how far does a chimney have to be from a window

by Emil Bernhard Published 2 years ago Updated 2 years ago
image

If your chimney is two feet above the ridge of a roof over the one story addition, if you can't get more than 12 feet of horizontal distance between chimney and windows of the upper floor, you probably need to extend the chimney above the upper roof, following the ten-foot horizontal line rule we describe above.

Full Answer

How far above the roof should a chimney be above?

If your chimney is two feet above the ridge of a roof over the one story addition, if you can't get more than 12 feet of horizontal distance between chimney and windows of the upper floor, you probably need to extend the chimney above the upper roof, following the ten-foot horizontal line rule we describe above.

What is the minimum height of a chimney vent?

For a gas vent or Type L vent this height must be 2 Ft (0.61m) or more. The top of the flue opening (termination of the chimney) should be a minimum of 2 feet above any part of a structure within ten feet. Vertical blue arrow in our sketch.

How do you measure chimney clearance distance?

Horizontal chimney clearance distance measurements are made between the building surface (roof or nearby wall or other nearby roof surface) and the nearest facing surface of the chimney side. Above: metal chimney minimum roof clearance illustration adapted from Dura Vent installation instructions cited just below.

How close to a chimney can you build a twin wall?

With a modern twin wall system you should get away with 3.5m or even 3m if you have to (e.g. out of a shed or caravan or boat). 4. If you have a window anywhere near then check out the regulations (ADJ diagram 17). 5. There must be no bends greater than 45 degrees and there must be no more than four bends in the chimney.

What is a chimney connector?

Why do you put a stovepipe through a window?

How to keep cold air from entering house?

How to install a window that won't break?

How to keep smoke out of a house?

See 2 more

About this website

image

Vent a woodstove through a window? | Graybeard Outdoors

i did basically what your talking about when i built my house.in my mudroom i framed in a 2'x2 'hole in the back wall.tacked a thin sheet of metal on the outside wall with a hole for the stove pipe.ran stove pipe thru it and then bricked around the pipe. then i made a chimney out of 8 in well caseing. its worked fairly well for 15 yrs or so. you will want to keep your horizontal pipe to a ...

Wood stove vent through window | Hearth.com Forums Home

I imagine it could be done (I wouldn't I just now finally paid for this house) figure out where you would want to place the stove so its best suited for the application, then see if its feasible to go straight through the roof (cheaper, and safer) or cut a hole in the wall and do it the right way. post a floor plan in here and the members will help ya figure it out.

Running a Stove Pipe Out The Basement Window? | ThriftyFun

I have a corn stove I was going to hook up in my basement. Someone suggested since my window was broke, why dont I run the pipe out that window. It comes with a wall fitting around the pipe. But I have to hold it in the window. I didnt want to use plywood.

The Correct Direction to Install Wood Stove Pipe - Rockford Chimney Supply

The male end of the stove pipe for wood burning should always point down and/or pointing at the stove. Also, the wood stove pipe should always be inserted into the collar of the stove outlet. We understand this concerns some homeowners, but we wi

Chimney through basement window opening? - Hearth.com Forums Home

I am planning on installing an Englander 28-3500 add on furnace and I'm lucky enough to have what I think is an ideal layout in my basement. On the west wall of my house there is a basement window which is not far (about 8 feet) from my oil burner. The window is a standard basement window size...

chimney distance from windows

i am getting some building work done and no one seems able to tell me what the minimum distance a velux window can be from a chimney. i want the window to be an opening one so it needs to fulfill that criteria, but i have;nt a clue what it is, or whether this distance is horizontal, vertical or both. can you help???

Answers

No best answer has yet been selected by mumandmore. Once a best answer has been selected, it will be shown here.

Kitchen Chimney on the window dilemma

I have positioned my Hob under the window and need to install the chimney on the window now. I understand that I need use a plywood panel on the window to install the wall mount chimney. However, I really don't want to do that since it would block out the natural light. I am exploring alternatives for the same .

Comments (2)

The distance between chimney and hob needs to be 26"-30" : 65cm-80cm. placing it above the window, suction power is reduced, placing it in middle of the window, will make the window ineffective. Island chimneys are best suited to be positioned in middle of the room, the duct running through false ceiling.

How tall is a chimney?

Keep in mind that there is generally a minimum chimney height requirement for the overall system (usually 15 feet, which sometimes includes connector pipe) that can affect the finished height of your chimney system. Other factors can influence the necessary height of the chimney such as “house stack effect” and high altitude.

How far above a chimney should a wood stove be?

Most wood stove and factory-built fireplace manufacturers (and local building codes) will require that “the chimney must extend at least 2 feet above any portion of any structure within 10 feet (measured horizontally) and must extend at least 3 feet above the highest point of its roof penetration.”**. Keep in mind that there is generally ...

What is the length of a roof rise?

Rise is the length, expressed in inches, that the roofline travels upward over a 12-inch horizontal distance, which is known as the run. For example, a common pitch like 4/12 would mean that for every 12 inches of run, the roof rises 4 inches.

Does the 10 and 2 rule apply to pellet vents?

Please note that this rule doesn’t generally apply to pellet and gas vent systems. Hopefully this article helped you understand the 10 and 2 rule but if you still have questions, please leave a comment or send us an email. We are always happy to help.

How far away from outside corner of window should vent be?

OK, if vent is above top of window opening and terminates at least 12" diagonally away from outside corner of window; that would classify as 12" vertically.

How far from windows must vent termination be?

Vent Termination must be at least 9" from windows, doors, or any other opening through which flue gases could enter the building.

How high should a chimney finish?

1. If the top of the chimney is within 600mm (60cm) of the ridge it should finish 60cm higher than the ridge. We also have the “2.3m rule”. These rules helps ensure draft is not spoiled by wind-induced turbulence. 2. Look at the top of your chimney (where the smoke comes out).

How many bends in a chimney?

There must be no bends greater than 45 degrees and there must be no more than four bends in the chimney. If you are using four bends then you must have a soot door between the second and third bend (Building Regs). Note that a “T” off the rear of the stove is classed as two bends (2×45=90).

How to reduce chimney diameter?

To reduce the diameter of a chimney you can line it with a stainless steel “flexi” ( a stove will perform best if the flue diameter of the chimney is as close as possible to that of the stove). One might also use a chimney liner because a brick or stone chimney does not pass a smoke test as required by Building Regulations.

Can you make a chimney with HT pipe?

You can create your own chimney using HT flue pipe (also known as twin-wall flue pipe). See here

Can stainless steel be used in a chimney?

A flexible stainless steel liner should only be used within a structurally sound chimney. It should not be joined along its length (you should not join multiple pieces together to make a length).

Can you connect a stove to a chimney?

If a stove requires a flue of a certain diameter you should never connect it to a chimney that has any section with a diameter less than this. If the stove is DEFRA APPROVED* with a 5″ collar and the stove manufacturer does not state otherwise* then a 5″ liner can be fitted. ** The best way to check this is to download the manufacturer’s fitting ...

What is a chimney connector?

Hunker may earn compensation through affiliate links in this story. The stovepipe, also called a chimney connector, is the component that usually connects the chimney to the stove. When placed through a window, it is meant to exhaust the fumes out of the house. These pipes are often present on wood stoves and an improper installation can be ...

Why do you put a stovepipe through a window?

When placed through a window, it is meant to exhaust the fumes out of the house. These pipes are often present on wood stoves and an improper installation can be a fire hazard. In order to run the stovepipe out of a window, the proper materials and a plan is needed.

How to keep cold air from entering house?

To finish the task, use duct tape to tape the seams running between the window in the metal sheet to keep cold air from entering the house.

How to install a window that won't break?

Open the window so that you can start the installation process. Create enough room so that you can easily maneuver and avoid hitting the glass so that it doesn't break.

How to keep smoke out of a house?

Use the sheet metal screws and the fireproof sealant to secure the connections and make them airtight. This will prevent any smoke from escaping within the house.

What is a chimney connector?

Hunker may earn compensation through affiliate links in this story. The stovepipe, also called a chimney connector, is the component that usually connects the chimney to the stove. When placed through a window, it is meant to exhaust the fumes out of the house. These pipes are often present on wood stoves and an improper installation can be ...

Why do you put a stovepipe through a window?

When placed through a window, it is meant to exhaust the fumes out of the house. These pipes are often present on wood stoves and an improper installation can be a fire hazard. In order to run the stovepipe out of a window, the proper materials and a plan is needed.

How to keep cold air from entering house?

To finish the task, use duct tape to tape the seams running between the window in the metal sheet to keep cold air from entering the house.

How to install a window that won't break?

Open the window so that you can start the installation process. Create enough room so that you can easily maneuver and avoid hitting the glass so that it doesn't break.

How to keep smoke out of a house?

Use the sheet metal screws and the fireproof sealant to secure the connections and make them airtight. This will prevent any smoke from escaping within the house.

image

1.Chimney height rules: Height & Clearance Requirements …

Url:https://inspectapedia.com/chimneys/Chimney_Height_Codes_Specifications.php

23 hours ago If your chimney is two feet above the ridge of a roof over the one story addition, if you can't get more than 12 feet of horizontal distance between chimney and windows of the upper floor, you …

2.chimney distance from windows in The AnswerBank: …

Url:https://www.theanswerbank.co.uk/How-it-Works/Question614283.html

12 hours ago How far does a chimney have to be from a window? If your chimney is two feet above the ridge of a roof over the one story addition, if you can’t get more than 12 feet of horizontal distance …

3.Kitchen Chimney on the window dilemma - Houzz

Url:https://www.houzz.in/discussions/6084089/kitchen-chimney-on-the-window-dilemma

27 hours ago  · How far does a chimney have to be from a window? The top of the flue opening should be at least 10 Ft (3.1 m) away from any roof surface as measured by a horizontal line …

4.Understanding the 10-Foot 2-Foot 3-Foot Rule: How to

Url:https://woodstovepro.com/articles/understanding-the-10-foot-2-foot-3-foot-rule-how-to-determine-the-chimney-height-of-class-a-solid-fuel-pipe-above-the-roofline/

11 hours ago at least 2 Ft (0.61m) above the ridge or above anything within a 10 ft radius (the vertical red line at the left of our photo) The top of the chimney should be. at least 2 ft (0.61m) above the roof …

5.Min. vert. distance from w/h exhaust and operable window

Url:https://forum.nachi.org/t/min-vert-distance-from-w-h-exhaust-and-operable-window/66539

7 hours ago  · This explains all the minimum relevant distances. Now I appreciate it doesn't actually show a roof window (Velux) but the principle about minimum distances from the flue …

6.Regulations and rules for the chimney explained

Url:https://www.stovefitterswarehouse.co.uk/pages/regulations-for-the-chimney

34 hours ago last year. The distance between chimney and hob needs to be 26"-30" : 65cm-80cm. placing it above the window, suction power is reduced, placing it in middle of the window, will make the …

7.How to Run a Stovepipe Out a Window | Hunker

Url:https://www.hunker.com/13402195/how-to-run-a-stovepipe-out-a-window

28 hours ago  · Keep in mind that there is generally a minimum chimney height requirement for the overall system (usually 15 feet, which sometimes includes connector pipe) that can affect the …