How much does it cost to replace an expansion tank on a boiler?
FAQs About Hot Water Heater Expansion Tanks You may be able to go six to 12 years or more before needing to replace your expansion tank. At $90 to $350, hot water heater expansion tanks are usually much more affordable than the cost of hot water tanks themselves, which average about $1,190.
How do you know if your expansion vessel is broken?
If you think the vessel has failed, unscrew the plastic cap from the pressurisation valve (it's like a car tyre valve). Momentarily depress the pin in the valve to release a little pressure. If water comes out of the valve you have a definite expansion vessel fault.
What makes an expansion tank go bad?
A common problem that an expansion tank can encounter is lack of proper air charge. It should have the right charge at installation; however, if the tank begins to develop an air leak, it can have too much water and too little air inside it.
What happens if expansion tank pressure is too low?
If the psi is too low, you'll need to add some air with a tire pump. We highly recommend using a hand pump instead of an air compressor when adding air. An air compressor could easily rupture the bladder.
How does an expansion tank work?
The expansion tank does the job of maintaining even pressure inside the boiler by giving its water a place to expand and a cushion to absorb the pressure and then regulate it . Inside the expansion tank, a diaphragm divides the chamber into two sections. On one side, water from the boiler tank flows in through a pipe;
What is expansion tank?
That’s the expansion tank. Although the name may make it sound like it’s a container for extra water, that’s not how boilers work. (They have a set amount of water already in them, and more water won’t make them work any better.) The expansion tank does the job of maintaining even pressure inside the boiler by giving its water a place to expand ...
How does a boiler tank work?
On one side, water from the boiler tank flows in through a pipe; on the other side is air controlled by a valve. When the pressure in the boiler increases, the water in the expansion tank presses against the diaphragm and the air on the other side, which alleviates the pressure.
Why do boilers have an expansion valve?
The expansion valve keeps the air and the water separate.
What is boiler 101?
Boiler 101: The Expansion Tank. Boilers have advanced tremendously during the more than a century that they have heated businesses and homes. Few boilers use steam any more to send heat through their pipes, and the cast-iron radiators of yore have gradually vanished in favor efficient baseboard heaters.
What Is an Expansion Tank?
An expansion tank is designed to relieve pressure in both potable water and closed hydronic heating systems. It ensures that constant pressure is maintained within the pipes so they do not get damaged from excess pressure. “An expansion tank in a heating system is an invaluable component that protects the entire system from the increased pressure and volume caused by heating,” asserts Daniel O’Brian, a technical expert from online retailer SupplyHouse.com.
How does an expansion tank work?
Expansion tanks work by equalizing pressure throughout the system . An expansion tank is a small tank divided in two sections by a rubber diaphragm. One side is connected to the pipes of the heating system and contains water. The other side is dry and contains pressurized air, set at approximately 12 psi. As hot water enters the heating system, the pressure in the system increases. As pressure increases, the diaphragm in the expansion tank is pushed down. This compresses the air in the tank, creating more space for excess water to enter. This relieves excess pressure in the system and prevents pipes in the system from being damaged.
What happens when the pressure in an expansion tank increases?
As pressure increases, the diaphragm in the expansion tank is pushed down. This compresses the air in the tank, creating more space for excess water to enter. This relieves excess pressure in the system and prevents pipes in the system from being damaged.
How many gallons does an expansion tank hold?
Expansion tanks vary in capacity, ranging from tanks that hold as little as two gallons to large tanks that hold several hundred gallons. To determine the size needed for your system, online retailer SupplyHouse.com offers a handy Expansion Tank Sizing Calculator on its Web site. Use it to determine the size and model of the expansion tank that’s best suited for your system.
How long does it take to install an expansion tank?
Installing an expansion tank is a relatively simple process that can typically be completed in less than an hour by a handy do-it-yourselfer. Some local building codes may require installation by a licensed plumber, however, so you should check with your municipal building department before proceeding with any installation.
What happens if a water tank is warm?
If the entire tank is warm, it is likely that the tank has completely filled with hot water, which occurs only if the diaphragm fails.
Why do boilers use expansion tanks?
These expansion tanks are used to provide a cushion for the expansion of water when it is heated. Without this cushion of air, the pressure in the boiler system would exceed the setting on the pressure relief valve. Finally, this will cause the pressure relief valve to open and discharge water to relieve the pressure.
Why is it important to understand the expansion tank?
This understanding is important to properly troubleshoot hot water boiler problems, which may occur as a result of an issue with an expansion tank .
What happens if the bladder expansion tank is not maintained?
If an incorrect bladder expansion tank is in place or the proper air pressure on the airside of the bladder expansion tank is not maintained, then the relief valve will discharge intermittently.
What is the purpose of a bladder type expansion tank?
The bladder-type expansion tank serves the same purpose that the steel expansion does; it absorbs the extra pressure created in the hot water boiler hydronic loop when the water in the hydronic loop is heated . Furthermore, some well systems have expansion tanks to absorb the pressure induced by the “well pump”.
How does expansion tank sizing work?
Expansion tank sizing happens according to an equation in the mechanical codes. However, most boiler manufacturers will give you sizing charts based on the BTU/h output of the system. Additionally, another factor includes the type of convectors you have in the loop, such as copper baseboard or cast iron radiators.
Where to install bladder expansion tank in hydronic loop?
For better performance and for reducing the problem of air absorption into the loop system it is best to install the bladder expansion tank just before the suction side of the circulator pump in the supply side of the hot water boiler system hydronic loop .
When to charge bladder expansion tank?
It is best to charge the tank when it is totally disconnected from the boiler loop. Hopefully, the boiler installation crew added a ball or gate valve to the line coming from the boiler loop going to the bladder expansion tank.
What is an expansion tank?
Furthermore, an expansion tank is a shock absorber that absorbs this expansion and contraction of the volume of the water.
What is an expansion tank in hydronics?
Therefore in every hydronic system, there is an expansion tank to handle this expansion and contraction. Furthermore, an expansion tank is a shock absorber that absorbs this expansion and contraction of the volume of the water.
Why is expansion tank important in a closed loop?
That is a closed loop where the water runs to these convectors or coils to provide heating or cooling. Furthermore, it is important to maintain the proper pressure inside that closed-loop piping system — an expansion tank helps to maintain the proper pressures in the loop.
Why do steel tanks need maintenance?
Additionally, the steel-type expansion tank needs some basic maintenance from time to time to ensure it doesn’t become waterlogged or overfilled, which would defeat the purpose of having an expansion tank. Furthermore, for more on the basic maintenance of a steel expansion tank and how to properly fill it check out this article.
Why should a tank be supported?
Lastly, ensure tanks are properly mounted and installed at the proper location. Additionally, the tank should be supported to prevent stress on connecting piping.
Why does my pressure relief valve vent unnecessarily?
Test the level in the tank to ensure it is not waterlogged or overfilled. Additionally, this can cause problems with the loop and cause the pressure relief valve to vent unnecessarily.
What is an expansion tank?
Today, the most commonly-specified expansion tank for hydronic heating or cooling systems uses a highly flexible butyl rubber or EPDM diaphragm to completely separate the air and water inside the tank. This diaphragm conforms to the internal steel surface of the tank when the air side is pressurized, as shown in Figure 2.
What is an expansion tank in hydronics?
The tank provides a “cushion” of air–a highly compressible fluid–against which the expanding water can push without creating large pressure increases in the system. Think of the air in the tank as a spring. As the system’s water expands this “spring” gets compressed. When the water cools and contracts, the “spring” returns to its original condition.
What temperature should an expansion tank be?
Do plan for lowest fluid temperatures: In most hydronic heating systems expansion tank size and air side pressurization is based the assumption that the cold fluid used to fill the system in the temperature range of 45F to 60F. That is fine. However, when an expansion tank is used in a solar collector circuit, or a snowmelting system, the antifreeze solution will, at times, be much colder, perhaps even below 0F. If the tank’s diaphragm is fully expanded against the steel shell at a fluid temperature of perhaps 45F, any further cooling of the fluid could cause negative pressure in the system and possible inflow of air from a float-type vent. Reference 2 below explains how to correct for this possibility. The concept is to add sufficient fluid to the tank during loop pressurization so that the diaphragm is not completely expanded against the inside of the tank until all fluid in the system is at the lowest possible temperature.
What happens when water expands into a water tank?
When the system’s water is heated and expands into the tank, the diaphragm deforms and moves toward the captive air chamber. The air pressure in the tank increases and so does the water pressure in the system.
Why pressurize the air side of the expansion tank?
Pressurizing the air side of the tank to equal the static pressure of the water at the expansion tank location and before adding water to the system. This prevents cold water from partially compressing the air in the tank. The diaphragm only begins to compress when the water temperature rises. 2.
How to check if a tank is water logged?
This usually causes the tank to fill with fluid and become “water logged.”. You can check for this by pressing in the stem of the Schrader valve. If a stream of liquid comes out the tank is toast. Tanks can also develop leaks in their thin steel shell. The only option is a new tank.
When does the diaphragm compress?
The diaphragm only begins to compress when the water temperature rises. 2. Size the tank so that the pressure at the system’s pressure relief valve is 5 psi below that valves rated opening pressure when all fluid in the system is at maximum anticipated temperature.